Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
71511513616
ProductName:
N2K-C2248PQ-10GE
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco N2K-C2248PQ-10GE Full Product Description

1. Short Overview

N2K-C2248PQ-10GEis a compact 1RU high-density all-fiber Fabric Extender (FEX) from Cisco Nexus 2000 Series, a stateless remote I/O device that extends high-density 1/10G SFP+ port capacity for upstream parent Nexus switches (N5000/N5500/N5600/N6000/N7000/N9000)Cisco. It delivers 48 auto-sensing 1/10G SFP+ host downlinks for blade servers, all-flash storage and virtualized compute nodes, paired with four native 40G QSFP+ fabric uplink ports. Each 40G QSFP+ port supports breakout to four independent 10G SFP+ channels via splitter cables, expanding total fabric uplink capacity to 16×10G ports. All control plane logic, forwarding policies, lossless FCoE, QoS and security rules are fully centralized and managed on the parent NX-OS switch; the FEX only performs local packet buffering and traffic tunneling over fabric links. The Nexus 2248PQ-10GE platform has reached End-of-Sale, and all official Cisco hardware support lifecycles have expiredCisco.
  • Core all-fiber design: No built-in copper RJ45 ports; all host and uplink interfaces use SFP+/QSFP+ transceivers for flexible short/long-reach fiber and Twinax DAC deployments
  • Dual airflow flexibility: Port-side intake (blue handle) or port-side exhaust (red handle) power/fan FRUs to match any hot/cold aisle rack layout; airflow direction of all power and fan modules must be consistent to avoid thermal protection shutdownManualsLib
  • Fixed 3:1 maximum oversubscription ratio: 480 Gbps aggregate host bandwidth vs 160 Gbps total fabric uplink bandwidth
  • Carrier-grade redundancy: Hot-swappable dual AC power supplies and dual fan trays for non-stop production operation

2. Part Number Suffix Breakdown

  1. N2K: Nexus 2000 Series Fabric Extender product family
  2. C2248PQ-10GE: 1RU high-density all-fiber FEX chassis model
    • 48 × auto-sensing 1/10G SFP+ host ports for server/storage attachment
    • P: Dense SFP+ host port bank;Q: Four native 40G QSFP+ fabric uplink ports (breakout to 4×10G per port)
    • 10GE: All ports natively support wire-speed 10G Ethernet and lossless FCoE transport
  3. No fixed airflow preset: Power supply and fan trays are ordered separately to define chassis cooling directionManualsLib

Factory Bare Chassis Included Hardware

  1. 1RU standard 19-inch EIA horizontal rack-mount passive chassis
  2. Rear panel fixed port bank:
    • 48 × auto-negotiating 1/10G SFP+ host ports for server, virtualization host and all-flash storage connections
    • 4 × yellow-labeled QSFP+ 40G fabric uplink ports dedicated to parent switch interconnectionManualsLib
  3. Front panel redundant FRU slots: Dual AC power supply bays, dual hot-swappable fan tray slots
  4. Integrated status LED indicators: Global system health, power supply fault, fan fault, per-port link/activity, UID rack locator beacon
  5. Complete out-of-band management suite: RJ45 RS232 serial console, dual 10/100/1000BASE-T out-of-band management Ethernet, USB Type-A diagnostic flash port
  6. Standard 19-inch rack mounting rails, front cable management brackets, hardware installation & global safety compliance documentation

Items Not Included (Must Be Ordered Separately)

  • Hot-swappable AC power supplies (single PSU for basic operation, dual PSUs for N+1 power redundancy; airflow matched to fan trays)
  • Hot-swappable fan trays (single fan for basic operation, dual fans for redundant cooling; airflow must align with power supplies)
  • SFP+ transceivers, Twinax copper DAC cables, active AOC cables for all 48 host SFP+ ports
  • QSFP+ 40G transceivers, 40G-to-4×10G breakout splitter cables for four fabric uplink ports
  • Optional accessories: Lockable front door, air filter panel, cable management guides, serial console rollover cable

Supported Parent Switch Platforms

All Nexus 5000, 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releases (minimum NX-OS 6.0(2)N1(1) for N5K/N6K)Cisco.

3. Hardware Port & Slot Layout

Rear Panel Fixed Ports

  1. 48 × 1/10G SFP+ Host Ports
    Auto-sensing 1G/10G fiber interfaces compliant with IEEE 802.3ae 10G Ethernet and IEEE DCB lossless standards (802.1Qbb PFC, 802.1Qaz ETS) to carry lossless FCoE storage traffic over multi-mode/single-mode fiber or short-range Twinax DAC cables. Each SFP+ slot supports standard Ethernet transceivers and Fibre Channel SFP+ transceivers for direct disk array, all-flash storage and tape library SAN attachment. All Layer 2, SAN and security policies are enforced centrally on the parent switch, not the FEX itselfCisco.
  2. 4 × QSFP+ 40G Fabric Uplink Ports (Yellow Labeled)
    Wire-speed 40G Ethernet/FCoE uplinks for fabric connectivity to the upstream parent spine/aggregation switch. Each QSFP+ port supports breakout via splitter cables into four independent 10G SFP+ channels, expanding total fabric uplink capacity to 16×10G ports. All four uplinks can be bundled into LACP port-channels for load balancing and full link failure redundancyCisco.

Front Panel Redundant FRU Slots

  1. Two independent hot-swappable AC power supply bays (N+1 redundant deployment supported)
  2. Two independent hot-swappable fan tray slots (dual-fan redundancy eliminates single cooling point of failure)

Front Panel LED Status Array

Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 48 host SFP+ and four 40G QSFP+ uplink ports, UID locator beacon for quick rack asset identification.

4. Hardware Performance Specifications

  1. Total host port capacity: 48×10G wire-speed downlink ports, total 480 Gbps aggregate host bandwidth
  2. Fabric uplink bandwidth: 4×40G full-duplex uplinks, total 160 Gbps aggregate upstream bandwidth
  3. Fixed oversubscription ratio: 3:1 (480G host bandwidth / 160G uplink bandwidth)
  4. Full-duplex switching capacity: 1280 Gbps; wire-speed Layer 2/Layer 3 forwarding throughput: 952 Mpps (64-byte minimum frame size)
  5. Split dynamic packet buffer: 32 MB ingress buffer (network-to-host) + 8 MB egress buffer (host-to-network), optimized for bursty virtualization, big-data and FCoE storage workloads
  6. VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
  7. Port-channel scaling: Supports up to 16 physical host ports per LACP host port-channel / vPC trunk
  8. Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk upgrades triggered from a singleinstall allcommand on the parent switch
  9. Hardware offload & lossless features (controlled by parent NX-OS):
    • IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE storage transport
    • vPC dual-homing, PVLAN private VLAN, MSTP spanning tree, QoS traffic classification
    • VNTag virtual machine-aware traffic tagging for virtualized server environments
    • Buffer-to-buffer credits for medium-distance Fibre Channel SAN extension via SFP+ FC transceivers
    • Jumbo frame support up to 9216-byte MTU for storage and big-data workloadsCisco

Physical & Environmental Parameters

  • Form Factor: 1 RU (43.7 mm height), standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 43.7 mm × 439.4 mm × 449.6 mm (1.72 × 17.3 × 17.7 inches)
  • Bare chassis weight (no PSUs/fans/transceivers): ~6.2 kg (13.7 lbs)
  • Fully loaded maximum weight (dual PSUs + four fans + full transceivers): ~8.0 kg (17.6 lbs)
  • Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
  • Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
  • Operating relative humidity: 5%–80% non-condensing; storage humidity 5%–95% non-condensing
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated

AC Power Supply FRU Specifications (Sold Separately)

  • Input: Universal 90–264V AC, 47–63Hz
  • Typical full-load power consumption: 230W with all 48 host ports active
  • Hot-swappable OIR replacement, supports N+1 redundant power deployment

5. NX-OS Feature Set (Managed Centrally on Parent Switch)

Layer 2 Ethernet & Converged FCoE Fabric

  • Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
  • 802.1Q VLAN tagging, PVLAN private VLAN isolation
  • MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
  • Hardware slow drain detection and buffer credit isolation to eliminate FCoE storage packet loss
  • NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
  • POAP zero-touch automatic provisioning for mass rack FEX deployment
  • Port security, static MAC locking to restrict unauthorized server/storage device attachment
  • Full 1/10G auto-sensing on all SFP+ host ports without transceiver replacement

QoS & Traffic Prioritization

  • Four hardware priority queues per port (all SFP+ host and 40G QSFP+ uplink ports)
  • Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
  • Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, HPC big-data clusters and virtual server farms
  • DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over fiber and Twinax copper DAC interfaces

Monitoring & Automation Tools

  • Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
  • Real-time streaming telemetry: port throughput, latency, frame error counters, SFP/QSFP optical transmit power diagnostics
  • Fault alert notifications via email, syslog and SNMP traps
  • GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
  • Unified bulk firmware upgrade: Single command on parent switch upgrades all attached FEX devices simultaneously

6. Typical Deployment Scenarios for N2K-C2248PQ-10GE Bare Chassis

  1. Large leaf-spine all-fiber data center leaf rack: 48 SFP+ 10G host ports connect high-density virtualization servers, blade enclosures and all-flash storage arrays; four 40G QSFP+ uplinks deliver high-capacity low-oversubscription connectivity to the spine layer, ideal for high-throughput virtualized workloadsCisco
  2. Enterprise financial/mainframe unified long-distance SAN-LAN rack: All-fiber design supports LR/ER SFP+ transceivers for cross-building SAN replication, consolidating 10G virtual server links and Fibre Channel storage on a single compact 1RU FEX chassis
  3. High-performance computing (HPC) / distributed storage rack aggregation: Large split ingress buffer absorbs massive burst traffic from compute clusters and distributed file systems, avoiding FCoE packet loss under heavy load
  4. Legacy Nexus fabric high-density fiber upgrade: Direct replacement for N2K-C2232PP-10GE to boost host port count and uplink bandwidth; backward compatible with existing 10G SFP transceivers and all supported parent switch platforms
  5. Medium multi-tenant service provider multi-tenant PoP leaf switch: High-density fiber port design isolates tenant traffic via VLAN/VSAN, with centralized security and QoS policy control on the upstream core parent switch

7. Standard Package Contents of N2K-C2248PQ-10GE Bare Chassis SKU

1 × N2K-C2248PQ-10GE Nexus 2248PQ 1RU Fabric Extender bare chassis (no power supplies, fan modules or transceivers)
19-inch standard 19-inch rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation

Separately Mandatory Components (Not Included in This Bare Chassis Bundle)

  • Two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy, airflow matched to fan trays)
  • Two matching airflow hot-swappable fan trays (dual fans recommended for cooling redundancy; airflow must align with power supplies to avoid thermal faults)
  • SFP+/SFP optical transceivers and Twinax DAC copper cables for all 48 host SFP+ ports
  • QSFP+ 40G transceivers and 4×10G breakout splitter cables for four fabric uplink QSFP+ ports
  • Optional feature software licenses: All fabric, routing and storage features are licensed on the upstream parent Nexus switch; no separate FEX licenses required
  • RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, lockable front door, air filter panel

Short Commercial Catalog Summary for Quotation

Cisco N2K-C2248PQ-10GE is an End-of-Sale bare 1RU high-density all-fiber Fabric Extender (FEX) from the third-generation Nexus 2000 data center remote I/O platform, featuring 48 fixed auto-sensing 1/10G SFP+ fiber host ports (native Ethernet/FCoE and support for Fibre Channel transceivers) plus four native 40G QSFP+ fabric uplink ports expandable to 16 total wire-speed 10G uplink channels via breakout cables, with a fixed 3:1 oversubscription ratio and split 32MB ingress / 8MB egress dynamic packet buffer optimized for bursty storage, HPC and virtualization workloads. This stateless bare chassis does not include power supplies, fan trays or transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It supports dual airflow configurations (port-side intake / port-side exhaust) for flexible hot/cold aisle rack layouts, lossless FCoE transport via IEEE DCB standards, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for large-scale leaf-spine data center leaf aggregation and enterprise financial unified SAN/LAN deployments requiring high-density all-fiber 10G host ports and 40G spine uplinks, limited by fiber-only host port design, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
Click:19 Entry Time:2026-07-15 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联