Cisco N77-C7710-40G Full Product Description
Critical Clarification
There is no official standalone hardware chassis PID namedN77-C7710-40Gon Cisco’s global product catalog. This identifier is a custom short-name used in bid/engineering scenarios to represent afully populated N77-C7710 10-slot Nexus 7710 chassis optimized for 40G QSFP+ port density deployments, with all hardware base identical to standard N77-C7710 bare chassis; the "-40G" suffix only indicates the deployment target (40G dominant workloads), not a separate physical hardware variant.
1. Short Overview
N77-C7710-40G is a deployment-oriented designation for the Cisco Nexus 7710 14RU large modular converged LAN/FCoE core switch, configured for high-density 40G QSFP+ uplink/host storage fabrics. The underlying hardware platform is the standard N77-C7710 10-slot front-to-back airflow chassis, supporting F3/M3 series 24×40G I/O line cards, dual Supervisor-2E, six Fabric-2/Fabric-3 crossbar modules, triple redundant fan trays, up to four 3kW AC power supplies. Full non-blocking fabric capacity up to 42 Tbps full-duplex, maximum native 40G port count: 192×40G (8× N77-F324FQ-25 24-port 40G line cards). It runs NX-OS 8.x/9.x, natively supports lossless FCoE SAN-LAN convergence, VDC multi-tenant virtual switching, OTV cross-DC overlay, LISP workload mobility, MPLS/EVPN carrier transport, complete OIR hot-swap FRU maintenance. End-of-Sale Oct 12, 2023; Final Hardware Support Expires Oct 31, 2028.
2. Definition of N77-C7710-40G
1) Physical hardware identical to base N77-C7710 bare chassis
-
Form factor: 14RU 10-slot front panel modular switch
-
Front slots: 8 full universal I/O line card slots + 2 half-slot redundant supervisor slots
-
Rear: Six hot-swappable crossbar fabric module bays, four power supply bays, two independent fan trays
-
Airflow: Fixed front-to-back cold aisle intake (no hardware difference vs standard N77-C7710)
2) What "-40G" Represents (Deployment Configuration Rules)
-
All I/O line cards deployed are 40G-dominant F3/M3 modules: N77-F324FQ-25 (24×40G QSFP+)
-
No 100G F4 line cards used in this "40G" targeted build; prioritizes 40G leaf-spine, FCoE storage uplinks, campus 40G aggregation
-
Full 40G transceiver support: QSFP-40G-SR4/LR4/CSR4/ER4, 40G active/passive QSFP break-out cables
-
Optimized buffer mode on M3 line cards for 40G high-concurrency lossless FCoE traffic
-
Software XL license enabled for extended MAC/route table scale to support large 40G multi-tenant fabrics
3. Components Not Included in Bare Chassis (Must Be Ordered Separately)
-
Dual N77-SUP2E Supervisor 2E control modules
-
Six N77-C7710-FAB-2 / FAB-3 crossbar fabric modules
-
Three N77-C7710-FAN series fan trays
-
Up to four N77-AC-3KW-WS 3kW AC redundant power supplies
-
Eight N77-F324FQ-25 24-port 40G I/O line cards (max full 40G port density)
-
QSFP+ 40G optical transceivers, break-out cables
-
Feature licenses: C1-N7702 XL scale, IVR, OTV, FCIP, FICON, MPLS
3. Chassis Hardware & Slot Layout (Same as N77-C7710)
Front Panel 10 Horizontal Slots (14RU 19-inch rack)
-
Slots 1,2,3,4,7,8,9,10: Eight universal I/O line card slots (40G primary for N77-C7710-40G build):
-
N77-F324FQ-25: 24×40G QSFP+ F3 line card (standard for this 40G chassis configuration)
-
N77-M324FQ-25L: M3 multi-service 24×40G line card with FCIP/iSCSI gateway, L4-L7 offload
-
Slots 5,6: Dual half-slot N77-SUP2E supervisor slots (active/standby redundant control plane)
Rear Redundant Subsystems
-
Six N77-C7710-FAB-2/FAB-3 fabric module slots (464Gbps per slot Fabric-3, 42 Tbps full capacity)
-
Four hot-swappable 3kW AC power supply bays (3+1 N+1 redundant power)
-
Two independent hot-swappable multi-fan trays (system fan + dedicated fabric cooling fan tray)
Airflow & Management Interfaces
-
Airflow: Front-to-back cold air intake, rear hot exhaust (standard enterprise cold aisle design)
-
Per-supervisor management ports: Dual 1G out-of-band Ethernet, RS232 serial, mini USB local console, external USB flash storage
-
Front panel LED array: Chassis health, power, fan, fabric, supervisor, I/O port link status, UID beacon
4. Key Performance Specs (40G-Optimized Configuration)
-
Full-chassis non-blocking fabric bandwidth: 42 Tbps full-duplex (six Fabric-3 modules fully populated)
-
Wire-speed forwarding rate: 42000 Mpps at full 40G line rate
-
Max 40G port capacity: 8 × 24 = 192 × 40G QSFP+ ports (no 100G line cards deployed in this -40G configuration)
-
Layer 2 MAC table: 128,000 entries (XL license enabled)
-
Layer 3 route scale: IPv4 128,000 / IPv6 64,000 / multicast 32,000 entries
-
VDC multi-tenant partitions: 8 independent logical switch domains
-
Port-channels: 1024 logical trunks, maximum 16 physical ports per vPC/ISL bundle
-
Native hardware offload suite for 40G/FCoE workloads:
-
Lossless FCoE stack: PFC, DCBX, VNTag, FC-NVMe low-latency tunneling
-
OTV cross-DC encapsulation, LISP endpoint mapping
-
FCIP tunnel compression, tape pipelining for long-distance backup replication
-
DMM non-disruptive data migration, IOA storage I/O acceleration
Supervisor-2E Core Specs
Dual-core x86 CPU, 16GB DRAM, 16GB compact flash, dual 1G out-of-band management Ethernet, dedicated streaming telemetry NPU for 40G fabric performance monitoring
Physical & Environmental Parameters
-
Rack height: 14 RU (61.9cm tall), standard 19-inch EIA horizontal rack mount
-
Full loaded weight (4×AC PSUs + two fan trays + six fabric modules + dual supervisors + eight 40G line cards): ~138kg (304lbs)
-
Operating temperature: 0°C ~ 40°C; certified altitude up to 4000m
-
Humidity: 8%–80% non-condensing operating
-
Compliance: FCC Class A, UL 60950-1, CE, NEBS Level 3, GR63 seismic Zone 4, RoHS, FIPS 140-2 Level 2
5. Full NX-OS Feature Set Enabled for N77-C7710-40G 40G Fabric Deployments
Layer 2 & Converged FCoE Storage Fabric
-
VDC virtual multi-tenant isolation (8 independent VDCs)
-
4094 VLANs per VDC, PVLAN anti-spoofing isolation
-
Complete lossless FCoE protocol stack: VSAN storage fabrics, hard WWN zoning, Auto-Zone auto-provisioning, FC-NVMe low-latency forwarding over 40G QSFP+
-
MSTP spanning tree loop prevention, vPC dual-active peer-link redundancy, SPAN/RSPAN remote traffic analytics
-
NPV/NPIV FCoE edge virtualization to reduce upstream MDS SAN fabric load
-
Slow drain detection and buffer credit congestion isolation for 40G high-concurrency storage traffic
-
POAP zero-touch automatic switch provisioning for mass rack rollouts
Multilayer Routing & Cross-DC Interconnect
-
OSPF / EIGRP / BGP IPv4/IPv6 dynamic routing, VRF multi-tenant Layer 3 isolation
-
Licensed IVR Inter-VSAN Routing for cross-storage-fabric data forwarding over 40G uplinks
-
OTV Overlay Transport Virtualization: Layer 2 workload mobility across geographically separated data centers
-
LISP Locator/ID Separation Protocol: Multi-pod workload mobility
-
Full carrier-grade MPLS suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
-
FCIP tunnel hardware acceleration: Lossless compression, write acceleration, tape pipelining for long-distance off-site tape backup replication via 40G inter-DC links
-
M3 40G service line card support for iSCSI multi-protocol gateway and L4-L7 traffic offload
QoS, Security & Automation
-
Four hardware priority queues per 40G/FCoE port for tiered classification of storage I/O, VM east-west traffic, management and backup streams
-
Ingress policing + egress bandwidth shaping to throttle low-priority tape backup/replication traffic
-
Pre-built QoS templates optimized for 40G all-flash NVMe storage workloads, virtual server east-west traffic, disaster recovery replication
-
Dedicated high-priority queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization over 40G QSFP+ ports
-
RBAC granular multi-tier admin access control, Cisco ISE identity services engine integration
-
SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
-
FIPS 140-2 Level 2 compliance for financial, government and regulated enterprise deployments
-
Cisco DCNM centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
-
GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption
-
Real-time streaming telemetry export for 40G fabric throughput, latency and error monitoring
6. High Availability Architecture (Identical to Standard N77-C7710)
-
Dual native redundant Supervisor-2E control modules with stateful failover and non-disruptive ISSU firmware upgrades
-
Eight universal I/O line card expansion slots supporting full 192×40G port density
-
Six independent active-active load-sharing crossbar fabric modules delivering 42 Tbps non-blocking throughput
-
Up to four hot-swappable 3kW AC redundant power supplies (3+1 N+1 power redundancy)
-
Two separate independent hot-swappable fan trays for layered redundant cooling
-
Full OIR hot-swap maintenance support for all FRUs (fabric modules, fan trays, power supplies, supervisors, I/O line cards) without chassis power cycle
-
Front-to-back airflow design compatible with mainstream enterprise cold aisle rack layouts
-
Unified NX-OS feature parity with all Nexus 7700 family chassis
7. Typical Deployment Scenarios for N77-C7710-40G (40G-Optimized Build)
-
Large virtualized multi-pod data center core aggregation: 192×40G ports connect leaf Nexus 2000 FEX extenders, medium-scale all-flash NVMe FCoE storage arrays and high-density blade server racks; VDC + VSAN segmentation isolates production/test/backup logical fabrics
-
Multi-building enterprise campus core-edge converged switch: 40G inter-building ISL trunk links, built-in FCIP hardware offload provides asynchronous disaster recovery replication between primary and DR data centers
-
Medium-to-large financial/mainframe zSystems storage core: Native FCoE + FICON compatibility enables long-distance 40G FCIP tape backup replication; dual-chassis vPC peer architecture eliminates single point of failure
-
Medium MPLS service provider multi-tenant metro PoP edge gateway: VDC multi-tenant logical switch partitioning separates independent enterprise customer LAN/SAN fabrics on a single chassis, 40G core uplinks to provider backbone
-
Legacy Nexus 7000 40G fabric migration upgrade: Backward compatible with existing 40G QSFP+ transceivers while unlocking larger MAC/route tables, VDC virtual multi-tenant partitioning and modern NX-OS OTV/LISP cross-data-center automation workflows
-
Centralized enterprise tape library backup fabric aggregation core: Dedicated backup fabric switch using multi-port 40G FCIP PortChannel trunks to primary production FCoE SAN fabrics for asynchronous off-site tape archive replication workloads
8. Package & Ordering Clarification
-
N77-C7710-40G is a deployment configuration label, not a standalone orderable PID
-
Base physical chassis part number: N77-C7710 (bare empty frame)
-
Required components to build full N77-C7710-40G 40G optimized switch:
1 × N77-C7710 bare chassis
2 × N77-SUP2E Supervisor 2E
6 × N77-C7710-FAB-3 Fabric-3 crossbar modules
2 × N77-C7710-FAN fan trays
3–4 × N77-AC-3KW-WS 3kW AC power supplies
8 × N77-F324FQ-25 24-port 40G I/O line cards
C1-N7710 XL scale feature license + add-on feature licenses (OTV, FCIP, FICON, MPLS)
SFP+/QSFP+ 40G optical transceivers, patch cables, rack mounting rails, cable management accessories
Short Commercial Summary
N77-C7710-40G is a custom deployment designation for the Cisco Nexus 7710 14RU 10-slot modular converged LAN/FCoE data center core switch, configured exclusively for high-density 40G QSFP+ port workloads. The physical hardware chassis, slot layout, fabric, power, cooling and airflow are identical to standard N77-C7710 bare chassis; the "-40G" suffix only indicates the deployment targets 40G leaf-spine, FCoE storage and campus aggregation, with all I/O line cards populated as 24-port 40G F3/M3 modules to reach maximum 192×40G port density. It runs legacy NX-OS 8.x/9.x with XL scalable feature license enabled, delivering VDC multi-tenant virtualization, lossless FCoE SAN-LAN convergence, OTV cross-data-center overlay, LISP workload mobility and full OIR hot-swap maintenance support. The underlying chassis hardware is End-of-Sale Oct 12, 2023 with hardware support expiring Oct 31, 2028, compliant with global safety, EMI, NEBS Level 3 and RoHS industrial standards.
|