Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71514471816 |
ProductName: |
N2K-B22FTS-P |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco N2K-B22FTS-P Full Product Description
1. Short Overview
N2K-B22FTS-Pis a single-width hot-swappable blade Fabric Extender (FEX) within the Cisco Nexus B22 series, custom-engineered for deployment inside Fujitsu PRIMERGY blade server chassis, now End-of-Sale with all official Cisco hardware support expiredCisco. It acts as a stateless remote line card extending the unified fabric of upstream parent Cisco Nexus switches (Nexus 5500 / 5600 / 6000 series; full FCoE support only on N5500/N5600, Ethernet-only operation on Nexus 7000/7700, unsupported on Nexus 9000).
This blade module provides 16 internal fixed 10GBASE-KR midplane host interfaces hardwired to the Fujitsu blade chassis backplane for direct compute node connectivity, paired with 8 external SFP+ 10G fabric uplink ports to connect back to aggregation switches. All control plane logic, Layer 2 forwarding, DCB lossless FCoE, QoS, SAN zoning and security policies are fully centralized, provisioned and enforced on the parent NX-OS switch; the B22FTS-P only handles local packet buffering and traffic tunneling over fabric links without independent local switching capabilitiesCisco.
-
Core suffix definition:-P = Bare blade module without factory pre-installed FET-10G breakout transceivers, differentiated from the pre-populated N2K-B22FTS-F variant that ships with factory loaded FET optics.
-
Key design advantages: Native unified LAN/FCoE convergence for Fujitsu blade racks, fixed mild 2:1 oversubscription ratio, fully powered and cooled by the host Fujitsu blade chassis (no standalone PSU/fan FRUs), zero-touch POAP provisioning and single-pane unified fabric management alongside rack-mount Nexus 2000/2300 FEX devices.
2. Part Number Suffix Breakdown & Cross-Model Comparison
Full PN Breakdown
-
N2K: Cisco Nexus 2000/B22 Blade Fabric Extender product family
-
B22FTS-P: Single-width blade FEX for Fujitsu PRIMERGY blade enclosures
-
B22: Blade form factor Fabric Extender series
-
FTS: Custom hardware tailored exclusively for Fujitsu PRIMERGY blade chassis midplane
-
-P: Bare unpopulated uplink variant, no factory pre-installed SFP+/FET-10G transceivers (customer-supplied uplink optics required)
-
Form factor: Single-width hot-swappable I/O blade slot for Fujitsu PRIMERGY blade chassis; power, cooling and airflow are entirely managed by the blade enclosure infrastructure, no replaceable power/fan modules on the FEX blade itselfCisco.
Hardware Comparison Table
|
Item
|
N2K-B22FTS-P (Bare Fujitsu Blade FEX)
|
N2K-B22FTS-F (Pre-populated FET Variant)
|
N2K-B22DELL-P (Dell Blade FEX)
|
Rack-mount N2K-C23xx Series FEX
|
|
Target Blade Chassis
|
Fujitsu PRIMERGY blade enclosure
|
Fujitsu PRIMERGY blade enclosure
|
Dell M1000e
|
Standard 19-inch rack mount
|
|
Pre-installed Uplink Transceivers
|
None (customer-provided)
|
16 × FET-10G factory preloaded
|
None
|
None
|
|
Internal Host Interfaces
|
16 × fixed 10GBASE-KR midplane
|
16 × fixed 10GBASE-KR midplane
|
16 × 1/10GBASE-KR auto-sense
|
External SFP+/RJ45 ports
|
|
Oversubscription Ratio
|
Fixed 2:1
|
Fixed 2:1
|
Fixed 2:1
|
2:1 / 3:1 / 4:1 model-dependent
|
|
Power & Cooling Source
|
Host Fujitsu blade chassis
|
Host Fujitsu blade chassis
|
Host Dell blade chassis
|
Independent hot-swappable PSU + fan trays
|
|
Primary Use Case
|
Custom uplink optic selection for Fujitsu blade racks
|
Fast mass blade rack deployment with breakout uplinks
|
Dell blade unified fabric access
|
Standalone rack server ToR aggregation
|
Factory Bare Blade Included Hardware
-
Single-width hot-swappable FEX blade module compatible with standard I/O slots of Fujitsu PRIMERGY blade enclosures
-
Hidden internal midplane port bank: 16 × hardwired 10GBASE-KR host interfaces mapped to each Fujitsu blade compute node mezzanine adapter
-
External rear panel port bank: 8 × SFP+ 10G fabric uplink ports for upstream parent Nexus switch interconnection; compatible with FET-10G breakout transceivers, 10G SR/LR/ER optical modules, passive Twinax DAC and active AOC cables
-
Integrated front-panel status LED array: Global system health, fabric uplink link/activity, 16 host port status bank, power fault alarm and UID locator beacon
-
Blade extraction latch, hot-swap handle, hardware installation guide and global safety & regulatory compliance documentation
Items Not Included (Must Be Ordered Separately)
-
SFP+ transceivers for all 8 fabric uplink ports: FET-10G breakout modules, 10G Ethernet SR/LR/ER optical transceivers, passive Twinax copper DAC, active AOC fiber cables
-
Optional accessories: RJ45 serial console rollover cable, out-of-band management Ethernet patch cord
-
Power supplies and fan trays: Fully integrated and supplied by the host Fujitsu PRIMERGY blade chassis, not sold separately with the FEX blade module
-
Feature software licenses: All unified fabric, FCoE and switching features are licensed on the upstream parent Nexus 5500/5600 switch; no dedicated FEX blade licenses required
Supported Parent Switch Platforms
-
Full unified fabric feature set (Ethernet + Lossless FCoE): Cisco Nexus 5500 / 5600 Series (minimum NX-OS 6.0(2)N1(1) firmware release)
-
Partial support (Ethernet only, FCoE disabled): Nexus 6000 / 7000 / 7700 Series
-
Fully unsupported: Nexus 9000 Series (FEX blade FCoE and unified fabric functions disabled)
3. Hardware Port & Slot Layout
Internal Midplane Host Interfaces (Chassis Backplane Side)
16 × fixed 10GBASE-KR midplane host ports hardwired to the Fujitsu PRIMERGY blade chassis backplane, each dedicated to one blade server compute node virtual fabric adapter. Interfaces comply with IEEE 802.3ae 10G Ethernet and IEEE DCB lossless standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) to transport lossless FCoE storage traffic for end-to-end LAN/SAN convergence. All Layer 2 switching, SAN zoning, security ACL and QoS policy enforcement occurs centrally on the parent Nexus switch; no local switching or policy logic exists on the B22FTS-P blade itself.
External Rear Fabric Uplink Ports (Rear Blade Panel)
8 × SFP+ 10G fabric uplink ports for high-density upstream connectivity to parent Nexus aggregation switches. Each SFP+ slot accepts standard single 10G optics or FET-10G breakout transceivers to expand fabric uplink channel count. All eight uplink ports can be bundled into LACP fabric port-channels to support load balancing and full link redundancy, compatible with vPC / FEX vPC high-availability topologies.
Front Blade LED Status Array
Global chassis health LED, individual fabric uplink link/activity indicator LEDs, aggregated status bank for all 16 internal blade host ports, power fault warning LED and UID locator beacon for fast on-site maintenance identification.
4. Hardware Performance Specifications
-
Total host port capacity: 16×10G wire-speed downlink ports, total 160 Gbps aggregate host bandwidth
-
Fabric uplink bandwidth: 8×10G full-duplex uplinks, total 80 Gbps aggregate upstream bandwidth
-
Fixed oversubscription ratio: 2:1 (160G total host bandwidth / 80G total fabric uplink bandwidth)Cisco
-
Full-duplex switching capacity: 160 Gbps; wire-speed forwarding throughput: 297 Mpps (64-byte minimum 64-bit Ethernet frames)
-
Unified shared packet buffer architecture optimized for virtualization, OLTP database and bursty FCoE storage workloads
-
VLAN support: Up to 4094 standard IEEE 802.1Q tagged VLANs, all VLAN configuration managed exclusively on the parent switch
-
Port-channel scaling: Supports up to 8 physical fabric uplink ports per LACP fabric port-channel or vPC trunk
-
Zero-touch provisioning: Automatic firmware image synchronization, configuration download and bulk fleet-wide upgrades triggered via a singleinstall allCLI command on the parent Nexus switch
-
Hardware lossless DCB & offload features (all controlled by parent NX-OS):
-
IEEE 802.1Qbb PFC and 802.1Qaz ETS lossless transport for FCoE over blade midplane links
-
vPC, FEX vPC and Enhanced vPC (EvPC) redundant high-availability fabric topologies
-
PVLAN private VLAN isolation, MSTP multi-instance spanning tree, four-tier hardware QoS per port
-
VNTag virtual machine-aware traffic tagging for multi-tenant blade virtualization environments
-
Jumbo frame support up to 9216-byte MTU for storage and HPC big-data workloads
-
Hardware slow drain detection and buffer credit isolation to eliminate FCoE packet loss under storage traffic bursts
Physical & Environmental Parameters
-
Form Factor: Single-width hot-swappable I/O blade for Fujitsu PRIMERGY blade server enclosures
-
Dimensions: Matches standard single-wide Fujitsu blade I/O module form factor
-
Bare blade module weight: ~1.2 kg (2.6 lbs)
-
Operating temperature range: 10°C ~ 40°C (50°F ~ 104°F); certified altitude up to 3,000 meters (10,000 ft)
-
Storage temperature range: -40°C ~ 60°C (-40°F ~ 140°F)
-
Operating relative humidity: 10%–95% non-condensing; storage humidity 5%–95% non-condensing
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validatedCisco
Power Specifications (Power Fully Supplied by Fujitsu Blade Chassis)
-
Input voltage: 12V DC @ 6A drawn from chassis midplane backplane
-
Typical full-load power consumption: 56W with all 16 host ports active
-
Maximum peak power draw: 70W
-
Heat dissipation: 239 BTU/hour typical full load
-
MTBF: 291,523 hours under standard nominal operating conditionsCisco
5. NX-OS Feature Set (Centrally Managed on Parent Nexus Switch)
Layer 2 Ethernet & Converged FCoE Unified Fabric
-
Single unified management domain; all blade host ports appear as logical HIF (Host Interface) interfaces under the parent NX-OS switch
-
802.1Q VLAN trunking, PVLAN private VLAN isolation (maximum 4094 VLANs)
-
MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for blade server high availability
-
Hardware slow drain detection and buffer credit isolation to mitigate FCoE packet loss on blade midplane links
-
NPV/NPIV FCoE edge virtualization for end-to-end consolidated LAN/SAN blade rack architecture
-
POAP zero-touch automatic provisioning for mass blade chassis FEX deployment fleets
-
Port security, static MAC address locking to block unauthorized blade server traffic access
-
Fixed 10G operation on all internal midplane host ports (no 1G auto-sensing capability unlike Dell B22 variants)
QoS & Traffic Prioritization
-
Four independent hardware priority queues per port (internal 10GBASE-KR host ports and external 10G SFP+ fabric uplinks)
-
Ingress traffic policing, egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built optimized QoS templates for OLTP databases, all-flash NVMe storage, virtual server farms and HPC compute clusters
-
DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over blade midplane interconnects
Monitoring & Automation Tools
-
Cisco DCNM centralized converged fabric monitoring, graphical provisioning and REST API automation
-
Real-time streaming telemetry: port throughput, latency, frame error counters, SFP optical transmit power, granular buffer utilization statistics
-
Fault alert notifications via email, syslog and SNMP v1/v2c/v3
-
GOLD Generic Online Diagnostics for continuous non-disruptive blade hardware health validation
-
Unified bulk firmware upgrade: Single parent switch CLI command upgrades all attached blade and rack FEX devices simultaneously
6. Typical Deployment Scenarios for N2K-B22FTS-P Bare Blade Module
-
Fujitsu PRIMERGY blade rack unified LAN/FCoE access consolidation: Single-wide blade FEX integrates natively inside Fujitsu blade enclosures, consolidating 16 blade virtualization compute nodes and lossless FCoE storage traffic onto a single managed fabric extension blade, eliminating separate external rack access switches for blade infrastructure.
-
Enterprise financial database blade cluster deployments: Mild 2:1 oversubscription ratio and DCB lossless buffer architecture deliver stable low-latency FCoE transport for database blade storage workloads; the bare -P variant allows customers to select custom FET breakout or long-reach LR/ER uplink transceivers to match rack cabling layout requirements.
-
Large-scale standardized Fujitsu blade data center fabric rollout: Hot-swappable single-width blade design enables non-disruptive hardware replacement without power cycling the entire blade chassis; centralized policy management on parent Nexus 5500 switches unifies configuration across blade and rack server access layers.
-
Legacy Fujitsu blade infrastructure unified fabric migration: Transparent 10G blade server upgrade path, retaining existing PRIMERGY chassis hardware while adopting Cisco end-to-end unified FCoE fabric architecture with single-pane NX-OS management.
-
Mid-market multi-tenant blade PoP deployment: Isolate tenant blade server and storage traffic via independent VLAN/VSAN zoning controlled centrally on upstream parent aggregation switches; 8 flexible 10G fabric uplinks support multi-link port-channels for high-bandwidth tenant traffic separation.
7. Standard Package Contents of N2K-B22FTS-P Bare Blade SKU
1 × N2K-B22FTS-P Nexus B22 Blade Fabric Extender bare module (no fabric uplink SFP+/FET transceivers included)
Blade extraction handle, locking latch, hardware installation guide, global safety & regulatory compliance documentation
Separately Mandatory Components (Not Included in This Bare Module Bundle)
-
SFP+ transceivers for all 8 external fabric uplink ports: FET-10G breakout modules, 10G SR/LR/ER optical transceivers, passive Twinax DAC, active AOC fiber cables
-
Optional accessories: RJ45 serial console rollover cable, out-of-band management Ethernet patch cord
-
Power supplies and fan trays: Fully integrated and supplied by the Fujitsu PRIMERGY blade chassis (not sold with the FEX blade module)
-
Feature software licenses: All fabric, routing and FCoE convergence features are licensed on the upstream parent Nexus 5500/5600 switch; no separate FEX blade licenses required
Short Commercial Catalog Summary for Quotation
Cisco N2K-B22FTS-P is an End-of-Sale bare single-width hot-swappable blade Fabric Extender (FEX) from the Cisco Nexus B22 unified fabric platform, purpose-built exclusively for Fujitsu PRIMERGY blade server enclosures, featuring 16 fixed 10GBASE-KR internal midplane host ports supporting Ethernet and lossless DCB FCoE transport, plus 8 external SFP+ 10G fabric uplink ports with a fixed mild 2:1 oversubscription ratio. Distinguished from the pre-populated N2K-B22FTS-F variant, this -P bare blade ships without factory pre-installed FET-10G breakout transceivers, enabling customers to select custom uplink optics based on site cabling infrastructure requirements. This stateless blade module draws all power and cooling from the host Fujitsu blade chassis, with no independent PSU/fan FRUs; all switching, security, QoS and FCoE zoning policies are fully configured, managed and enforced centrally on upstream Cisco Nexus 5500/5600 parent switches. It supports zero-touch POAP provisioning, synchronized bulk firmware upgrades and full vPC high-availability fabric topologies, optimized for unified LAN/FCoE access consolidation inside Fujitsu blade server racks. Limitations include chassis-locked form factor exclusive to Fujitsu PRIMERGY blade enclosures, stateless remote I/O architecture without local switching logic, restricted parent switch compatibility and expired official Cisco hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
|
|
|
| Click:17 Entry Time:2026-07-15 【Print】 【Close】 |
|
|
|
|