|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71511265916 |
ProductName: |
N2K-C2224TP |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco N2K-C2224TP Full Product Description
1. Short Overview
N2K-C2224TPis a compact 1RU Gigabit Fabric Extender (FEX) from the Cisco Nexus 2000 Series, a stateless remote I/O device that extends port density for upstream parent Nexus switches (N5000/N5500/N5600/N6000/N7000/N9000). It provides 24 auto-sensing 10/100/1000BASE-T RJ45 host downlinks for rack servers and virtualization hosts, paired with two wire-speed 10G SFP+ fabric uplink ports to connect to the parent switch. All control plane logic, forwarding rules, QoS, SAN convergence and security policies are fully centralized on the parent NX-OS switch; the FEX performs only local data plane packet buffering and traffic tunneling over fabric links. The Nexus 2224TP platform has reached End-of-Sale, and all official Cisco hardware support lifecycles have expiredCisco.
-
Core architecture: Stateless remote port extender, zero independent control plane; unified single-pane management via parent switch CLI/DCNM
-
Fixed airflow design: Front-to-back cooling, compatible with standard hot/cold aisle data center rack layouts
-
Built-in redundancy support: Hot-swappable dual AC power supplies and dual fan trays for non-stop production operation
-
Fixed oversubscription ratio: 24G total host bandwidth vs 20G aggregate fabric uplink bandwidth, maximum 1.2:1 oversubscription with both uplinks active
2. Part Number Suffix Breakdown
-
N2K: Nexus 2000 Series Fabric Extender product family
-
C2224TP: 1RU compact FEX chassis model
-
24 × 10/100/1000BASE-T copper host ports
-
T = Copper 1GBASE-T interfaces;P = Two SFP+ 10G fabric uplink ports
-
Fixed front-to-back airflow, no optional airflow variants
Factory Bare Chassis Included Hardware
-
1RU standard 19-inch EIA horizontal rack-mount passive chassis
-
Rear panel fixed port bank:
-
24 × auto-negotiating 10/100/1000BASE-T RJ45 host ports for server/VM host connections
-
2 × SFP+ 10G fabric uplink ports dedicated to parent switch interconnection
-
Front panel redundant FRU slots: Dual AC power supply bays, dual hot-swappable fan tray slots
-
Integrated status LED indicators: Global system health, power supply fault, fan fault, per-port link/activity, UID rack locator beacon
-
Standard 19-inch rack mounting rails, front cable management brackets, hardware installation & global safety compliance documentation
Items Not Included (Must Be Ordered Separately)
-
Hot-swappable AC power supplies (single PSU for basic operation, dual PSUs for N+1 power redundancy)
-
Hot-swappable fan trays (single fan for basic operation, dual fans for redundant cooling)
-
SFP+ transceivers and Twinax copper DAC cables for two 10G fabric uplink ports (SR/LR optical or short-range passive copper)
-
Optional accessories: Lockable front door, air filter panel, cable management guides
Supported Parent Switch Platforms
All Nexus 5000, 5500, 5600, 6000, 7000/7700, and 9000 series data center switches running compatible NX-OS firmware releasesCisco.
3. Hardware Port & Slot Layout
Rear Panel Fixed Ports
-
24 × 10/100/1000BASE-T RJ45 Host Ports
Auto-sensing 1G copper interfaces compliant with IEEE 802.3ab Gigabit Ethernet. Supports lossless FCoE transport over CAT5e/CAT6 cabling via IEEE DCB PFC/ETS standards; all Layer 2, SAN and security policies are enforced centrally on the parent switch, not the FEX itselfCisco Russ....
-
2 × SFP+ 10G Fabric Uplink Ports
Wire-speed 10G Ethernet uplinks for fabric connectivity to the upstream parent switch. Supports SFP+ optical transceivers (SR, LR, ER) and passive Twinax DAC cables. The two uplinks can be bundled into LACP port-channels for load balancing and link failure redundancy.
Front Panel Redundant FRU Slots
-
Two independent hot-swappable AC power supply bays (N+1 redundant deployment supported)
-
Two independent hot-swappable fan tray slots (dual-fan redundancy eliminates single cooling point of failure)
Front Panel LED Status Array
Global chassis health LED, individual power supply fault LEDs, fan tray fault indicators, per-port link/activity LEDs for all 24 RJ45 and two SFP+ ports, UID locator beacon for rack asset identification.
4. Hardware Performance Specifications
-
Total host port capacity: 24×1G wire-speed downlink ports, total 24 Gbps aggregate host bandwidth
-
Fabric uplink bandwidth: 2×10G full-duplex uplinks, total 20 Gbps aggregate upstream bandwidth
-
Maximum oversubscription ratio: 1.2:1 when both 10G uplinks are active
-
Switching throughput: 88 Gbps full-duplex switching capacity, 65 Mpps wire-speed forwarding rateCisco
-
Dynamic shared packet buffer: Optimized for bursty virtualized server LAN and FCoE storage traffic
-
VLAN support: Up to 4094 standard IEEE 802.1Q VLANs, configured and managed exclusively on the parent switch
-
Port-channel scaling: Supports up to 8 physical host ports per LACP host port-channel / vPC trunk
-
Zero-touch provisioning: Automatic firmware synchronization, configuration download and bulk upgrades triggered from the parent switch single command
-
Hardware offload & lossless features (controlled by parent NX-OS):
-
IEEE DCB standards (PFC Priority Flow Control, ETS Enhanced Transmission Selection) for lossless FCoE storage transport
-
vPC dual-homing, PVLAN private VLAN, MSTP spanning tree, QoS traffic classification
-
VNTag virtual machine-aware traffic tagging for virtualized server environments
Physical & Environmental Parameters
-
Form Factor: 1 RU (4.37 cm height), standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 43.7 mm × 439.4 mm × 449.6 mm (1.72 × 17.3 × 17.7 inches)
-
Bare chassis weight (no PSUs/fans/transceivers): ~4.8 kg (10.6 lbs)
-
Fully loaded maximum weight (dual PSUs + dual fans + transceivers): ~6.5 kg (14.3 lbs)
-
Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 3,000 meters
-
Storage temperature range: -40°C ~ 70°C (-40°F ~ 158°F)
-
Operating relative humidity: 5%–95% non-condensing
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic compliance, RoHS 6 validated
AC Power Supply FRU Specifications (Sold Separately)
-
Input: Universal 90–264V AC, 50–60Hz
-
Typical full-load power consumption: 130W with all 24 host ports active
-
Hot-swappable OIR replacement, supports N+1 redundant power deployment
5. NX-OS Feature Set (Managed Centrally on Parent Switch)
Layer 2 Ethernet & Converged FCoE Fabric
-
Single centralized management plane; all FEX ports appear as logical HIF (Host Interface) interfaces on the parent NX-OS switch
-
802.1Q VLAN tagging, PVLAN private VLAN isolation
-
MSTP multi-instance spanning tree, vPC dual-active peer-link redundancy for server high availability
-
IEEE DCB lossless standards (PFC, ETS) enabling FCoE storage traffic over 1G copper host ports
-
NPV/NPIV FCoE edge virtualization for unified LAN-SAN data center convergence
-
POAP zero-touch automatic provisioning for mass rack FEX deployment
-
Port security, static MAC locking to restrict unauthorized server/storage device attachment
QoS & Traffic Prioritization
-
Four hardware priority queues per port (1G copper and 10G fabric uplinks)
-
Ingress policing, egress bandwidth shaping to throttle low-priority tape backup and replication traffic
-
Pre-built QoS templates optimized for OLTP databases, all-flash NVMe storage, virtual server workloads and tape archives
-
DCBX auto-negotiation for lossless FCoE LAN/SAN traffic over copper host ports
Monitoring & Automation Tools
-
Cisco DCNM centralized converged fabric monitoring, provisioning and REST API automation
-
Real-time streaming telemetry: port throughput, latency, frame error counters, SFP optical transmit power diagnostics
-
Fault alert notifications via email, syslog and SNMP traps
-
GOLD Generic Online Diagnostics for continuous FEX hardware health validation without production traffic interruption
-
Unified bulk firmware upgrade: Singleinstall allcommand on parent switch upgrades all attached FEX devices simultaneously
6. Typical Deployment Scenarios for N2K-C2224TP FEX
-
Small/medium rack compact server expansion: Cost-effective 24-port Gigabit copper extension for racks with limited server density, consuming only two high-value 10G ports on the parent ToR switch
-
Entry-level unified LAN/FCoE storage rack: Supports lossless FCoE over low-cost CAT5e/CAT6 copper cabling for small all-flash storage arrays, extending the parent switch’s SAN convergence capability without expensive unified port line cards
-
Virtualization test/dev farm rack aggregation: Low-density VM host connectivity with centralized vPC, QoS and security policy management on the parent switch, ensuring consistent policy enforcement across all rack servers
-
Legacy data center migration cost optimization: Reuses existing Gigabit copper cabling infrastructure while maintaining a single unified fabric management plane; gradual migration path to 10G server ports via parent switch hardware refresh
-
Small multi-tenant branch PoP edge access: Low-cost rack-level multi-tenant port expansion with complete VLAN isolation controlled on the upstream core parent switch
7. Standard Package Contents of N2K-C2224TP Bare Chassis SKU
1 × N2K-C2224TP Nexus 2224TP 1RU Fabric Extender bare chassis (no power supplies, fan trays or SFP+ transceivers)
19-inch standard rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation
Separately Mandatory Components (Not Included in This Bare Chassis Bundle)
-
One or two hot-swappable AC power supplies (dual PSUs recommended for N+1 power redundancy)
-
One or two matching hot-swappable fan trays (dual fans recommended for cooling redundancy)
-
SFP+ optical transceivers and Twinax DAC copper cables for two 10G fabric uplink ports
-
Optional accessories: Lockable front door, air filter panel, serial console cable for parent switch management
Short Commercial Catalog Summary for Quotation
Cisco N2K-C2224TP is an End-of-Sale bare compact 1RU Gigabit Fabric Extender (FEX) from the Nexus 2000 remote I/O platform, featuring 24 fixed auto-sensing 10/100/1000BASE-T RJ45 copper host ports plus two SFP+ 10G fabric uplink ports for attachment to upstream Nexus parent switches. This stateless bare chassis does not include power supplies, fan trays or SFP+ transceivers (all FRUs purchased separately); all switching, security, QoS and SAN convergence functions are configured and managed centrally on the parent NX-OS switch. It adopts front-to-back airflow for standard hot/cold aisle rack layouts, supports a fixed 1.2:1 maximum oversubscription ratio, lossless FCoE transport via IEEE DCB, zero-touch provisioning and synchronized bulk firmware upgrades. Optimized for space-saving low-density Gigabit server rack expansion and entry-level unified LAN/SAN small data center deployments, limited by pure 1G copper host port design, only two fabric uplinks, stateless remote I/O architecture and expired official hardware support lifecycle. Compliant with global safety, EMI, NEBS Level 3 and RoHS 6 industrial standards.
|
|
|
| Click:11 Entry Time:2026-07-15 【Print】 【Close】 |
|
|
|
|