   Product Description

Cisco N2K-C2348TQ Full Product Description

1. Short Overview

N2K-C2348TQis a low-power, high-density 1RU 10GBASE-T Fabric Extender (FEX) from the Cisco Nexus 2300 next-generation remote I/O platform, now End-of-Sale with all official Cisco hardware support lifecycles expiredCisco. It functions as a stateless remote port extender paired with upstream parent Nexus switches (N5500/N5600/N6000/N7000/N7700/N9000), delivering 48 auto-sensing 100M/1G/10GBASE-T RJ45 copper host ports plus six flexible 40G QSFP+ fabric uplink ports. All control plane logic, forwarding rules, lossless FCoE, QoS and security policies are fully centralized, configured and enforced on the parent NX-OS switch; the FEX only executes local packet buffering and traffic tunneling across fabric linksCisco.
  • Core platform strengths: Large 32 MB shared dynamic packet buffer for bursty storage/virtualization workloads, low power consumption, dual airflow options (forward/reverse), mild fixed 2:1 oversubscription ratio, 1+1 redundant power supplies and 2+1 redundant hot-swappable fan trays for carrier-grade uptimeCisco.
  • Unique uplink design: 2 dedicated yellow-labeled 40G QSFP+ ports + 4 flexible white-labeled 40G QSFP+ ports; each QSFP+ supports breakout to four independent 10G SFP+ channels, expanding total uplink capacity to 24×10G ports.
  • Copper FCoE capability: Supports lossless Fibre Channel over Ethernet up to 30 meters over CAT6a/CAT7 cabling for unified LAN/SAN convergence.

2. Part Number Suffix Breakdown & Model Differentiation

Full PN Breakdown

  1. N2K: Nexus 2000/2300 Series Fabric Extender product family
  2. C2348TQ: 1RU high-density low-power copper FEX chassis model
    • 48 × auto-negotiating 100M/1G/10GBASE-T RJ45 host ports
    • T = 10GBASE-T copper host interfaces;Q = Six integrated 40G QSFP+ fabric uplink ports (mix dedicated + flexible slots)
  3. No fixed airflow preset: Power supply and fan trays are ordered separately to select port-side exhaust (forward airflow) or port-side intake (reverse airflow) cooling directionCisco.

Key Hardware Comparison vs N2K-C2332TQ

表格
Item N2K-C2348TQ N2K-C2332TQ
Copper Host Ports 48 × 100M/1/10GBASE-T 32 × 100M/1/10GBASE-T
Total 40G QSFP+ Uplinks 6 ports (2 dedicated + 4 flexible) 4 fixed 40G QSFP+ ports
Max Aggregate Upstream Bandwidth 240 Gbps 160 Gbps
Max Breakout 10G Uplink Count 24 × 10G 16 × 10G
Oversubscription Ratio Fixed 2:1 Fixed 2:1
Shared Packet Buffer 32 MB configurable dynamic buffer 32 MB configurable dynamic buffer
Typical Full Load Power Draw ~280W ~190W
Chassis Depth Deeper 433.6mm Shallow 356.9mm

Factory Bare Chassis Included Hardware

  1. 1RU standard 19-inch EIA horizontal rack-mount passive chassis
  2. Rear panel fixed port bank:
    • 48 × auto-sensing 100M/1G/10GBASE-T RJ45 copper host ports for virtualization servers, blade servers and entry all-flash storage
    • 6 × 40G QSFP+ fabric uplink ports: 2 yellow dedicated uplinks, 4 white flexible multi-purpose uplinks for parent switch interconnection; each QSFP+ port supports breakout splitter cables to 4×10G SFP+ channels
  3. Front panel redundant FRU slots: Dual AC power supply bays, three hot-swappable fan tray slots (2+1 cooling redundancy)
  4. Integrated out-of-band management suite: HDMI RJ45 hybrid serial console, dual 10/100/1000BASE-T out-of-band management Ethernet, USB Type-A diagnostic flash port
  5. Full status LED indicators: Global system health, individual power supply fault, fan tray fault, per-port link/activity, UID rack locator beacon
  6. Standard 19-inch rack mounting rails, front cable management brackets, hardware installation guide and global safety compliance documentation

Items Not Included (Must Be Ordered Separately)

  • Hot-swappable AC power supplies (single PSU for basic operation, dual PSUs mandatory for 1+1 N+1 power redundancy; airflow must match fan tray direction)
  • Three hot-swappable fan trays (2+1 redundant cooling; mismatched airflow directions trigger thermal protection shutdown)
  • 40G QSFP+ transceivers, BiDi optical modules, active Twinax DAC, active AOC and 40G-to-4×10G breakout splitter cables for six fabric uplink ports
  • Optional accessories: Lockable front door, air filter panel, airflow optimization sleeve, serial console rollover cable

Supported Parent Switch Platforms

Nexus 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releases (FCoE functionality restricted to N5K/N6K/N7K platforms, not supported on Nexus 9000).

3. Hardware Port & Slot Layout

Rear Panel Fixed Ports

  1. 48 × 100M/1G/10GBASE-T RJ45 Host Ports
    Triple-speed auto-sensing copper interfaces compliant with IEEE 802.3an 10GBASE-T and IEEE DCB lossless standards (802.1Qbb PFC, 802.1Qaz ETS). Delivers lossless FCoE transmission over CAT6a/CAT7 cabling with maximum 30-meter reach. All Layer 2 switching, SAN and security policies are enforced centrally on the parent switch rather than the FEX itself.
  2. 6 × 40G QSFP+ Fabric Uplink Ports (2 Yellow / 4 White Labeled)
    Wire-speed 40G Ethernet/FCoE uplinks for high-capacity leaf-spine fabric connectivity to upstream parent aggregation/spine switches. Each QSFP+ port breaks out to four independent 10G channels via dedicated splitter cables, expanding total uplink 10G capacity to 24 ports. All six uplinks can be bundled into LACP port-channels for load balancing and full link failure redundancy; BiDi optics support reuse of existing single-fiber rack cabling infrastructureCisco.

Front Panel Redundant FRU Slots

  1. Two independent hot-swappable AC power supply bays (1+1 redundant deployment supported for non-stop production operation)
  2. Three independent hot-swappable fan tray slots (2+1 N+1 cooling architecture eliminates single cooling failure points)

Front Panel LED Status Array

Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 48 RJ45 host ports and six 40G QSFP+ uplink ports, UID locator beacon for fast rack asset identification during maintenance.

4. Hardware Performance Specifications

  1. Total host port capacity: 48×10G wire-speed downlink ports, total 480 Gbps aggregate host bandwidth
  2. Fabric uplink bandwidth: 6×40G full-duplex uplinks, total 240 Gbps aggregate upstream bandwidth
  3. Fixed oversubscription ratio: 2:1 (480G host bandwidth / 240G uplink bandwidth)Cisco
  4. Full-duplex switching capacity: 480 Gbps; wire-speed forwarding throughput: 2160 Mpps (64-byte minimum frame size)Cisco
  5. Dynamic shared packet buffer: 32 MB user-configurable shared buffer, optimized for bursty virtualization, OLTP database, big-data and FCoE storage workloads
  6. VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
  7. Port-channel scaling: Supports up to 16 physical host ports per LACP host port-channel / vPC trunk
  8. Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk firmware upgrades triggered via a singleinstall allcommand on the parent switch
  9. Hardware offload & lossless features (controlled by parent NX-OS):
    • IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE transport over copper host ports
    • vPC dual-homing, PVLAN private VLAN, MSTP multi-instance spanning tree, four-level hardware QoS traffic classification per port
    • VNTag virtual machine-aware traffic tagging for multi-tenant virtualized environments
    • Jumbo frame support up to 9216-byte MTU for storage and big-data workloads
    • Expanded buffer utilization and granular drop debug counters for storage burst troubleshooting

Physical & Environmental Parameters

  • Form Factor: 1 RU (43.7 mm height), standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 43.7 mm × 439.4 mm × 433.6 mm (1.72 × 17.3 × 17.07 inches)
  • Bare chassis weight (no PSUs/fans/transceivers): ~8.0 kg (17.6 lbs)
  • Fully loaded maximum weight (dual PSUs + three fans + full transceivers): ~10.2 kg (22.5 lbs)
  • Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
  • Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
  • Operating relative humidity: 8%–80% non-condensing; storage humidity 5%–95% non-condensing
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated

AC Power Supply FRU Specifications (Sold Separately)

  • Input: Universal 90–264V AC, 47–63Hz
  • Typical full-load power consumption: 280W with all 48 host ports active; maximum 330W peak power draw
  • Hot-swappable OIR replacement, supports 1+1 redundant power deployment

5. NX-OS Feature Set (Managed Centrally on Parent Switch)

Layer 2 Ethernet & Converged FCoE Fabric

  • Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
  • 802.1Q VLAN tagging, PVLAN private VLAN isolation (max 4094 VLANs)
  • MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
  • Hardware slow drain detection and buffer credit isolation to eliminate FCoE packet loss over copper host ports
  • NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
  • POAP zero-touch automatic provisioning for mass rack FEX deployment
  • Port security, static MAC locking to restrict unauthorized server/storage device attachment
  • Auto-sensing 100M/1G/10G operation on all RJ45 host ports without transceiver replacement

QoS & Traffic Prioritization

  • Four hardware priority queues per port (10GBASE-T copper and 40G QSFP+ uplinks)
  • Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
  • Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, virtual server farms and big-data clusters
  • DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over CAT6a/CAT7 copper cabling

Monitoring & Automation Tools

  • Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
  • Real-time streaming telemetry: port throughput, latency, frame error counters, QSFP optical transmit power, detailed buffer utilization statistics
  • Fault alert notifications via email, syslog and SNMP v1/v2c/v3
  • GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
  • Unified bulk firmware upgrade: Single CLI command on parent switch upgrades all attached FEX devices simultaneously

6. Typical Deployment Scenarios for N2K-C2348TQ Bare Chassis

  1. High-density virtualized leaf-spine data center ToR expansion: 48-port 10G copper design reuses existing CAT6a cabling for dense virtualization server racks; six flexible 40G uplinks deliver mild 2:1 oversubscription, ideal for latency-sensitive database and storage workloads requiring abundant uplink bandwidth and redundancy
  2. Medium enterprise unified LAN/FCoE storage rack: Low-power 2300-series architecture reduces rack power draw, supporting lossless FCoE over copper for medium-scale all-flash storage arrays without costly all-fiber infrastructure
  3. Blade server rack high-density access extension: Compact 1RU form factor pairs with multi-blade server enclosures, expanding 10G copper port density while preserving high-value 40G uplink ports on upstream parent spine switches
  4. Legacy Gigabit data center migration path: Smooth transition from 1G to 10G server access, retaining existing structured copper cabling and single-pane unified fabric management on upstream Nexus parent switches
  5. Medium multi-tenant service provider PoP leaf access: High-density 10G copper rack-level port expansion with complete VLAN/VSAN tenant isolation controlled centrally on the upstream core parent switch; flexible six 40G uplinks support multi-link port-channels for tenant traffic separation

7. Standard Package Contents of N2K-C2348TQ Bare Chassis SKU

1 × N2K-C2348TQ Nexus 2348TQ 1RU Fabric Extender bare chassis (no power supplies, fan trays or QSFP+ transceivers)
19-inch standard rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation

Separately Mandatory Components (Not Included in This Bare Chassis Bundle)

  • One or two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy, airflow matched to fan trays)
  • Three matching airflow hot-swappable fan trays (three fans required for 2+1 cooling redundancy; airflow must align with power supplies to avoid thermal protection faults)
  • 40G QSFP+ transceivers, BiDi optics, Twinax DAC breakout splitter cables for six fabric uplink QSFP+ ports
  • Optional feature software licenses: All fabric, routing and storage features are licensed on the upstream parent Nexus switch; no separate FEX licenses required
  • HDMI serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, lockable front door, air filter panel

Short Commercial Catalog Summary for Quotation

Cisco N2K-C2348TQ is an End-of-Sale bare low-power 1RU high-density 10G copper Fabric Extender (FEX) from the next-gen Nexus 2300 remote I/O platform, featuring 48 fixed auto-sensing 100M/1/10GBASE-T RJ45 host ports plus six integrated flexible 40G QSFP+ fabric uplink ports expandable to 24×10G breakout uplink channels, with a fixed mild 2:1 oversubscription ratio and large 32 MB configurable dynamic packet buffer optimized for bursty storage, database and virtualization workloads. This stateless bare chassis does not include power supplies, fan trays or transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It supports dual airflow configurations (port-side intake / port-side exhaust) for flexible hot/cold aisle rack layouts, lossless FCoE transport over CAT6a/CAT7 copper up to 30 meters via IEEE DCB standards, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for high-density virtualized leaf-spine data center top-of-rack expansion and medium enterprise unified LAN/SAN deployments requiring abundant 10G copper server ports and flexible high-capacity 40G uplinks, limited by copper-only host port design, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.