Cisco N77-C7710-B26S2E Full Product Description

1. Short Overview

N77-C7710-B26S2Eis an official factory pre-populated hardware bundle for the Cisco Nexus 7710 14RU 10-slot large modular converged LAN/FCoE data center core switch chassis. This SKU integrates the base N77-C7710 empty chassis, one N77-SUP2E Supervisor 2E control module, and six full N77-C7710-FAB2 Fabric-2 crossbar modules pre-installed from factory; fan trays, power supplies, I/O line cards, optical transceivers and software feature licenses are sold separately. It runs NX-OS 8.x/9.x, delivers full 42 Tbps non-blocking parallel fabric capacity, native lossless FCoE SAN-LAN convergence, VDC multi-tenant virtual switching, OTV cross-DC overlay, LISP workload mobility, MPLS/EVPN carrier transport, complete OIR hot-swap FRU maintenance. The entire Nexus 7700 series reached End-of-Sale Oct 12, 2023; Final Hardware Support Expires Oct 31, 2028Cisco.

2. Official Bundle Composition & Suffix Decoding

Full Factory Pre-Integrated Hardware Included in N77-C7710-B26S2E

  1. N77-C7710 base 14RU 10-slot passive midplane empty chassis (no factory pre-installed fans, power supplies, I/O line cards)
  2. 1 × N77-SUP2E Supervisor 2E fabric/control module (preloaded into the half-slot supervisor Slot 5)
  3. 6 × N77-C7710-FAB2 Fabric-2 crossbar switching modules (all six rear fabric bays fully populated, full chassis fabric capacity)
  4. Standard 19-inch rack mounting rails, front cable management brackets, factory hardware installation & safety documentation

Items NOT Included (Must Purchase Separately)

  • Two independent hot-swappable fan trays (N77-C7710-FAN-S system fan + N77-C7710-FAN-F fabric dedicated fan)
  • Up to four N77-AC-3KW-WS / N77-DC-3KW-WS / N77-HV-3.5KW-WS 3kW/3.5kW AC/DC/HVDC redundant power supplies
  • F3/M3/F4 series I/O line/service modules for eight empty I/O slots
  • SFP+/QSFP+/QSFP28 optical transceivers for all port interfaces
  • Add-on software feature licenses (C1-N7710 XL scale, IVR, OTV, FCIP, FICON, MPLS XL scale, DMM, IOA Acceleration)
  • Optional accessories: Lockable front door, extended cable management kit, air filter kit

Suffix Meaning Breakdown

  • N77-C7710: Base 10-slot Nexus 7710 modular chassis identifier
  • B2: Pre-installed 2nd-generation Fabric modules (Fabric-2)
  • 6: Quantity of factory pre-loaded fabric modules = six Fabric-2 cards (all six fabric slots fully filled)
  • S2E: Single pre-installed Supervisor 2E control module (no second redundant supervisor included in this bundle)

3. Core Hardware Architecture & Key Differentiators vs N77-C7710-B23S2E (3-fabric variant)

Chassis Slot Layout (14RU 19-inch rack, fixed front-to-back cold aisle airflow only)

  1. Front Slots 1,2,3,4,7,8,9,10: Eight empty universal hot-swappable I/O line card slots (supports 10/40/100G F3/M3/F4 converged LAN/FCoE modules)
    • N77-F348XP-23: 48×10G SFP+ high-density F3 line card
    • N77-F324FQ-25: 24×40G QSFP+ F3 line card
    • N77-F312CK-26: 12×100G QSFP28 F3 max-density line card
    • N77-M348XP-23L: M3 multi-service 10G line card with FCIP/iSCSI gateway, L4-L7 traffic offload
  2. Slot 5: Half-size supervisor slot with factory pre-installed N77-SUP2E (Slot 6 empty; dual control-plane HA requires purchasing an extra N77-SUP2E separately)

Rear Redundant Subsystems (Fully Populated Fabric)

  1. Six N77-C7710-FAB2 Fabric-2 crossbar modules preloaded (all six fabric bays occupied, full 42 Tbps chassis throughput unlocked, no empty fabric slots left)
  2. Four empty hot-swappable power supply bays (3+1 N+1 redundant power design, PSUs sold separately)
  3. Two empty fan tray bays (system fan tray + dedicated fabric cooling fan tray, must order separately)

Core Hardware Advantages

  1. Pre-bundled chassis + single SUP2E + six full Fabric-2 modules to eliminate separate fabric module ordering, delivering maximum native chassis fabric capacity out of factory
  2. Massive eight I/O line card expansion slots, supporting up to 192×100G ports after adding full I/O modules
  3. Unified Nexus 7700 Gen3 module compatibility; all F3/M3/F4 I/O cards, Sup2/Sup2E interchangeable across all Nexus 7700 chassis to unify spare inventory cost
  4. Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe low-latency tunneling, full FICON zSystems storage integration without external gateway appliances

High-Availability Limitations of This Bundle

  • Only one supervisor pre-installed; full dual control-plane HA requires purchasing an extra N77-SUP2E to fill empty Slot 6 supervisor bay
  • No factory pre-installed fan trays or power supplies; full power/cooling redundancy requires separate PSU/fan tray procurement
  • Full OIR hot-swap maintenance supported for all FRUs (fabric modules, fan trays, power supplies, supervisor, I/O line card) with zero traffic interruption after all missing redundant hardware is deployed

4. Hardware Performance Specifications

Switching & Routing Capacity (6×Fab2 modules fully loaded, full chassis capacity)

  1. Full non-blocking fabric aggregate bandwidth: 42 Tbps full-duplex (maximum native throughput of N77-C7710 chassis)Cisco
  2. Wire-speed forwarding rate: Up to 42000 Mpps Ethernet frame switching at full 100G line rate
  3. Layer 2 MAC address table: 128,000 entries (XL software license required for extended scale)
  4. Layer 3 route scale: IPv4 unicast 128,000 entries; IPv6 unicast 64,000 entries; multicast routes 32,000 entries
  5. Maximum VDC virtual multi-tenant logical switch partitions: 8 independent isolated VDCs
  6. Port-channel limit: 1024 logical trunk bundles, maximum 16 physical ports per vPC/ISL link
  7. Native ASIC hardware offload suite:
    • Lossless FCoE stack: PFC priority flow control, DCBX, VNTag, FC-NVMe ultra-low-latency tunneling
    • OTV cross-data-center encapsulation, LISP endpoint mapping
    • FCIP tunnel compression, write acceleration, tape pipelining for long-distance DR backup replication
    • DMM non-disruptive data migration, IOA storage I/O acceleration, onboard streaming telemetry export

Supervisor-2E (N77-SUP2E) Core Specs

Dual-core x86 enterprise CPU, 16GB DRAM, 16GB internal compact flash storage
Dual 1G out-of-band management Ethernet ports, RS232 serial + mini USB dual local console ports
External USB flash port for NX-OS image/config backup and offline diagnostics
Dedicated onboard NPU for real-time streaming LAN/SAN performance telemetry export

Physical & Environmental Parameters

  • Rack height: 14 RU (61.9cm tall), standard 19-inch EIA horizontal rack mount
  • Dimensions (H × W × D): 61.9 cm × 43.9 cm × 86.4 cm; extended depth 98.8cm with cable management kit installed
  • Bundle weight (chassis + 1×SUP2E + six Fabric-2 modules, no fans/PSUs/I/O cards): ~90 kg (198 lbs)
  • Fully loaded maximum weight (four AC PSUs + two fan trays + six fabric modules + dual supervisors + eight 48-port 100G I/O line cards): ~138kg (304lbs)
  • Operating temperature range: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 4000m
  • Humidity: 8%–80% non-condensing operating; 5%–90% non-condensing storage
  • Compliance certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic Zone 4, RoHS, FIPS 140-2 Level 2 validated

Airflow Specification

Fixed front-to-back airflow: Cold air flows into front panel, hot air exhausted from rear power/fabric compartment (standard mainstream cold aisle data center rack design; no reverse hot-aisle exhaust chassis variant)

5. Full NX-OS Feature Set Supported

Layer 2 Ethernet & Converged FCoE Storage Fabric

  • VDC Virtual Device Context: Logical multi-tenant isolation to separate production/test/backup LAN/SAN workloads (8 independent VDCs)
  • 4094 VLANs per VDC, PVLAN private VLAN anti-spoofing isolation
  • Complete lossless FCoE protocol stack: VSAN storage fabrics, hard WWN zoning, Auto-Zone automatic fabric provisioning, FC-NVMe low-latency forwarding
  • MSTP multi-instance spanning tree loop prevention, vPC dual-active peer-link redundancy, SPAN/RSPAN remote traffic mirroring for multi-session performance troubleshooting
  • NPV/NPIV FCoE edge virtualization to reduce upstream MDS SAN fabric control-plane load
  • Slow drain detection and buffer credit congestion isolation hardware feature to eliminate packet loss for lossless storage traffic
  • POAP Power On Auto Provisioning zero-touch automatic switch deployment for mass rack rollouts

Multilayer Routing & Cross-Data Center Interconnect Features

  • Dynamic IPv4/IPv6 routing protocols: OSPF, EIGRP, BGP
  • VRF virtual routing and forwarding multi-tenant Layer 3 isolation
  • Licensed IVR Inter-VSAN Routing for secure cross-storage-fabric data forwarding
  • OTV Overlay Transport Virtualization: Layer 2 workload mobility for geographically separated disaster recovery data centers
  • LISP Locator/ID Separation Protocol: Multi-pod workload mobility across distributed data center sites
  • Full carrier-grade MPLS suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
  • FCIP tunnel hardware acceleration: Lossless compression, write acceleration, tape pipelining for long-distance off-site tape backup replication
  • iSCSI multi-protocol gateway processing via M3 service line cards for IP-attached server consolidation

Advanced QoS & Traffic Prioritization

  • Four hardware priority queues per Ethernet/FCoE port for tiered classification of storage I/O, virtual machine east-west traffic, management and backup streams
  • Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication traffic
  • Pre-built QoS templates optimized for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
  • Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
  • DCBX media optimization for converged FCoE LAN/SAN traffic prioritization over 10/40/100G ports

Enterprise & Service Provider Security Suite

  • Port security: Static MAC locking to block unauthorized physical server/storage device attachment
  • RBAC granular multi-tier administrative access control, integrated with Cisco ISE identity services engine
  • SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
  • Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
  • FIPS 140-2 Level 2 compliance for government, financial and regulated enterprise deployments
  • Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
  • IPv6 over Fibre Channel support for modern dual-stack management networks
  • Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering

Monitoring & SAN/LAN Management Tools

  • Cisco DCNM centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
  • Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
  • External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
  • Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
  • Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
  • Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
  • GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption
  • Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts

6. Typical Deployment Scenarios for N77-C7710-B26S2E Full-Fabric Bundle

  1. Large virtualized multi-pod hyperscale data center core aggregation: Full 42 Tbps non-blocking capacity supports 192×100G ports connecting distributed building N77-C7706 medium core switches, massive all-flash NVMe FCoE storage arrays and high-density blade server racks; VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN logical fabrics
  2. Multi-building enterprise campus core-edge SAN-LAN fabric: Multiple N77-C7710-B26S2E large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods; built-in FCIP hardware offload provisions asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers
  3. Large regional mission-critical headquarters converged storage/LAN switch: Financial, healthcare and government headquarters deployments require complete full-fabric hardware capacity, paired with a second identical N77-C7710-B26S2E peer switch for dual-chassis vPC HA to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant logical switch partitioning supports mixed enterprise and agency workloads on a single large chassis
  4. Medium-Large MPLS service provider multi-tenant metro PoP edge gateway: Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N77-C7710-B26S2E ideal for large metro PoP edge deployments, terminating large-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and L4-L7 service M3 line card upgrades
  5. Legacy large-scale SAN-LAN fabric consolidation migration director: Drop-in performance upgrade for aging Nexus 7000 series large core switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data-center OTV/LISP automation workflows
  6. Hyperscale centralized enterprise tape library backup fabric aggregation core: Dedicated backup SAN aggregation core switch utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slots available for high-density host port expansion or M3 encryption/replication service line card additions as enterprise storage compliance requirements expand

7. Standard Package Contents of N77-C7710-B26S2E Factory Bundle

1 × N77-C7710 Nexus 7710 14RU empty modular switch chassis (front-to-back airflow, integrated multi-fan tray bay empty, no pre-installed fans, power supplies, I/O line cards)
1 × N77-SUP2E Supervisor 2E control module (preloaded into Slot 5 supervisor bay)
6 × N77-C7710-FAB2 Fabric-2 crossbar fabric switching modules (all six rear fabric bays fully populated)
19-inch standard 19-inch rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation

Separately Mandatory Components (Not Included in This Bundle)

  • Two N77-C7710-FAN series hot-swappable multi-fan cooling trays (system fan tray + dedicated fabric fan tray)
  • Dual / triple / quad N77-AC-3KW-WS 3000W AC hot-swappable redundant power supply units (DC variant N77-DC-3KW-WS for telecom deployments, 3.5kW HV HVDC N77-HV-3.5KW-WS)
  • Optional second N77-SUP2E supervisor control module (to achieve native dual control-plane HA operation)
  • Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3/F4 switching module, N77-M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
  • SFP+/QSFP+/QSFP28 optical fiber transceivers for all base Ethernet/FCoE port interfaces (backward compatible with legacy 1G SFP transceivers)
  • Optional feature software licenses: C1-N7710 XL Scale, IVR Inter-VSAN Routing, FCIP SAN Extension Enabler, Mainframe FCoE Enabler, OTV Data Center Interconnect, IOA I/O Acceleration, DMM Data Migration, MPLS XL Scale
  • RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, locking front door, air filter kit

Short Commercial Catalog Summary

The Cisco N77-C7710-B26S2E is an End-of-Sale pre-assembled hardware factory bundle of the 14RU 10-slot Nexus 7710 modular converged LAN/FCoE data center core switch. The factory bundle includes the N77-C7710 bare chassis, one pre-installed N77-SUP2E Supervisor 2E control module and six factory preloaded Fabric-2 crossbar modules (full 42 Tbps maximum chassis fabric capacity); fan trays, power supplies, I/O line cards, optical transceivers and software feature licenses must be ordered separately. It uses a parallel crossbar distributed fabric delivering full 42 Tbps non-blocking throughput, runs modern NX-OS 8.x/9.x with complete VDC multi-tenant virtualization, lossless FCoE SAN-LAN convergence, OTV cross-data-center overlay, LISP workload mobility and full OIR hot-swap maintenance support. Optimized for large virtualized multi-pod data center core aggregation, multi-building enterprise campus core-edge and large MPLS service provider multi-tenant PoP deployments with complete full-fabric hardware capacity, limited by single factory supervisor (no native dual control-plane redundancy), missing pre-installed power/cooling hardware, legacy maximum 100G Ethernet hardware generation and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS Level 3 and RoHS industrial standards.