N77-C7710
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco N77-C7710 (Nexus 7710) Full Product Description

1. Short Overview

Cisco N77-C7710 is a 14RU large modular converged LAN/FCoE data center core switch bare chassis from the Cisco Nexus 7700 next-gen 100G platform, released 2014, End-of-Sale Oct 12, 2023, Final Hardware Support Expires Feb 28, 2028. It features a 10-slot front midplane, dual native redundant Supervisor half-slots + 8 universal full I/O line card slots, rear-mounted six hot-swappable Fabric-2/Fabric-3 crossbar modules, front-to-back airflow, three independent hot-swappable fan trays, up to four 3kW / 3.5kW AC/DC power supplies (3+1 N+1 redundancy). Maximum full-chassis non-blocking throughput reaches42 Tbps full-duplexwith Fabric-3 modules fully loaded, peak port density: 768×10G, 384×40G, 192×100G Ethernet/FCoE ports. It runs NX-OS 8.x/9.x, natively supports lossless FCoE SAN-LAN convergence, VDC multi-tenant virtual switching, OTV cross-DC overlay, LISP workload mobility, full MPLS/EVPN carrier transport, complete OIR hot-swap FRU maintenance. Targeted for hyperscale enterprise data center core, multi-pod campus aggregation, large service provider multi-tenant PoP border, unified end-to-end SAN-LAN fabric and cross-region disaster recovery workloadsCisco.

2. Official Lifecycle & Chassis Definition

  • Bare chassis PN:N77-C7710(empty frame without supervisors, fabric modules, power supplies, I/O line cards, transceivers; bundled SKUs like N77-C7710-B24S2E ship pre-populated with core hardware)
  • EOL Timeline: EOS Oct 12, 2023; Final Hardware Support Oct 31, 2028

Core Hardware Differentiators vs N77-C7702 / N77-C7706 smaller chassis

  1. Massive I/O expansion scale: 8 universal full I/O line card slots (N77-C7702 only 1, N77-C7706 only 4), peak 192×100G ports vs 12×100G on 7702 / 48×100G on 7706Cisco
  2. High-capacity external rear fabric subsystem: Six dedicated N77-C7710-FAB-2/FAB-3 fabric module slots (active-active parallel load-sharing, scalable total fabric bandwidth up to 42 Tbps); small 7702 uses embedded distributed fabric ASICs on I/O cards with no separate fabric modules and only 2.4 Tbps total capacity; 7706 max 21 TbpsCisco
  3. Dual native half-slot supervisor slots (built-in full control-plane redundancy, supports dual Sup2/Sup2E out of box; N77-C7702 only single supervisor slot with no second native bay)
  4. Three independent hot-swappable fan trays (layered redundant cooling; N77-C7702 single integrated fan tray, N77-C7706 triple fans but smaller chassis cooling volume)Cisco
  5. Up to four hot-swappable power supply bays (3+1 N+1 power redundancy; 7706 max triple PSUs, 7702 only dual PSUs)
  6. Standard front-to-back cold aisle airflow (industry mainstream design, compatible with all standard data center rack layouts; 7702 uses side-to-back airflow with limited rack compatibility)Cisco
  7. Unified Nexus 7700 Gen3 module compatibility: All F3/M3/F4 10/40/100G I/O line cards, Sup2/Sup2E supervisors fully interchangeable across all Nexus 7700 chassis to unify spare inventory cost
  8. Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe low-latency tunneling, full FICON zSystems storage integration without external gateway appliances

Core High-Availability Design

All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live maintenance without data plane outage. Up to four identical 3000W / 3500W Platinum AC/DC power supplies deliver N+1 redundant power operation; three independent multi-fan trays provide layered chassis cooling, single fan tray failure triggers SNMP alert without immediate traffic shutdown. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context partitions multi-tenant LAN workloads to prevent broadcast storm leakage across logical domains. NPV/NPIV edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Dual supervisor modules (Slot5 active, Slot6 standby) maintain full stateful synchronization, zero-I/O-loss automatic failover and non-disruptive ISSU firmware upgrades. Six independent crossbar fabric modules operate in parallel load-sharing mode; removing any single fabric module does not degrade overall chassis throughput capacity.
Target deployment scenarios: Hyperscale virtualized multi-pod data center core SAN-LAN aggregation, multi-building enterprise campus distributed storage root, large regional mission-critical cross-site disaster recovery SAN gateway, large MPLS service provider multi-tenant PoP edge border switch, unified campus-wide SAN-LAN fabrics interoperable with N77-C7702 compact pod core switches, N77-C7706 mid-size core directors and MDS 9000 SAN directors.

Model Suffix Breakdown

  • N77: Nexus 7700 next-gen 100G modular data center switch platform prefix
  • C7710: Bare empty 10-slot front chassis (8 I/O line card slots + 2 half-slot supervisor slots) + rear six fabric module slots
  • Bare chassis N77-C7710 has no K9 suffix; pre-bundled hardware SKUs with supervisors/power supplies carry -2K9 / -B24S2E suffix
  • Airflow fixed front-to-back cold intake (no separate E hot-aisle exhaust chassis variant)

3. Chassis Slot & Hardware Layout Definition

Front Panel 10 Horizontal Slots (14RU 19-inch rack)

  1. Slots 1,2,3,4,7,8,9,10: Eight universal hot-swappable I/O line/service module slots (F3/M3/F4 10/40/100G Ethernet/FCoE switching cards, DS-X9334 FCIP multi-protocol extension modules, SSM encryption/asynchronous replication service modules)
    • N77-F348XP-23: 48×10G SFP+ high-density F3 series line card
    • N77-F324FQ-25: 24×40G QSFP+ F3 series line card
    • N77-F312CK-26: 12×100G QSFP28 F3 maximum-density line card (max 192×100G ports full chassis)
    • N77-M348XP-23L: M3 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
    • N77-F430CQ-36: F4 next-gen 30×100G high-density line card
  2. Slots 5,6: Dedicated half-slot Supervisor-2E / Supervisor-2 fabric control module slots (dual redundant native to chassis, active/standby deployment standard)

Rear Panel Redundant Subsystems

  1. Up to six independent hot-swappable N77-C7710-FAB-2 / FAB-3 crossbar fabric switching modules (464Gbps per slot per Fabric-3 module, parallel load-sharing for scalable 42 Tbps total throughput)
  2. Four independent hot-swappable power supply bays supporting AC 3kW / 3.5kW HV HVDC / DC 3kW power modules (3+1 N+1 redundant power protection)
  3. Three independent hot-swappable multi-fan variable-speed fan tray bays (N77-C7710-FAN Gen1 / N77-C7710-FAN-2 Gen2 high-airflow fan trays)Cisco

Out-of-Band Management Interfaces (each Supervisor module carries full management ports)

  • RJ45 RS232 serial console port for local CLI access
  • Mini USB dual local console port for laptop zero-cable administration
  • Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export dedicated interface)
  • External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
  • Physical reset button for factory default configuration recovery

Front Global Diagnostic LED Bank

Chassis system health status, power supply A/B/C/D, triple rear fan tray fault indicators, six fabric module status, dual supervisor module health, eight I/O line card port link activity, hardware fault alarm, UID locator beacon LED

Airflow Specification

Fixed front-to-back airflow: Cold air intake from front panel side, hot air exhausted from rear power/fabric compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N77-C7710)Cisco

Supported Transceivers & Pluggable Modules

  1. Ethernet/FCoE optical transceivers (sold separately for all line card ports):
    • SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
    • QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
    • QSFP28: 100G-SR4/LR4 for 100G high-density uplink/host ports
    • Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
  2. Supervisor module compatibility: Supervisor-2 (N77-SUP2), Supervisor-2E (N77-SUP2E upgraded larger memory, enhanced FCoE telemetry NPU, Secure Boot)
  3. Fabric module compatibility: N77-C7710-FAB-2 Generation2 crossbar fabric modules, N77-C7710-FAB-3 Generation3 high-bandwidth fabric modules (six FAB-3 required for full 42 Tbps chassis bandwidth)
  4. Power supply compatibility: 3000W AC PEM modules (N77-AC-3KW-WS), 3000W DC PEM telecom modules (N77-DC-3KW-WS), 3.5kW HV HVDC power supplies (N77-HV-3.5KW-WS), non-interchangeable between AC/HV chassis variants

4. Hardware & Physical Performance Specifications

Core Switching & Routing Performance

  1. Full-chassis parallel crossbar fabric maximum aggregate bandwidth: 42 Tbps full-duplex system-wide throughput with six Fabric-3 modules fully loadedCisco
  2. Wire-speed frame forwarding rate: Up to 42000 Mpps Ethernet frame switching at full 100G line rate
  3. Low-latency distributed shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
  4. MAC address table capacity: 128,000 MAC entries
  5. IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
  6. Maximum isolated VDC virtual switch contexts: 8 independent logical switch partitions + 1 admin VDC
  7. Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
  8. Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
  9. NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
  10. Native multi-protocol ASIC hardware offload feature set: FC-NVMe ultra-low-latency frame tunneling, FCoE lossless PFC/DCBX/VNTag processing, vPC peer synchronization, OTV cross-DC encapsulation, LISP endpoint mapping, FCIP tunnel compression/tape pipelining, DMM non-disruptive data migration, IOA storage I/O acceleration, onboard streaming telemetry export

Power & Cooling System

  • Power supply bays: 4 hot-swappable redundant slots, each 3000W AC PSU fully powers complete chassis independently (3+1 failover protection)
  • AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal alternating current, 80 Plus Platinum high efficiency
  • Fan trays: Three independent hot-swappable multi-fan variable-speed assemblies; minimum two full fan trays functional to avoid thermal shutdown, single fan tray failure triggers SNMP fault alert
  • Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C short-term emergency operation
  • Typical full-load power draw: 510W fully populated with eight 48-port 100G line cards + dual supervisors + six fabric modules + four AC power supplies under maximum traffic load
  • MTBF: 200,000 hours under standard enterprise data center operating conditions

Physical & Environmental Parameters

  • Rack form factor: 14 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 61.9 cm × 43.9 cm × 86.4 cm (14 rack units, 17.3 × 34.0 inch depth; extended depth 98.8cm with cable management guide installed)Cisco
  • Bare chassis weight (N77-C7710 empty frame only, no fans/PSUs/supervisors/fabric/line cards): 90 kg (198 lbs)
  • Fully loaded maximum weight (four AC PSUs + three fan trays + six fabric modules + dual supervisors + eight 48-port 100G line cards): ~138 kg (304 lbs)
  • Operating ambient temperature range: 0°C to 40°C (32°F to 104°F); certified altitude up to 4000m
  • Storage temperature range: -40°C to 70°C (-40°F to 158°F)
  • Relative humidity: 8%–80% non-condensing operating; 5%–90% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic Zone 4, RoHS, FIPS 140-2 Level 2 validated

Supervisor-2E (N77-SUP2E) Built-in Specs

  • Dual-core x86 enterprise CPU, 16GB DRAM, 16GB internal compact flash storage
  • Dual 1G out-of-band management Ethernet ports, RS232 serial + mini USB local console
  • External USB flash port for NX-OS image/config backup
  • Dedicated streaming telemetry NPU for real-time LAN/SAN performance analytics export

5. Full NX-OS Feature Set Supported

Layer 2 Ethernet & Converged FCoE Storage Fabric

  • VDC Virtual Device Context: Logical multi-tenant isolation to separate production/test/backup LAN/SAN workloads on single physical chassis (8 independent VDCs)
  • 4094 VLANs per VDC, PVLAN private VLAN anti-spoofing isolation
  • Complete lossless FCoE stack: VSAN storage fabrics, hard WWN zoning, Auto-Zone auto-provisioning, FC-NVMe low-latency forwarding
  • MSTP multi-instance spanning tree loop prevention, vPC dual-active peer-link redundancy, SPAN/RSPAN remote traffic analytics
  • NPV/NPIV FCoE edge virtualization to reduce MDS SAN fabric control-plane load
  • Slow drain detection and buffer credit congestion isolation for lossless storage traffic
  • POAP Power On Auto Provisioning zero-touch automatic switch deployment for mass rack rollouts

Multilayer Routing & Cross-DC Interconnect Features

  • OSPF / EIGRP / BGP IPv4/IPv6 dynamic routing, VRF multi-tenant routing separation
  • Licensed IVR Inter-VSAN Routing for cross-storage-fabric data forwarding
  • OTV Overlay Transport Virtualization: Layer 2 workload mobility for disaster recovery cross-DC deployments
  • LISP Locator/ID Separation Protocol: Multi-pod workload mobility across geographically distributed data centers
  • Full carrier-grade MPLS suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
  • FCIP tunnel hardware acceleration: Compression, write acceleration, tape pipelining for long-distance off-site tape backup replication
  • iSCSI multi-protocol gateway processing via M3 service line cards for IP-attached server consolidation

Advanced QoS & Traffic Prioritization

  • Four hardware priority queues per Ethernet/FCoE port for tiered classification of storage I/O, VM east-west traffic, management, backup streams
  • Ingress policing + egress bandwidth shaping to throttle low-priority backup/replication traffic
  • Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
  • Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
  • DCBX media optimization for converged FCoE LAN/SAN traffic prioritization

Enterprise & Service Provider Security Suite

  • Port security: Static MAC locking to block unauthorized physical server/storage device attachment
  • RBAC granular multi-tier admin access control, Cisco ISE identity services engine integration
  • SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
  • FIPS 140-2 Level 2 compliance for financial, government and regulated enterprise deployments
  • Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
  • IPv6 over Fibre Channel support for modern dual-stack management networks
  • Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering

Monitoring & SAN/LAN Management Tools

  • Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
  • Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
  • External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
  • Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
  • Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
  • Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
  • GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption
  • Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts

6. High Availability Capabilities (Core Differentiators vs N77-C7706 Mid-Size 6-Slot Director)

  1. Dual redundant Supervisor-2 / Supervisor-2E fabric control modules with stateful failover and ISSU non-disruptive firmware upgrades (shared HA architecture with all Nexus 7700 chassis)
  2. Eight universal I/O line card expansion slots vs four on N77-C7706, maximum port density 192×100G vs 48×100G on 7706
  3. Six independent active-active load-sharing crossbar fabric modules delivering 42 Tbps full non-blocking throughput (N77-C7706 max 21 Tbps total bandwidth)
  4. Up to four hot-swappable high-efficiency 3kW AC redundant power supplies (3+1 N+1 triple+1 power redundancy; N77-C7706 only three PSUs with limited 2+1 redundancy)
  5. Three independent layered hot-swappable fan trays with multi-fan fault tolerance (shared cooling architecture with N77-C7706, larger chassis cooling volume for full eight I/O card load)
  6. Full OIR hot-swap support for all critical FRUs: fabric modules, fan trays, power supplies, supervisors, line cards without chassis power cycle
  7. Front-to-back airflow design compatible with mainstream enterprise cold aisle rack deployments (shared airflow standard with all large Nexus 7700 chassis)
  8. Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation feature set fully consistent across Nexus 7700 family
  9. 14RU rack footprint for large core aggregation deployments (N77-C7706 is 9RU, smaller rack height for medium core deployments)
  10. Limitation: Fixed eight I/O slot ceiling with no expansion beyond built-in line card bays, legacy maximum 100G Ethernet hardware generation, end-of-sale since Oct 12, 2023, hardware support expiring Oct 31, 2028.

7. Typical Deployment Scenarios

  1. Large Virtualized Multi-Pod Data Center Core SAN-LAN Director
    14RU modular rack form factor deployed as campus central SAN/LAN core aggregation director; eight 48-port 100G F3/F4 line cards populate all I/O slots for 192 total 100G ports connecting distributed building N77-C7706 medium core switches, massive all-flash NVMe FCoE storage arrays and high-density blade server racks, dual redundant supervisors + six active fabric modules deliver zero-failover fabric reliability, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN logical fabrics.
  2. Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
    Multiple N77-C7710 large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, triple redundant fan trays + four redundant power supplies ensure stable cooling/power during hardware maintenance, built-in FCIP hardware offload provision asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
  3. Large Regional Mission-Critical Headquarters Converged Storage/LAN Switch
    Financial, healthcare and government headquarters deployments require complete triple+1 power + three layered fan trays + dual supervisors + six-fabric-module hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant isolation features support mixed enterprise and agency workloads in a single large chassis.
  4. Medium-Large MPLS Service Provider Multi-Tenant PoP Edge Gateway
    Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N77-C7710 ideal for large metro PoP edge deployments, terminating large-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and L4-L7 service M3 line card upgrades.
  5. Legacy Large-Scale SAN-LAN Fabric Consolidation Migration Director
    Drop-in performance upgrade for aging Nexus 7000 series large core switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data-center OTV/LISP automation workflows.
  6. Hyperscale Centralized Enterprise Tape Library Backup Fabric Aggregation Core
    Deployed as dedicated backup SAN aggregation core director, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slots available for high-density host port expansion or M3 encryption/replication service line card additions as enterprise storage compliance requirements expand.

8. Standard Package Contents (Bare Chassis N77-C7710 Base SKU)

1 × N77-C7710 Nexus 7710 14RU empty modular switch chassis (front-to-back airflow, no factory pre-installed fans, supervisors, fabric modules, power supplies, I/O line cards)
19-inch standard 19-inch rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety & compliance documentation

Items Sold Separately (Mandatory Components Not Included in Bare Chassis)

  • Up to four N77-AC-3KW-WS 3000W AC hot-swappable redundant power supply units (DC variant N77-DC-3KW-WS for telecom deployments, 3.5kW HV HVDC N77-HV-3.5KW-WS)
  • Two redundant N77-SUP2 / N77-SUP2E fabric control modules (mandatory for full dual control-plane HA operation)
  • Up to six N77-C7710-FAB-2 / FAB-3 crossbar fabric switching modules (six FAB-3 required for full 42 Tbps chassis bandwidth)
  • Three N77-C7710-FAN / FAN-2 hot-swappable multi-fan cooling trays (minimum two required for thermal compliance)
  • Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3/F4 switching module, N77-M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
  • SFP+/QSFP+/QSFP28 optical fiber transceivers for all base Ethernet/FCoE ports (backward compatible with legacy 1G SFP transceivers)
  • Optional feature software licenses: IVR Inter-VSAN Routing, FCIP SAN Extension Enabler, Mainframe FCoE Enabler, OTV Data Center Interconnect, IOA I/O Acceleration, DMM Data Migration, MPLS XL Scale
  • RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories

Short Commercial Catalog Summary (For Quotation & Datasheet Use)

The Cisco N77-C7710 is an End-of-Sale 14RU large modular converged LAN/FCoE data center core switch bare chassis from the legacy Nexus 7700 Series 100G Generation, supplied bare without power supplies, fan trays, crossbar fabric modules, supervisor modules and pluggable Ethernet/FCoE I/O line cards (all FRUs sold separately). Built on a 42 Tbps non-blocking parallel crossbar fabric backplane with two dedicated half-slot Supervisor-2E dual redundant control slots plus eight universal hot-swappable I/O line card expansion slots supporting up to 192 total 100G QSFP28 ports (compatible with 10G SFP+ lossless FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow, up to four hot-swappable 3000W Platinum high-efficiency AC redundant power supply bays, three independent interchangeable multi-fan cooling trays and complete OIR live FRU hot-swap maintenance support. Running legacy Cisco NX-OS multilayer converged LAN/SAN operating system, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic storage fabric routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, hardware FEC forward error correction, lossless FCoE convergence, FICON mainframe compatible storage integration, OTV cross-data-center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for large virtualized multi-pod data center core SAN aggregation, multi-building enterprise campus core-edge and large MPLS service provider multi-tenant PoP deployments with complete triple+1 power + dual layered fan + dual-supervisor + six-fabric-module full redundant hardware architecture; superior to smaller N77-C7704/7706 compact pod core switches via eight I/O expansion slots, 192×100G maximum port density and mainstream front-to-back airflow design, limited by legacy maximum 100G Ethernet hardware generation, fixed I/O expansion ceiling and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS Level 3 and RoHS industrial standards.
Click:47 Entry Time:2026-07-14 【Print】 【Close