Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71511464816 |
ProductName: |
N2K-C2248PQ |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco N2K-C2248PQ Full Product Description
1. Short Overview
N2K-C2248PQis a high-density all-fiber 1RU Fabric Extender (FEX) from Cisco Nexus 2000 Series, a stateless remote I/O device designed for leaf-spine 10G/40G converged data center, virtualization and unified LAN/FCoE storage environmentsCisco. It delivers 48×1/10G SFP+ host downlinks for blade servers, all-flash storage and high-performance compute nodes, paired with four wire-speed 40G QSFP+ fabric uplink ports. Each 40G QSFP+ port can break out to four independent 10G SFP+ channels, expanding total fabric uplink capacity to 16×10G ports. All control plane logic, forwarding rules, QoS, lossless FCoE and security policies are fully centralized and managed on upstream parent Nexus switches (N5000/N5500/N5600/N6000/N7000/N9000). This platform has reached End-of-Sale with all official Cisco hardware support lifecycles expired.
-
Core design advantages: All SFP+ fiber host ports with native FCoE capability, high-capacity 40G breakout uplinks, split ingress/egress large packet buffers, dual airflow options for flexible hot/cold aisle rack deployment
-
Fixed 3:1 oversubscription ratio: 480 Gbps aggregate host bandwidth vs 160 Gbps total fabric uplink bandwidth
-
Carrier-grade redundancy: Hot-swappable dual AC power supplies and dual hot-swappable fan trays to eliminate single power/cooling failure points
2. Part Number Suffix Breakdown & Model Differentiation
Full PN Breakdown
-
N2K: Nexus 2000 Series Fabric Extender product family
-
C2248PQ: 1RU high-density all-fiber FEX chassis
-
48 × auto-sensing 1/10G SFP+ host ports (supports Ethernet and lossless FCoE)
-
P: Dense SFP+ host port bank;Q: Four native 40G QSFP+ fabric uplink ports (breakout to 4×10G per port)
-
No fixed airflow preset: Power supply and fan trays are ordered separately with matching port-side intake / port-side exhaust airflow directions
Key Hardware Comparison vs N2K-C2232PP-10GE
|
Item
|
N2K-C2248PQ
|
N2K-C2232PP-10GE
|
|
Host SFP+ Ports
|
48 × 1/10G
|
32 × 1/10G
|
|
Fabric Uplinks
|
4 × 40G QSFP+ (16×10G breakout)
|
8 × 10G SFP+
|
|
Aggregate Uplink Bandwidth
|
160 Gbps
|
80 Gbps
|
|
Oversubscription Ratio
|
Fixed 3:1
|
Fixed 4:1
|
|
Packet Buffer
|
32 MB ingress / 8 MB egress split buffer
|
Single 8 MB shared buffer
|
|
Deployment Focus
|
High-density all-fiber rack leaf with 40G spine uplinks
|
Medium-density all-fiber rack with 10G-only uplinks
|
Factory Bare Chassis Included Hardware
-
1RU standard 19-inch EIA horizontal rack-mount passive chassis
-
Rear panel fixed port bank:
-
48 × auto-negotiating 1/10G SFP+ host ports for server, virtualization host and all-flash storage connections
-
4 × yellow-labeled 40G QSFP+ fabric uplink ports dedicated to parent switch interconnection
-
Front panel redundant FRU slots: Dual AC power supply bays, dual hot-swappable fan tray slots
-
Complete out-of-band management interfaces: RJ45 RS232 serial console, dual 10/100/1000BASE-T out-of-band management Ethernet, USB Type-A diagnostic flash port
-
Integrated status LED indicators: Global system health, power supply fault, fan fault, per-port link/activity, UID rack locator beacon
-
Standard 19-inch rack mounting rails, front cable management brackets, hardware installation & global safety compliance documentation
Items Not Included (Must Be Ordered Separately)
-
Hot-swappable AC power supplies (minimum two for N+1 redundancy; airflow must match fan trays)
-
Dual hot-swappable fan trays (airflow direction consistent with power supplies to avoid thermal protection shutdown)
-
SFP+ transceivers, Twinax copper DAC, active AOC cables for all 48 host SFP+ ports
-
QSFP+ 40G transceivers, 40G-to-4×10G breakout splitter cables for four fabric uplink ports
-
Optional accessories: Lockable front door, air filter panel, cable management guides, serial console rollover cable
Supported Parent Switch Platforms
Nexus 5000, 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releases (minimum NX-OS 6.0(2)N1(1) for N5K/N6K).
3. Hardware Port & Slot Layout
Rear Panel Fixed Ports
-
48 × 1/10G SFP+ Host Ports
Auto-sensing 1G/10G fiber interfaces compliant with IEEE 802.3ae 10G Ethernet and IEEE DCB lossless standards (802.1Qbb PFC, 802.1Qaz ETS) to carry lossless FCoE storage traffic over multi-mode/single-mode fiber or short-range Twinax DAC cables. All Layer 2, SAN and security policies are enforced centrally on the parent switch, not the FEX itself. Each SFP+ slot supports standard Ethernet transceivers and Fibre Channel SFP+ transceivers for direct SAN storage attachment.
-
4 × 40G QSFP+ Fabric Uplink Ports
Wire-speed 40G Ethernet/FCoE uplinks for high-capacity fabric connectivity to the upstream parent spine/aggregation switch. Each QSFP+ port supports breakout via splitter cables into four independent 10G SFP+ channels, expanding total fabric uplink capacity to 16×10G ports. All four uplinks can be bundled into LACP port-channels for load balancing and full link redundancy.
Front Panel Redundant FRU Slots
-
Two independent hot-swappable AC power supply bays (N+1 redundant deployment supported)
-
Two independent hot-swappable fan tray slots (dual-fan redundancy eliminates single cooling point of failure)
Front Panel LED Status Array
Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 48 host SFP+ and four 40G QSFP+ uplink ports, UID locator beacon for quick rack asset identification.
4. Hardware Performance Specifications
-
Total host port capacity: 48×10G wire-speed downlink ports, total 480 Gbps aggregate host bandwidth
-
Fabric uplink bandwidth: 4×40G full-duplex uplinks, total 160 Gbps aggregate upstream bandwidth
-
Fixed oversubscription ratio: 3:1 (480G host bandwidth / 160G uplink bandwidth)
-
Full-duplex switching capacity: 1280 Gbps; wire-speed forwarding throughput: 952 Mpps (64-byte minimum frame size)
-
Split dynamic packet buffer: 32 MB ingress buffer (network-to-host) + 8 MB egress buffer (host-to-network), optimized for bursty virtualization and FCoE storage workloads
-
VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
-
Port-channel scaling: Supports up to 16 physical host ports per LACP host port-channel / vPC trunk
-
Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk upgrades triggered from a singleinstall allcommand on the parent switch
-
Hardware offload & lossless features (controlled by parent NX-OS):
-
IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE storage transport
-
vPC dual-homing, PVLAN private VLAN, MSTP spanning tree, QoS traffic classification
-
VNTag virtual machine-aware traffic tagging for virtualized server environments
-
Buffer-to-buffer credits for medium-distance Fibre Channel SAN extension via SFP+ FC transceivers
-
Jumbo frame support up to 9216-byte MTU for storage and big-data workloads
Physical & Environmental Parameters
-
Form Factor: 1 RU (43.7 mm height), standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 43.7 mm × 439.4 mm × 449.6 mm (1.72 × 17.3 × 17.7 inches)
-
Bare chassis weight (no PSUs/fans/transceivers): ~6.2 kg (13.7 lbs)
-
Fully loaded maximum weight (dual PSUs + dual fans + full transceivers): ~8.0 kg (17.6 lbs)Cisco Russ...
-
Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
-
Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
-
Operating relative humidity: 5%–95% non-condensing
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated
AC Power Supply FRU Specifications (Sold Separately)
-
Input: Universal 90–264V AC, 50–63Hz
-
Typical full-load power consumption: 230W with all 48 host ports active
-
Hot-swappable OIR replacement, supports N+1 redundant power deployment
5. NX-OS Feature Set (Managed Centrally on Parent Switch)
Layer 2 Ethernet & Converged FCoE Fabric
-
Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
-
802.1Q VLAN tagging, PVLAN private VLAN isolation
-
MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
-
IEEE DCB lossless standards (PFC, ETS) enabling FCoE storage traffic over all SFP+ fiber host ports
-
NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
-
POAP zero-touch automatic provisioning for mass rack FEX deployment
-
Port security, static MAC locking to restrict unauthorized server/storage device attachment
-
Full 1/10G auto-sensing on all SFP+ host ports without transceiver replacement
QoS & Traffic Prioritization
-
Four hardware priority queues per port (all SFP+ host and 40G QSFP+ uplink ports)
-
Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
-
Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, HPC big-data clusters and virtual server farms
-
DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over fiber and Twinax copper DAC interfaces
Monitoring & Automation Tools
-
Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
-
Real-time streaming telemetry: port throughput, latency, frame error counters, SFP/QSFP optical transmit power diagnostics
-
Fault alert notifications via email, syslog and SNMP traps
-
GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
-
Unified bulk firmware upgrade: Single command on parent switch upgrades all attached FEX devices simultaneously
6. Typical Deployment Scenarios for N2K-C2248PQ Bare Chassis
-
Large leaf-spine all-fiber data center leaf rack: 48 SFP+ 10G host ports connect high-density virtualization servers, blade enclosures and all-flash storage arrays; four 40G QSFP+ uplinks deliver high-capacity low-oversubscription connectivity to the spine layer, ideal for high-throughput virtualized workloads
-
Enterprise financial/mainframe unified long-distance SAN-LAN rack: All-fiber design supports LR/ER SFP+ transceivers for cross-building SAN replication, consolidating 10G virtual server links and Fibre Channel storage on a single compact 1RU FEX chassis
-
High-performance computing (HPC) / distributed storage rack aggregation: Large split ingress buffer absorbs massive burst traffic from compute clusters and distributed file systems, avoiding FCoE packet loss under heavy load
-
Legacy Nexus fabric high-density fiber upgrade: Direct replacement for N2K-C2232PP-10GE to boost host port count and uplink bandwidth; backward compatible with existing 10G SFP transceivers and all supported parent switch platforms
-
Medium multi-tenant service provider PoP leaf switch: High-density fiber port design isolates tenant traffic via VLAN/VSAN, with centralized security and QoS policy control on the upstream core parent switch
7. Standard Package Contents of N2K-C2248PQ Bare Chassis SKU
1 × N2K-C2248PQ Nexus 2248PQ 1RU Fabric Extender bare chassis (no power supplies, fan trays or transceivers)
19-inch standard rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation
Separately Mandatory Components (Not Included in This Bare Chassis Bundle)
-
Two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy, airflow matched to fan trays)
-
Two matching airflow hot-swappable fan trays (dual fans recommended for cooling redundancy; airflow must align with power supplies to avoid thermal faults)
-
SFP+ optical transceivers, Twinax DAC copper cables and FET-10G transceivers for all 48 host SFP+ ports
-
QSFP+ 40G transceivers and 4×10G breakout splitter cables for four fabric uplink QSFP+ ports
-
Optional feature software licenses: All fabric, routing and storage features are licensed on the upstream parent Nexus switch; no separate FEX licenses required
-
RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, lockable front door, air filter panel
Short Commercial Catalog Summary for Quotation
Cisco N2K-C2248PQ is an End-of-Sale bare 1RU high-density all-fiber Fabric Extender (FEX) from the Nexus 2000 remote I/O platform, featuring 48 fixed auto-sensing 1/10G SFP+ fiber host ports (native Ethernet/FCoE) plus four 40G QSFP+ fabric uplink ports expandable to 16×10G breakout uplink channels, with a fixed 3:1 oversubscription ratio and split 32MB ingress / 8MB egress dynamic packet buffer optimized for bursty storage and virtualization workloads. This stateless bare chassis does not include power supplies, fan trays or transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It supports dual airflow configurations (port-side intake / port-side exhaust) for flexible hot/cold aisle rack layouts, lossless FCoE transport via IEEE DCB standards, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for large-scale all-fiber leaf-spine data center leaf aggregation and enterprise financial unified SAN/LAN deployments requiring high-density 10G host ports and 40G spine uplinks, limited by fiber-only host port design, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
|
|
|
| Click:33 Entry Time:2026-07-15 【Print】 【Close】 |
|
|
|
|