   Product Description

Cisco N2K-C2248PQ Full Product Description

1. Short Overview

N2K-C2248PQis a high-density all-fiber 1RU Fabric Extender (FEX) from Cisco Nexus 2000 Series, a stateless remote I/O device designed for leaf-spine 10G/40G converged data center, virtualization and unified LAN/FCoE storage environmentsCisco. It delivers 48×1/10G SFP+ host downlinks for blade servers, all-flash storage and high-performance compute nodes, paired with four wire-speed 40G QSFP+ fabric uplink ports. Each 40G QSFP+ port can break out to four independent 10G SFP+ channels, expanding total fabric uplink capacity to 16×10G ports. All control plane logic, forwarding rules, QoS, lossless FCoE and security policies are fully centralized and managed on upstream parent Nexus switches (N5000/N5500/N5600/N6000/N7000/N9000). This platform has reached End-of-Sale with all official Cisco hardware support lifecycles expired.
  • Core design advantages: All SFP+ fiber host ports with native FCoE capability, high-capacity 40G breakout uplinks, split ingress/egress large packet buffers, dual airflow options for flexible hot/cold aisle rack deployment
  • Fixed 3:1 oversubscription ratio: 480 Gbps aggregate host bandwidth vs 160 Gbps total fabric uplink bandwidth
  • Carrier-grade redundancy: Hot-swappable dual AC power supplies and dual hot-swappable fan trays to eliminate single power/cooling failure points

2. Part Number Suffix Breakdown & Model Differentiation

Full PN Breakdown

  1. N2K: Nexus 2000 Series Fabric Extender product family
  2. C2248PQ: 1RU high-density all-fiber FEX chassis
    • 48 × auto-sensing 1/10G SFP+ host ports (supports Ethernet and lossless FCoE)
    • P: Dense SFP+ host port bank;Q: Four native 40G QSFP+ fabric uplink ports (breakout to 4×10G per port)
  3. No fixed airflow preset: Power supply and fan trays are ordered separately with matching port-side intake / port-side exhaust airflow directions

Key Hardware Comparison vs N2K-C2232PP-10GE

表格
Item N2K-C2248PQ N2K-C2232PP-10GE
Host SFP+ Ports 48 × 1/10G 32 × 1/10G
Fabric Uplinks 4 × 40G QSFP+ (16×10G breakout) 8 × 10G SFP+
Aggregate Uplink Bandwidth 160 Gbps 80 Gbps
Oversubscription Ratio Fixed 3:1 Fixed 4:1
Packet Buffer 32 MB ingress / 8 MB egress split buffer Single 8 MB shared buffer
Deployment Focus High-density all-fiber rack leaf with 40G spine uplinks Medium-density all-fiber rack with 10G-only uplinks

Factory Bare Chassis Included Hardware

  1. 1RU standard 19-inch EIA horizontal rack-mount passive chassis
  2. Rear panel fixed port bank:
    • 48 × auto-negotiating 1/10G SFP+ host ports for server, virtualization host and all-flash storage connections
    • 4 × yellow-labeled 40G QSFP+ fabric uplink ports dedicated to parent switch interconnection
  3. Front panel redundant FRU slots: Dual AC power supply bays, dual hot-swappable fan tray slots
  4. Complete out-of-band management interfaces: RJ45 RS232 serial console, dual 10/100/1000BASE-T out-of-band management Ethernet, USB Type-A diagnostic flash port
  5. Integrated status LED indicators: Global system health, power supply fault, fan fault, per-port link/activity, UID rack locator beacon
  6. Standard 19-inch rack mounting rails, front cable management brackets, hardware installation & global safety compliance documentation

Items Not Included (Must Be Ordered Separately)

  • Hot-swappable AC power supplies (minimum two for N+1 redundancy; airflow must match fan trays)
  • Dual hot-swappable fan trays (airflow direction consistent with power supplies to avoid thermal protection shutdown)
  • SFP+ transceivers, Twinax copper DAC, active AOC cables for all 48 host SFP+ ports
  • QSFP+ 40G transceivers, 40G-to-4×10G breakout splitter cables for four fabric uplink ports
  • Optional accessories: Lockable front door, air filter panel, cable management guides, serial console rollover cable

Supported Parent Switch Platforms

Nexus 5000, 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releases (minimum NX-OS 6.0(2)N1(1) for N5K/N6K).

3. Hardware Port & Slot Layout

Rear Panel Fixed Ports

  1. 48 × 1/10G SFP+ Host Ports
    Auto-sensing 1G/10G fiber interfaces compliant with IEEE 802.3ae 10G Ethernet and IEEE DCB lossless standards (802.1Qbb PFC, 802.1Qaz ETS) to carry lossless FCoE storage traffic over multi-mode/single-mode fiber or short-range Twinax DAC cables. All Layer 2, SAN and security policies are enforced centrally on the parent switch, not the FEX itself. Each SFP+ slot supports standard Ethernet transceivers and Fibre Channel SFP+ transceivers for direct SAN storage attachment.
  2. 4 × 40G QSFP+ Fabric Uplink Ports
    Wire-speed 40G Ethernet/FCoE uplinks for high-capacity fabric connectivity to the upstream parent spine/aggregation switch. Each QSFP+ port supports breakout via splitter cables into four independent 10G SFP+ channels, expanding total fabric uplink capacity to 16×10G ports. All four uplinks can be bundled into LACP port-channels for load balancing and full link redundancy.

Front Panel Redundant FRU Slots

  1. Two independent hot-swappable AC power supply bays (N+1 redundant deployment supported)
  2. Two independent hot-swappable fan tray slots (dual-fan redundancy eliminates single cooling point of failure)

Front Panel LED Status Array

Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 48 host SFP+ and four 40G QSFP+ uplink ports, UID locator beacon for quick rack asset identification.

4. Hardware Performance Specifications

  1. Total host port capacity: 48×10G wire-speed downlink ports, total 480 Gbps aggregate host bandwidth
  2. Fabric uplink bandwidth: 4×40G full-duplex uplinks, total 160 Gbps aggregate upstream bandwidth
  3. Fixed oversubscription ratio: 3:1 (480G host bandwidth / 160G uplink bandwidth)
  4. Full-duplex switching capacity: 1280 Gbps; wire-speed forwarding throughput: 952 Mpps (64-byte minimum frame size)
  5. Split dynamic packet buffer: 32 MB ingress buffer (network-to-host) + 8 MB egress buffer (host-to-network), optimized for bursty virtualization and FCoE storage workloads
  6. VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
  7. Port-channel scaling: Supports up to 16 physical host ports per LACP host port-channel / vPC trunk
  8. Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk upgrades triggered from a singleinstall allcommand on the parent switch
  9. Hardware offload & lossless features (controlled by parent NX-OS):
    • IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE storage transport
    • vPC dual-homing, PVLAN private VLAN, MSTP spanning tree, QoS traffic classification
    • VNTag virtual machine-aware traffic tagging for virtualized server environments
    • Buffer-to-buffer credits for medium-distance Fibre Channel SAN extension via SFP+ FC transceivers
    • Jumbo frame support up to 9216-byte MTU for storage and big-data workloads

Physical & Environmental Parameters

  • Form Factor: 1 RU (43.7 mm height), standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 43.7 mm × 439.4 mm × 449.6 mm (1.72 × 17.3 × 17.7 inches)
  • Bare chassis weight (no PSUs/fans/transceivers): ~6.2 kg (13.7 lbs)
  • Fully loaded maximum weight (dual PSUs + dual fans + full transceivers): ~8.0 kg (17.6 lbs)Cisco Russ...
  • Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
  • Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
  • Operating relative humidity: 5%–95% non-condensing
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated

AC Power Supply FRU Specifications (Sold Separately)

  • Input: Universal 90–264V AC, 50–63Hz
  • Typical full-load power consumption: 230W with all 48 host ports active
  • Hot-swappable OIR replacement, supports N+1 redundant power deployment

5. NX-OS Feature Set (Managed Centrally on Parent Switch)

Layer 2 Ethernet & Converged FCoE Fabric

  • Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
  • 802.1Q VLAN tagging, PVLAN private VLAN isolation
  • MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
  • IEEE DCB lossless standards (PFC, ETS) enabling FCoE storage traffic over all SFP+ fiber host ports
  • NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
  • POAP zero-touch automatic provisioning for mass rack FEX deployment
  • Port security, static MAC locking to restrict unauthorized server/storage device attachment
  • Full 1/10G auto-sensing on all SFP+ host ports without transceiver replacement

QoS & Traffic Prioritization

  • Four hardware priority queues per port (all SFP+ host and 40G QSFP+ uplink ports)
  • Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
  • Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, HPC big-data clusters and virtual server farms
  • DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over fiber and Twinax copper DAC interfaces

Monitoring & Automation Tools

  • Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
  • Real-time streaming telemetry: port throughput, latency, frame error counters, SFP/QSFP optical transmit power diagnostics
  • Fault alert notifications via email, syslog and SNMP traps
  • GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
  • Unified bulk firmware upgrade: Single command on parent switch upgrades all attached FEX devices simultaneously

6. Typical Deployment Scenarios for N2K-C2248PQ Bare Chassis

  1. Large leaf-spine all-fiber data center leaf rack: 48 SFP+ 10G host ports connect high-density virtualization servers, blade enclosures and all-flash storage arrays; four 40G QSFP+ uplinks deliver high-capacity low-oversubscription connectivity to the spine layer, ideal for high-throughput virtualized workloads
  2. Enterprise financial/mainframe unified long-distance SAN-LAN rack: All-fiber design supports LR/ER SFP+ transceivers for cross-building SAN replication, consolidating 10G virtual server links and Fibre Channel storage on a single compact 1RU FEX chassis
  3. High-performance computing (HPC) / distributed storage rack aggregation: Large split ingress buffer absorbs massive burst traffic from compute clusters and distributed file systems, avoiding FCoE packet loss under heavy load
  4. Legacy Nexus fabric high-density fiber upgrade: Direct replacement for N2K-C2232PP-10GE to boost host port count and uplink bandwidth; backward compatible with existing 10G SFP transceivers and all supported parent switch platforms
  5. Medium multi-tenant service provider PoP leaf switch: High-density fiber port design isolates tenant traffic via VLAN/VSAN, with centralized security and QoS policy control on the upstream core parent switch

7. Standard Package Contents of N2K-C2248PQ Bare Chassis SKU

1 × N2K-C2248PQ Nexus 2248PQ 1RU Fabric Extender bare chassis (no power supplies, fan trays or transceivers)
19-inch standard rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation

Separately Mandatory Components (Not Included in This Bare Chassis Bundle)

  • Two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy, airflow matched to fan trays)
  • Two matching airflow hot-swappable fan trays (dual fans recommended for cooling redundancy; airflow must align with power supplies to avoid thermal faults)
  • SFP+ optical transceivers, Twinax DAC copper cables and FET-10G transceivers for all 48 host SFP+ ports
  • QSFP+ 40G transceivers and 4×10G breakout splitter cables for four fabric uplink QSFP+ ports
  • Optional feature software licenses: All fabric, routing and storage features are licensed on the upstream parent Nexus switch; no separate FEX licenses required
  • RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, lockable front door, air filter panel

Short Commercial Catalog Summary for Quotation

Cisco N2K-C2248PQ is an End-of-Sale bare 1RU high-density all-fiber Fabric Extender (FEX) from the Nexus 2000 remote I/O platform, featuring 48 fixed auto-sensing 1/10G SFP+ fiber host ports (native Ethernet/FCoE) plus four 40G QSFP+ fabric uplink ports expandable to 16×10G breakout uplink channels, with a fixed 3:1 oversubscription ratio and split 32MB ingress / 8MB egress dynamic packet buffer optimized for bursty storage and virtualization workloads. This stateless bare chassis does not include power supplies, fan trays or transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It supports dual airflow configurations (port-side intake / port-side exhaust) for flexible hot/cold aisle rack layouts, lossless FCoE transport via IEEE DCB standards, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for large-scale all-fiber leaf-spine data center leaf aggregation and enterprise financial unified SAN/LAN deployments requiring high-density 10G host ports and 40G spine uplinks, limited by fiber-only host port design, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
Click:33 Entry Time:2026-07-15 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联