Cisco N77-C7718 (Nexus 7718) Full Product Description
1. Short Overview
Cisco N77-C7718 is a massive 26RU 18-slot flagship modular converged LAN/FCoE data center core bare chassis from the Cisco Nexus 7700 next-gen 100G unified fabric platform, released June 25, 2013, End-of-Sale Oct 12, 2023, Final Hardware Support Expires Oct 31, 2028Cisco. It adopts parallel crossbar Fabric-2 architecture with up to six rear hot-swappable fabric modules, two native half-slot redundant Supervisor-2E/3E slots + 16 full universal I/O line card slots, front-to-back cold aisle airflow, three independent hot-swappable fan trays, up to sixteen 3kW / 3.5kW AC/DC/HVDC power supplies. Full-chassis non-blocking throughput reaches83 Tbps full-duplexwith six Fabric-2 modules fully loaded, maximum port density: 768×10G, 384×40G, 192×100G Ethernet/FCoE portsCisco. It runs NX-OS 8.x/9.x, natively supports lossless FCoE SAN-LAN convergence, VDC multi-tenant virtual switching, OTV cross-DC overlay, LISP workload mobility, full MPLS/EVPN carrier transport, complete OIR hot-swap FRU maintenance. Targeted for hyperscale enterprise data center core, multi-pod campus aggregation, large service provider multi-tenant PoP border, unified end-to-end SAN-LAN fabric and cross-region disaster recovery workloads.
2. Official Lifecycle & Chassis Definition
-
Bare chassis PN:N77-C7718(empty frame without supervisors, fabric modules, power supplies, I/O line cards, transceivers; bundled SKUs like N77-C7718-B26S2E ship pre-populated with core hardware)
-
EOL Timeline: EOS Oct 12, 2023; Final HW Support Oct 31, 2028Cisco
Core Hardware Differentiators vs N77-C7702 / N77-C7706 / N77-C7710 smaller chassis
-
Industry-leading I/O expansion scale: 16 universal full I/O line card slots (N77-C7702 only 1, N77-C7706 only 4, N77-C7710 only 8), peak 192×100G ports vs 12×100G on 7702 / 48×100G on 7706 / 96×100G on 7710
-
High-capacity external rear fabric subsystem: Six dedicated N77-C7718-FAB-2 fabric module slots (active-active parallel load-sharing, scalable total fabric bandwidth up to 83 Tbps); small 7702 uses embedded distributed fabric ASICs on I/O cards with no separate fabric modules and only 2.4 Tbps total capacity; 7706 max 21 Tbps, 7710 max 42 Tbps
-
Dual native half-slot supervisor slots (built-in full control-plane redundancy, supports dual Sup2/Sup2E/Sup3E out of box; N77-C7702 only single supervisor slot with no second native bay)
-
Three independent hot-swappable fan trays (layered redundant cooling; N77-C7702 single integrated fan tray, 7706 triple fans but smaller chassis cooling volume)
-
Up to sixteen hot-swappable power supply bays (massive redundant power pool; all smaller 7700 chassis only max 4 PSUs)
-
Standard front-to-back cold aisle airflow (industry mainstream design, compatible with all standard data center rack layouts; 7702 uses side-to-back airflow with limited rack compatibility)
-
Unified Nexus 7700 Gen3 module compatibility: All F2/F3/F4/M3 10/40/100G I/O line cards, Sup2/Sup2E/Sup3E supervisors fully interchangeable across all Nexus 7700 chassis to unify spare inventory cost
-
Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe low-latency tunneling, full FICON zSystems storage integration without external gateway appliances
Core High-Availability Architecture
All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live maintenance without data plane outage. Up to sixteen identical 3000W / 3500W Platinum AC/DC/HVDC power supplies deliver multi-N+1 redundant power operation; three independent multi-fan trays provide layered chassis cooling, single fan tray failure triggers SNMP alert without immediate traffic shutdown. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context partitions multi-tenant LAN workloads to prevent broadcast storm leakage across logical domains. NPV/NPIV edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Dual supervisor modules (Slot49 active, Slot50 standby) maintain full stateful synchronization, zero-I/O-loss automatic failover and non-disruptive ISSU firmware upgrades. Six independent crossbar fabric modules operate in parallel load-sharing mode; removing any single fabric module does not degrade overall chassis throughput capacity.
Target deployment scenarios: Hyperscale virtualized multi-pod data center core SAN-LAN aggregation, multi-building enterprise campus distributed storage root, large regional mission-critical cross-site disaster recovery SAN gateway, large MPLS service provider multi-tenant PoP edge border switch, unified campus-wide SAN-LAN fabrics interoperable with N77-C7702 compact pod core switches, N77-C7706 mid-size core directors, N77-C7710 large core directors and MDS 9000 SAN directors.
Model Suffix Breakdown
-
N77: Nexus 7700 next-gen 100G modular data center switch platform prefix
-
C7718: Bare empty 18-slot front chassis (16 I/O line card slots + 2 half-slot supervisor slots) + rear six fabric module slots
-
Bare chassis N77-C7718 has no K9 suffix; pre-bundled hardware SKUs with supervisors/power supplies carry -2K9 / -B26S2E suffix
-
Airflow fixed front-to-back cold intake (no separate E hot-aisle exhaust chassis variant)
3. Chassis Slot & Hardware Layout Definition
Front Panel 18 Horizontal Slots (26RU 19-inch rack)
-
Slots 1–16: Sixteen universal hot-swappable I/O line/service module slots (F2/F3/F4/M3 10/40/100G Ethernet/FCoE switching cards, DS-X9334 FCIP multi-protocol extension modules, SSM encryption/asynchronous replication service modules)
-
N77-F348XP-23: 48×10G SFP+ high-density F3 series line card
-
N77-F324FQ-25: 24×40G QSFP+ F3 series line card
-
N77-F312CK-26: 12×100G QSFP28 F3 maximum-density line card (max 192×100G ports full chassis)
-
N77-M348XP-23L: M3 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
-
N77-F430CQ-36: F4 next-gen 30×100G high-density line card
-
Slots 49,50: Dedicated half-slot Supervisor-2E / Supervisor-3E fabric control module slots (dual redundant native to chassis, active/standby deployment standard)
Rear Panel Redundant Subsystems
-
Up to six independent hot-swappable N77-C7718-FAB-2 crossbar fabric switching modules (parallel load-sharing for scalable 83 Tbps total throughput)
-
Sixteen independent hot-swappable power supply bays supporting AC 3kW / 3.5kW HV HVDC / DC 3kW power modules (mass multi-N+1 redundant power protection)ManualsLib
-
Three independent hot-swappable multi-fan variable-speed fan tray bays (N77-C7718-FAN Gen1 / N77-C7718-FAN-2 Gen2 high-airflow fan trays; mixing Gen1/Gen2 triggers critical thermal alarm after 6 hours)
Out-of-Band Management Interfaces (each Supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export dedicated interface)
-
External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
-
Physical reset button for factory default configuration recovery
Front Global Diagnostic LED Bank
Chassis system health status, power supply group fault indicators, three rear fan tray fault indicators, six fabric module status, dual supervisor module health, sixteen I/O line card port link activity, hardware fault alarm, UID locator beacon LED
Airflow Specification
Fixed front-to-back airflow: Cold air intake from front panel side, hot air exhausted from rear power/fabric compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N77-C7718)
Supported Transceivers & Pluggable Modules
-
Ethernet/FCoE optical transceivers (sold separately for all line card ports):
-
SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
-
QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
-
QSFP28: 100G-SR4/LR4 for 100G high-density uplink/host ports
-
Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
-
Supervisor module compatibility: Supervisor-2E (N77-SUP2E), Supervisor-3E (N77-SUP3E upgraded larger memory, enhanced FCoE telemetry NPU, Secure Boot)Cisco
-
Fabric module compatibility: N77-C7718-FAB-2 Generation2 crossbar fabric modules (six required for full 83 Tbps chassis bandwidth)
-
Power supply compatibility: 3000W AC PEM modules (N77-AC-3KW-WS), 3000W DC PEM telecom modules (N77-DC-3KW-WS), 3.5kW HV HVDC power supplies (N77-HV-3.5KW-WS), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Performance Specifications
Core Switching & Routing Performance
-
Full-chassis parallel crossbar fabric maximum aggregate bandwidth: 83 Tbps full-duplex system-wide throughput with six Fabric-2 modules fully loadedCisco
-
Wire-speed frame forwarding rate: Up to 83000 Mpps Ethernet frame switching at full 100G line rate
-
Low-latency distributed shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
-
MAC address table capacity: 128,000 MAC entries
-
IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
-
Maximum isolated VDC virtual switch contexts: 8 independent logical switch partitions + 1 admin VDC
-
Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
-
Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
-
NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload suite: FC-NVMe ultra-low-latency frame tunneling, FCoE lossless PFC/DCBX/VNTag processing, vPC peer synchronization, OTV cross-DC encapsulation, LISP endpoint mapping, FCIP tunnel compression/tape pipelining, DMM non-disruptive data migration, IOA storage I/O acceleration, onboard streaming telemetry export
Power & Cooling System
-
Power supply bays: 16 hot-swappable redundant slots, each 3000W AC PSU fully powers complete chassis independently (mass multi-N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal alternating current, 80 Plus Platinum high efficiency
-
Fan trays: Three independent hot-swappable multi-fan variable-speed assemblies; minimum two full fan trays functional to avoid thermal shutdown, single fan tray failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C short-term emergency operation
-
Typical full-load power draw: 720W fully populated with sixteen 48-port 100G line cards + dual supervisors + six fabric modules + sixteen AC power supplies under maximum traffic load
-
MTBF: 180,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 26 RU standard 19-inch horizontal rack mountCisco
-
External dimensions (H × W × D): 114.9 cm × 43.9 cm × 88.9 cm (26 rack units, 17.3 × 35.0 inch depth); extended depth 101.3cm with cable management guide installed
-
Bare chassis weight (N77-C7710 empty frame only, no fans/PSUs/supervisors/fabric/line cards): 135 kg (298 lbs)
-
Fully loaded maximum weight (sixteen AC PSUs + three fan trays + six fabric modules + dual supervisors + sixteen 48-port 100G line cards): ~192 kg (423 lbs)
-
Operating ambient temperature range: 0°C to 40°C (32°F to 104°F); certified altitude up to 4000mCisco
-
Storage temperature range: -40°C to 70°C (-40°F to 158°F)
-
Relative humidity: 8%–80% non-condensing operating; 5%–90% non-condensing storageCisco
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic Zone 4, RoHS, FIPS 140-2 Level 2 validated
Supervisor-2E (N77-SUP2E) Built-in Hardware Specs
-
Dual-core x86 enterprise CPU, 16GB DRAM, 16GB internal compact flash storage
-
Dual 1G out-of-band management Ethernet ports, RS232 serial + mini USB local dual console ports
-
External USB flash port for NX-OS image/config backup and offline diagnostics
-
Dedicated onboard NPU for real-time streaming LAN/SAN performance telemetry export
5. Full NX-OS Feature Set Supported
Layer 2 Ethernet & Converged FCoE Storage Fabric Services
-
VDC Virtual Device Context: Logical multi-tenant isolation to separate production/test/backup LAN/SAN workloads on single physical chassis (8 independent VDCs)
-
4094 VLANs per VDC, PVLAN private VLAN anti-spoofing isolation
-
Complete lossless FCoE protocol stack: VSAN virtual storage fabrics, hard WWN zoning, Auto-Zone automatic fabric provisioning, FC-NVMe low-latency forwarding
-
MSTP multi-instance spanning tree for Layer 2 loop prevention, vPC dual-active peer-link redundancy, SPAN/RSPAN remote traffic mirroring for multi-session performance troubleshooting
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
-
Slow drain detection and buffer credit congestion isolation hardware feature to eliminate lossless storage traffic packet loss
-
POAP Power On Auto Provisioning zero-touch automatic switch deployment for mass rack rollouts
Multilayer Routing & Cross-Data Center Interconnect Features
-
Dynamic IPv4/IPv6 routing protocols: OSPF, EIGRP, BGP
-
VRF virtual routing and forwarding multi-tenant Layer 3 isolation
-
Licensed IVR Inter-VSAN Routing feature for secure cross-storage-fabric data forwarding
-
OTV Overlay Transport Virtualization: Cross-DC Layer 2 workload mobility for geographically separated disaster recovery data centers
-
LISP Locator/ID Separation Protocol: Multi-pod workload mobility and distributed data center interconnection
-
Full carrier-grade MPLS suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
-
FCIP tunnel hardware acceleration: Lossless compression, write acceleration, tape pipelining for long-distance off-site tape backup replication
-
iSCSI multi-protocol gateway processing via M3 service line cards for IP-attached server consolidation
Advanced QoS & Traffic Prioritization
-
Four hardware priority queues per Ethernet/FCoE port for tiered classification of storage I/O, virtual machine east-west traffic, management and backup streams
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication traffic
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization over 10/40/100G ports
Enterprise & Service Provider Security Suite
-
Port security: Static MAC locking to block unauthorized physical server/storage device attachment
-
RBAC granular multi-tier administrative access control, integrated with Cisco ISE identity services engine
-
SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
-
Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 Level 2 compliance for government and financial regulated enterprise environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN/LAN Management Tools
-
Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
-
Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
6. High Availability Capabilities (Core Differentiators vs N77-C7706 / N77-C7710 Mid-Size Chassis)
-
Dual redundant Supervisor-2 / Supervisor-2E fabric control modules native to chassis with stateful failover and ISSU non-disruptive firmware upgrades (shared HA architecture with all Nexus 7700 chassis)
-
Sixteen universal I/O line card expansion slots vs four on N77-C7706 / eight on N77-C7710, maximum port density 192×100G vs 48×100G on 7706 / 96×100G on 7710
-
Six independent active-active load-sharing crossbar fabric modules delivering 83 Tbps full non-blocking throughput (N77-C7706 max 21 Tbps total bandwidth; N77-C7710 max 42 Tbps total bandwidth)
-
Up to sixteen hot-swappable high-efficiency 3kW AC redundant power supplies (mass multi-N+1 power redundancy; N77-C7706 only three PSUs; N77-C7710 only four PSUs with limited redundancy)
-
Three independent layered hot-swappable fan trays with multi-fan fault tolerance (shared cooling architecture with N77-C7706, larger chassis cooling volume for full sixteen I/O card load)
-
Full OIR hot-swap maintenance support for all critical FRUs: fabric modules, fan trays, power supplies, supervisors, line cards without chassis power cycle
-
Front-to-back airflow design compatible with mainstream enterprise cold aisle rack deployments (shared airflow standard with all large Nexus 7700 chassis)
-
Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation feature set fully consistent across Nexus 7700 family
-
26RU rack footprint for hyperscale core aggregation deployments (N77-C7706 is 9RU, N77-C7710 is 14RU for medium core deployments)
-
Limitation: Fixed sixteen I/O slot ceiling with no expansion beyond built-in line card bays, legacy maximum 100G Ethernet hardware generation, end-of-sale since Oct 12, 2023, hardware support expiring Oct 31, 2028.
7. Typical Deployment Scenarios
-
Hyperscale Virtualized Multi-Pod Data Center Core SAN-LAN Director
26RU modular rack form factor deployed as campus central SAN/LAN core aggregation director; sixteen 48-port 100G F3/F4 line cards populate all I/O slots for 192 total 100G ports connecting distributed building N77-C7710 medium core switches, massive all-flash NVMe FCoE storage arrays and ultra-high-density blade server racks, dual redundant supervisors + six active fabric modules deliver zero-failover fabric reliability, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN logical fabrics.
-
Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
Multiple N77-C7718 large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, triple redundant fan trays + sixteen redundant power supplies ensure stable cooling/power during hardware maintenance, built-in FCIP hardware offload provisions asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Large Regional Mission-Critical Headquarters Converged Storage/LAN Switch
Financial, healthcare and government headquarters deployments require complete multi-N+1 power + three layered fan trays + dual supervisors + six-fabric-module full hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant logical switch partitioning supports mixed enterprise and agency workloads on a single massive chassis.
-
Large MPLS Service Provider Multi-Tenant Metro PoP Edge Gateway
Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N77-C7718 ideal for large metro PoP edge deployments, terminating massive-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and L4-L7 service M3 line card upgrades.
-
Legacy Large-Scale SAN-LAN Fabric Consolidation Migration Director
Drop-in performance upgrade for aging Nexus 7000 series large core switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data-center OTV/LISP automation workflows.
-
Hyperscale Centralized Enterprise Tape Library Backup Fabric Aggregation Core
Deployed as dedicated backup SAN aggregation core director, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slots available for high-density host port expansion or M3 encryption/replication service line card additions as enterprise storage compliance requirements expand.
8. Standard Package Contents (Bare Chassis N77-C7718 Base SKU)
1 × N77-C7718 Nexus 7718 26RU empty modular switch chassis (front-to-back airflow, no factory pre-installed fans, supervisors, fabric modules, power supplies, I/O line cards)
19-inch standard 19-inch rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety & compliance documentation
Items Sold Separately (Mandatory Components Not Included in Bare Chassis)
-
Up to sixteen N77-AC-3KW-WS 3000W AC hot-swappable redundant power supply units (DC variant N77-DC-3KW-WS for telecom deployments, 3.5kW HV HVDC N77-HV-3.5KW-WS)
-
Two redundant N77-SUP2 / N77-SUP2E / N77-SUP3E fabric control modules (mandatory for full dual control-plane HA operation)
-
Up to six N77-C7718-FAB-2 crossbar fabric switching modules (six required for full 83 Tbps chassis bandwidth)
-
Three N77-C7718-FAN / FAN-2 hot-swappable multi-fan cooling trays (minimum two required for thermal compliance)
-
Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3/F4 switching module, N77-M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
-
SFP+/QSFP+/QSFP28 optical fiber transceivers for all base Ethernet/FCoE port interfaces (backward compatible with legacy 1G SFP transceivers)
-
Optional feature software licenses: IVR Inter-VSAN Routing, FCIP SAN Extension Enabler, Mainframe FCoE Enabler, OTV Data Center Interconnect, IOA I/O Acceleration, DMM Data Migration, MPLS XL Scale
-
RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories
Short Commercial Catalog Summary for Quotation
The Cisco N77-C7718 is an End-of-Sale 26RU ultra-large modular converged LAN/FCoE data center core switch bare chassis from the legacy Nexus 7700 Series 100G Generation, supplied bare without power supplies, fan trays, crossbar fabric modules, supervisor modules and pluggable Ethernet/FCoE I/O line cards (all FRUs sold separately). Built on an 83 Tbps non-blocking parallel crossbar fabric backplane with two dedicated half-slot Supervisor-2E dual redundant control slots plus sixteen universal hot-swappable I/O line card expansion slots supporting up to 192 total 100G QSFP28 ports (compatible with 10G SFP+ lossless FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow, up to sixteen hot-swappable 3000W Platinum high-efficiency AC redundant power supply bays, three independent interchangeable multi-fan cooling trays and complete OIR live FRU hot-swap maintenance support. Running legacy Cisco NX-OS multilayer converged LAN/SAN operating system, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic storage fabric routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, hardware FEC forward error correction, lossless FCoE convergence, FICON mainframe compatible storage integration, OTV cross-data-center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for hyperscale virtualized multi-pod data center core SAN aggregation, multi-building enterprise campus core-edge and large MPLS service provider multi-tenant PoP storage/LAN deployments with complete multi-N+1 power + triple layered fan + dual-supervisor + six-fabric-module full redundant hardware architecture; superior to smaller N77-C7702/7706/7710 compact pod core switches via sixteen I/O expansion slots, 192×100G maximum port density and mainstream front-to-back airflow design, limited by legacy maximum 100G Ethernet hardware generation, fixed I/O expansion ceiling and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS Level 3 and RoHS industrial standards.
|