Cisco N2K-C2248TP Full Product Description
1. Short Overview
N2K-C2248TPis a 1RU high-density Gigabit Fabric Extender (FEX) from the Cisco Nexus 2000 Series, a stateless remote I/O device that expands port capacity for upstream parent Nexus switches (N5000/N5500/N5600/N6000/N7000/N9000). It provides 48 auto-sensing 10/100/1000BASE-T RJ45 copper host downlinks for rack servers, virtualization hosts and entry storage, paired with four wire-speed 10G SFP+ fabric uplink ports to connect to the parent switch. All control plane logic, forwarding policies, QoS, SAN convergence and security rules are fully centralized on the parent NX-OS switch; the FEX only performs local packet buffering and traffic tunneling over fabric links. The entire Nexus 2000 2248TP platform has reached End-of-Sale, and all standard hardware support lifecycles have expired.
-
Dual airflow support: Port-side exhaust (front-to-back) or port-side intake (back-to-front) power/fan FRUs to match any hot/cold aisle rack layout; airflow modules must be consistent to avoid thermal faultsManualsLib
-
Flexible oversubscription: Ratios range from 1.2:1 (4 active uplinks) up to 4.8:1 (single uplink)
-
Redundant hardware design: Hot-swappable dual AC power supplies and dual fan trays for carrier-grade non-stop operation
2. Part Number Suffix Breakdown
-
N2K: Nexus 2000 Series Fabric Extender product family
-
C2248TP: 1RU high-density FEX chassis model
-
48 × 10/100/1000BASE-T copper host ports
-
T = Copper 1GBASE-T interfaces;P = Four SFP+ 10G fabric uplink ports
-
No fixed airflow preset: Power supply and fan trays are ordered separately to define chassis cooling direction
Factory Bare Chassis Included Hardware
-
1RU standard 19-inch EIA horizontal rack-mount passive chassis
-
Rear panel fixed port bank:
-
48 × auto-negotiating 10/100/1000BASE-T RJ45 host ports for server/VM host connections
-
4 × yellow-labeled SFP+ 10G fabric uplink ports dedicated to parent switch interconnection
-
Front panel redundant FRU slots: Dual AC power supply bays, dual hot-swappable fan tray slots
-
Integrated status LED indicators: Global system health, power supply fault, fan fault, per-port link/activity, UID rack locator beacon
-
Standard 19-inch rack mounting rails, front cable management brackets, hardware installation & global safety compliance documentation
Items Not Included (Must Be Ordered Separately)
-
Hot-swappable AC power supplies (single PSU for basic operation, dual PSUs for N+1 power redundancy; airflow matched to fan trays)
-
Hot-swappable fan trays (single fan for basic operation, dual fans for redundant cooling; airflow must align with power supplies)
-
SFP+ transceivers, Twinax copper DAC cables and FET-10G fabric extenders for four 10G fabric uplink ports (SR/LR optical or short-range passive copper)ManualsLib
-
Optional accessories: Lockable front door, air filter panel, cable management guides, serial console rollover cable
Supported Parent Switch Platforms
All Nexus 5000, 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releases.
Key Differentiator vs N2K-C2224TP
|
Item
|
N2K-C2248TP
|
N2K-C2224TP
|
|
Host Ports
|
48 × 1GBASE-T
|
24 × 1GBASE-T
|
|
Fabric Uplinks
|
4 × 10G SFP+
|
2 × 10G SFP+
|
|
Max Aggregate Upstream Bandwidth
|
40 Gbps
|
20 Gbps
|
|
Max Oversubscription
|
4.8:1
|
1.2:1
|
|
Packet Buffer
|
8 MB shared buffer
|
8 MB shared buffer
|
3. Hardware Port & Slot Layout
Rear Panel Fixed Ports
-
48 × 10/100/1000BASE-T RJ45 Host Ports
Auto-sensing 1G copper interfaces compliant with IEEE 802.3ab Gigabit Ethernet. Supports lossless FCoE transport over CAT5e/CAT6 cabling via IEEE DCB PFC/ETS standards; all Layer 2, SAN and security policies are enforced centrally on the parent switch, not the FEX itselfCisco Russ....
-
4 × SFP+ 10G Fabric Uplink Ports (Yellow Labeled)
Wire-speed 10G Ethernet uplinks for fabric connectivity to the upstream parent switch. Supports SFP+ optical transceivers (SR, LR, ER), passive Twinax DAC cables and dedicated FET-10G fabric extender transceivers. Multiple uplinks can be bundled into LACP port-channels for load balancing and link failure redundancyManualsLib.
Front Panel Redundant FRU Slots
-
Two independent hot-swappable AC power supply bays (N+1 redundant deployment supported)
-
Two independent hot-swappable fan tray slots (dual-fan redundancy eliminates single cooling point of failure)
Front Panel LED Status Array
Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 48 RJ45 and four SFP+ ports, UID locator beacon for rack asset identification.
4. Hardware Performance Specifications
-
Total host port capacity: 48×1G wire-speed downlink ports, total 48 Gbps aggregate host bandwidth
-
Fabric uplink bandwidth: 4×10G full-duplex uplinks, total 40 Gbps aggregate upstream bandwidth
-
Supported oversubscription ratios:
-
4 active uplinks: 48:40 = 1.2:1 mild oversubscription
-
1 active uplink: 48:10 = 4.8:1 maximum oversubscription
-
Switching throughput: 176 Gbps full-duplex switching capacity, 131 Mpps wire-speed forwarding rate
-
Shared dynamic packet buffer: 8 MB, optimized for bursty server LAN and FCoE storage trafficCisco
-
VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
-
Port-channel scaling: Each FEX supports up to 16 physical ports per vPC/host port-channel
-
Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk upgrades triggered from the parent switch single command
-
Hardware offload & lossless features (controlled by parent NX-OS):
-
IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE storage transport
-
vPC dual-homing, PVLAN private VLAN, MSTP spanning tree, QoS traffic classification
-
VNTag virtual machine-aware traffic tagging for virtualized server environments
Physical & Environmental Parameters
-
Form Factor: 1 RU (4.37 cm height), standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 43.7 mm × 439.4 mm × 449.6 mm (1.72 × 17.3 × 17.7 inches)
-
Bare chassis weight (no PSUs/fans/transceivers): ~5.4 kg (11.9 lbs)
-
Fully loaded maximum weight (dual PSUs + dual fans + transceivers): ~7.2 kg (15.9 lbs)
-
Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
-
Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
-
Operating relative humidity: 5%–95% non-condensing
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated
AC Power Supply FRU Specifications (Sold Separately)
-
Input: Universal 90–264V AC, 50–63Hz
-
Typical full-load power consumption: 165W with all 48 host ports activeCisco
-
Hot-swappable OIR replacement, supports N+1 redundant power deployment
5. NX-OS Feature Set (Managed Centrally on Parent Switch)
Layer 2 Ethernet & Converged FCoE Fabric
-
Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
-
802.1Q VLAN tagging, PVLAN private VLAN isolation
-
MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
-
IEEE DCB lossless standards (PFC, ETS) enabling FCoE storage traffic over 1G copper host ports
-
NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
-
POAP zero-touch automatic provisioning for mass rack FEX deployment
-
Port security, static MAC locking to restrict unauthorized server/storage device attachment
QoS & Traffic Prioritization
-
Four hardware priority queues per port (1G copper and 10G fabric uplinks)
-
Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
-
Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, virtual server workloads and tape archives
-
DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over copper host ports
Monitoring & Automation Tools
-
Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
-
Real-time streaming telemetry: port throughput, latency, frame error counters, SFP optical transmit power diagnostics
-
Fault alert notifications via email, syslog and SNMP traps
-
GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
-
Unified bulk firmware upgrade: Singleinstall allcommand on parent switch upgrades all attached FEX devices simultaneously
6. Typical Deployment Scenarios for N2K-C2248TP FEX
-
High-density virtualized data center top-of-rack expansion: Cost-effective 48-port Gigabit copper extension for dense server racks, consuming only four high-value 10G uplink ports on the parent ToR switch; supports mild oversubscription for general virtualization workloads
-
Medium enterprise unified LAN/FCoE storage rack: Supports lossless FCoE over low-cost CAT5e/CAT6 copper cabling for medium-scale all-flash storage arrays, extending the parent switch’s SAN convergence capability without expensive unified port line cards
-
Virtualization production farm rack aggregation: Mass low-density VM host connectivity with centralized vPC, QoS and security policy management on the parent switch, ensuring consistent policy enforcement across hundreds of rack servers
-
Legacy data center migration cost optimization: Reuses existing Gigabit copper cabling infrastructure while maintaining a single unified fabric management plane; gradual migration path to 10G server ports via parent switch hardware refresh
-
Multi-tenant medium PoP edge access: High-density rack-level multi-tenant port expansion with complete VLAN isolation controlled on the upstream core parent switch
7. Standard Package Contents of N2K-C2248TP Bare Chassis SKU
1 × N2K-C2248TP Nexus 2248TP 1RU Fabric Extender bare chassis (no power supplies, fan trays or SFP+ transceivers)
19-inch standard rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation
Separately Mandatory Components (Not Included in This Bare Chassis Bundle)
-
One or two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy, airflow matched to fan trays)
-
One or two matching hot-swappable fan trays (dual fans recommended for cooling redundancy; airflow must align with power supplies to avoid thermal faults)
-
SFP+ optical transceivers, Twinax DAC copper cables and FET-10G transceivers for four 10G fabric uplink ports
-
Optional feature software licenses: All fabric, routing and storage features are licensed on the parent upstream Nexus switch, no separate FEX licenses required
-
RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, lockable front door, air filter panel
Short Commercial Catalog Summary for Quotation
Cisco N2K-C2248TP is an End-of-Sale bare 1RU high-density Gigabit Fabric Extender (FEX) from the Nexus 2000 remote I/O platform, featuring 48 fixed auto-sensing 10/100/1000BASE-T RJ45 copper host ports plus four SFP+ 10G fabric uplink ports for attachment to upstream Nexus parent switches. This stateless bare chassis does not include power supplies, fan trays or SFP+ transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It supports dual airflow configurations (port-side intake / port-side exhaust) for flexible hot/cold aisle rack layouts, variable oversubscription ratios from 1.2:1 to 4.8:1, lossless FCoE transport via IEEE DCB, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for high-density Gigabit server rack expansion and medium enterprise unified LAN/SAN small data center deployments, limited by pure 1G copper host port design, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
|
|
|
| Click:28 Entry Time:2026-07-15 【Print】 【Close】 |
|
|
|
|