Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71416435416 |
ProductName: |
N77-C7706 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco N77-C7706 (Nexus 7706) Full Product Description
1. Short Overview
Cisco N77-C7706 is a 9RU mid-size modular converged LAN/FCoE data center core aggregation bare chassis from the Nexus 7700 next-gen 100G switch family, released 2015, End-of-Sale Oct 12, 2023, Final Hardware Support Expires Oct 31, 2028Cisco. It uses a multi-stage parallel crossbar fabric with up to six external hot-swappable Fabric-2 modules, dual half-slot redundant Supervisor-2/2E slots + four full universal I/O line card slots, front-to-back cold aisle airflow, triple independent hot-swappable fan trays, dual/triple 3kW / 3.5kW AC/DC power supplies. Max full-chassis non-blocking capacity 21 Tbps full-duplex, peak port density: 192×10G, 96×40G, 48×100G Ethernet/FCoE ports. It runs NX-OS 8.x/9.x, supports native lossless FCoE SAN-LAN convergence, VDC multi-tenant virtual switching, OTV cross-DC overlay, LISP workload mobility, MPLS/EVPN carrier transport, full OIR hot-swap FRU maintenance. Targeted for medium/large enterprise data center core, campus aggregation, medium service provider multi-tenant PoP border, unified fabric storage-LAN and cross-data-center disaster recovery deploymentsCisco.
2. Official Chassis Definition & Lifecycle
-
Bare chassis PN:N77-C7706(empty frame without supervisors, fabric modules, power supplies, I/O line cards, transceivers; bundled SKUs like N77-C7706-B23S2E ship pre-populated with core hardware)
-
EOL Timeline: EOS Oct 12, 2023; Final HW Support Oct 31, 2028
Core Hardware Differentiators vs N77-C7702 compact 2-slot chassis
-
Expanded slot scale: 4 universal full I/O line card slots (N77-C7702 only 1), peak 48×100G ports vs 12×100G on 7702Cisco
-
Independent external rear fabric subsystem: Six dedicated N77-C7706-FAB-2 fabric module slots (active-active parallel load-sharing, scalable total fabric bandwidth up to 21 Tbps); N77-C7702 uses embedded distributed fabric ASICs on I/O cards with no separate fabric modules and only 2.4 Tbps total capacity
-
Dual native half-slot supervisor slots (built-in full control-plane redundancy, supports dual Sup2/Sup2E out of box; N77-C7702 only single supervisor slot with no second native bay)Cisco
-
Triple separate hot-swappable fan trays (layered redundant cooling; N77-C7702 single integrated fan tray with limited cooling redundancy)Cisco
-
9RU rack height (N77-C7702 compact 3RU), mainstream front-to-back airflow standard for large enterprise cold/hot aisle data center racks
-
Unified Nexus 7700 Gen3 module compatibility: All F3/M3 10/40/100G I/O line cards, Sup2/Sup2E supervisors fully interchangeable across all Nexus 7700 chassis to unify spare inventory
-
Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe low-latency tunneling, full FICON zSystems storage integration without external gateway appliances
High-Availability Architecture
All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live maintenance without data plane outage. Up to three identical 3000W / 3500W Platinum AC/DC power supplies deliver N+1 redundant power operation; three independent multi-fan trays provide layered chassis cooling, single fan tray failure triggers SNMP alert without immediate traffic shutdown. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context partitions multi-tenant LAN workloads to prevent broadcast storm leakage across logical domains. NPV/NPIV edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Dual supervisor modules (Slot5 active, Slot6 standby) maintain full stateful synchronization, zero-I/O-loss automatic failover and non-disruptive ISSU firmware upgrades. Six independent crossbar fabric modules operate in parallel load-sharing mode; removing any single fabric module does not degrade overall chassis throughput capacityCisco.
Target deployment scenarios: Large virtualized multi-pod data center core SAN-LAN aggregation, multi-building enterprise campus distributed storage root, medium regional mission-critical cross-site disaster recovery SAN gateway, medium-large service provider multi-tenant PoP edge border switch, unified campus-wide SAN-LAN fabrics interoperable with N77-C7702 compact pod core switches and MDS 9000 SAN directors.
Model Suffix Breakdown
-
N77: Nexus 7700 next-gen 100G modular data center switch platform prefix
-
C7706: Bare empty 6-slot front chassis (4 I/O line card slots + 2 half-slot supervisor slots) + rear six fabric module slots
-
Bare chassis N77-C7706 has no K9 suffix; pre-bundled hardware SKUs with supervisors/power supplies carry -2K9 / -B23S2E suffix
-
Airflow fixed front-to-back cold intake (no separate E hot-aisle exhaust chassis variant)
3. Chassis Slot & Hardware Layout Definition
Front Panel 6 Horizontal Slots (9RU 19-inch rack)
-
Slots 1,2,3,4: Four universal hot-swappable I/O line/service module slots (F3/M3 10/40/100G Ethernet/FCoE switching cards, DS-X9334 FCIP multi-protocol extension modules, SSM encryption/asynchronous replication service modules)
-
N77-F348XP-23: 48×10G SFP+ high-density F3 series line card
-
N77-F324FQ-25: 24×40G QSFP+ F3 series line card
-
N77-F312CK-26: 12×100G QSFP28 F3 maximum-density line card (max 48×100G ports full chassis)
-
N77-M348XP-23L: 48×10G M3 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
-
Slots 5,6: Dedicated half-slot Supervisor-2E / Supervisor-2 fabric control module slots (dual redundant native to chassis, active/standby deployment standard)
Rear Panel Redundant Subsystems
-
Up to six independent hot-swappable N77-C7706-FAB-2 crossbar fabric switching modules (220Gbps per fabric channel, parallel load-sharing for scalable 21 Tbps total throughput)
-
Three independent hot-swappable multi-fan variable-speed fan tray bays (N77-C7706-FAN) for layered redundant cooling
-
Up to three hot-swappable power supply bays supporting AC 3kW / 3.5kW HV HVDC / DC 3kW power modules (N+1 redundant power protection)
Out-of-Band Management Interfaces (each Supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export dedicated interface)
-
External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
-
Physical reset button for factory default configuration recovery
Front Global Diagnostic LED Bank
Chassis system health status, power supply A/B/C, triple rear fan tray fault indicators, six fabric module status, dual supervisor module health, four I/O line card port link activity, hardware fault alarm, UID locator beacon LED
Airflow Specification
Fixed front-to-back airflow: Cold air intake from front panel side, hot air exhausted from rear power/fabric compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N77-C7706)
Supported Transceivers & Pluggable Modules
-
Ethernet/FCoE optical transceivers (sold separately for all line card ports):
-
SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
-
QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
-
QSFP28: 100G-SR4/LR4 for 100G high-density uplink/host ports
-
Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
-
Supervisor module compatibility: Supervisor-2 (N77-SUP2), Supervisor-2E (N77-SUP2E upgraded larger memory, enhanced FCoE telemetry NPU, Secure Boot)
-
Fabric module compatibility: N77-C7706-FAB-2 Generation2 crossbar fabric modules (six required for full 21 Tbps chassis bandwidth)
-
Power supply compatibility: 3000W AC PEM modules (N77-AC-3KW-WS), 3000W DC PEM telecom modules (N77-DC-3KW-WS), 3.5kW HV HVDC power supplies (N77-HV-3.5KW-WS), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Performance Specifications
Core Switching & Routing Performance
-
Full-chassis parallel crossbar fabric maximum aggregate bandwidth: 21 Tbps full-duplex system-wide throughput with six Fabric-2 modules fully loadedCisco
-
Wire-speed frame forwarding rate: Up to 21000 Mpps Ethernet frame switching at full 100G line rate
-
Low-latency distributed shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
-
MAC address table capacity: 128,000 MAC entries
-
IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
-
Maximum isolated VDC virtual switch contexts: 8 independent logical switch partitions + 1 admin VDC
-
Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
-
Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
-
NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload suite: FC-NVMe ultra-low-latency frame tunneling, FCoE lossless PFC/DCBX/VNTag processing, vPC peer synchronization, OTV cross-DC encapsulation, LISP endpoint mapping, FCIP tunnel compression/tape pipelining, DMM non-disruptive data migration, IOA storage I/O acceleration, onboard streaming telemetry export
Power & Cooling System
-
Power supply bays: 3 hot-swappable redundant slots, each 3000W AC PSU fully powers complete chassis independently (N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal alternating current, 80 Plus Platinum high efficiency
-
Fan trays: Three independent hot-swappable multi-fan variable-speed assemblies; minimum two full fan trays functional to avoid thermal shutdown, single fan tray failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C short-term emergency operationCisco
-
Typical full-load power draw: 420W fully populated with four 48-port 100G line cards + dual supervisors + six fabric modules + three AC power supplies under maximum traffic load
-
MTBF: 210,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 9 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 40.0 cm × 43.9 cm × 81.3 cm (9 rack units, 17.3 × 32.0 inch depth; extended depth 93.7cm with cable management guide installed)Cisco
-
Bare chassis weight (N77-C7706 empty frame only, no fans/PSUs/supervisors/fabric/line cards): 65.8 kg (145 lbs)
-
Fully loaded maximum weight (three AC PSUs + three fan trays + six fabric modules + dual supervisors + four 48-port 100G line cards): ~92 kg (203 lbs)
-
Operating ambient temperature range: 0°C to 40°C (32°F to 104°F); certified altitude up to 2000m
-
Storage temperature range: -40°C to 70°C (-40°F to 158°F)
-
Relative humidity: 8%–80% non-condensing operating; 5%–90% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, GR63 seismic Zone 4, RoHS, FIPS 140-2 Level 2 validated
Supervisor-2E (N77-SUP2E) Built-in Hardware Specs
-
Dual-core x86 enterprise CPU, 16GB DRAM, 16GB internal compact flash storage
-
Dual 1G out-of-band management Ethernet ports, RS232 serial + mini USB local dual console ports
-
External USB flash port for NX-OS image/config backup and offline diagnostics
-
Dedicated onboard NPU for real-time streaming LAN/SAN performance telemetry export
5. Full NX-OS Multilayer Feature Set Supported
Layer 2 Ethernet & Converged FCoE Storage Fabric Services
-
VDC Virtual Device Context: Logical multi-tenant switch partitioning to isolate production/test/backup LAN/SAN workloads on single physical chassis (8 user VDCs + admin VDC)
-
Standard VLAN segmentation (4094 VLANs per VDC), PVLAN private VLAN anti-spoofing isolation
-
Complete lossless FCoE protocol stack: VSAN virtual storage fabrics, hard WWN zoning + Auto-Zone automatic fabric provisioning, FC-NVMe low-latency forwarding
-
MSTP multi-instance spanning tree for Layer 2 loop prevention, vPC dual-active peer-link redundancy, SPAN/RSPAN remote traffic mirroring for multi-session performance troubleshooting
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
-
Slow drain detection and buffer credit congestion isolation hardware feature to eliminate lossless storage traffic packet loss
-
POAP Power On Auto Provisioning zero-touch automatic switch deployment for mass rack rollouts
Multilayer Routing & Cross-Data Center Interconnect Features
-
Dynamic IPv4/IPv6 routing protocols: OSPF, EIGRP, BGP
-
VRF virtual routing and forwarding multi-tenant Layer 3 isolation
-
Licensed IVR Inter-VSAN Routing feature for secure cross-storage-fabric data forwarding
-
OTV Overlay Transport Virtualization: Cross-DC Layer 2 workload mobility for disaster recovery deployments
-
LISP Locator/ID Separation Protocol: Multi-pod workload mobility and geographically distributed data center interconnection
-
Full carrier-grade MPLS service suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
-
FCIP tunnel hardware acceleration: Lossless compression, write acceleration, tape pipelining for long-distance off-site tape backup replication
-
iSCSI multi-protocol gateway processing via M3 service line cards for IP-attached server consolidation
Advanced QoS & Traffic Prioritization
-
Four hardware priority queues per Ethernet/FCoE port for tiered classification of storage I/O, virtual machine east-west traffic, management and backup streams
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication traffic
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization
Enterprise & Service Provider Security Suite
-
Port security: Static MAC locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular multi-tier administrative access control, integrated with Cisco ISE identity services engine
-
SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
-
Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 Level 2 compliance for government and financial regulated enterprise environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN/LAN Management Tools
-
Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
-
Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
6. High Availability Capabilities (Core Differentiators vs N77-C7702 Compact 2-Slot Chassis)
-
Dual redundant Supervisor-2/2E fabric control modules native to chassis with stateful failover and ISSU non-disruptive firmware upgrades (N77-C7702 only single factory supervisor slot with no second built-in bay)
-
Four universal I/O line card expansion slots vs one on N77-C7702, supporting up to 48×100G total port density
-
Six independent active-active crossbar fabric modules delivering 21 Tbps full non-blocking throughput (N77-C7702 embedded distributed fabric limited to 2.4 Tbps)
-
Three separate independent hot-swappable fan trays for layered redundant cooling (N77-C7702 single integrated fan tray with limited fault tolerance)
-
Up to three hot-swappable high-efficiency 3kW AC redundant power supplies (N+1 triple power redundancy; N77-C7702 only dual PSUs with 1+1 limited redundancy)
-
Full OIR hot-swap maintenance for all critical FRUs: fabric modules, fan trays, supervisors, line cards, power supplies without chassis power cycle
-
Front-to-back airflow design compatible with mainstream large enterprise cold aisle rack deployments (N77-C7702 uses side-to-back airflow for small pod racks)
-
Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation feature set fully consistent with all Nexus 7700 family chassis
-
9RU rack footprint for large core aggregation deployments (N77-C7702 compact 3RU for small pod top-of-row edge core)
-
Limitation: Fixed four I/O slot ceiling with no expansion beyond built-in line card bays, legacy maximum 100G Ethernet hardware generation, end-of-sale since Oct 12, 2023, hardware support expiring Oct 31, 2028.
7. Typical Deployment Scenarios
-
Large Virtualized Multi-Pod Data Center Core SAN-LAN Switch
9RU modular rack form factor deployed as campus central SAN/LAN core aggregation switch; four 48-port 100G F3 line cards populate all I/O slots for 48 total 100G ports connecting distributed building N77-C7702 pod core switches, large-scale all-flash NVMe FCoE storage arrays and massive blade server racks, dual redundant supervisors + six active fabric modules deliver zero-failover fabric reliability, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN logical fabrics.
-
Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
Multiple N77-C7706 large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, triple redundant fan trays + triple power supplies ensure stable cooling/power during hardware maintenance, built-in FCIP hardware offload provisions asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Medium-Large Regional Mission-Critical Headquarters Converged Storage/LAN Switch
Financial, healthcare and government headquarters deployments require complete triple power + dual layered fan trays + dual supervisors + six fabric module hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant logical switch partitioning supports mixed enterprise and agency workloads on a single large chassis.
-
Medium-Large MPLS Service Provider Multi-Tenant Metro PoP Edge Gateway
Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N77-C7706 ideal for large metro PoP edge deployments, terminating large-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and L4-L7 service M3 line card upgrades.
-
Legacy Large-Scale SAN-LAN Fabric Consolidation Migration Director
Drop-in performance upgrade for aging Nexus 7000 series large core switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data-center OTV/LISP automation workflows.
-
Hyperscale Centralized Enterprise Tape Library Backup Fabric Aggregation Core
Deployed as dedicated backup SAN aggregation core switch, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slots available for high-density host port expansion or SSM encryption/replication service line card additions as enterprise storage compliance requirements expand.
8. Standard Package Contents (Bare Chassis N77-C7706 Base SKU)
1 × N77-C7706 Nexus 7706 9RU empty modular switch chassis (front-to-back airflow, no factory pre-installed fans, supervisors, fabric modules, power supplies or line cards)
19-inch standard 19-inch rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety & compliance documentation
Items Sold Separately (Mandatory Components Not Included in Bare Chassis)
-
Up to three N77-AC-3KW-WS 3000W AC hot-swappable redundant power supply units (DC variant N77-DC-3KW-WS for telecom deployments)
-
Two redundant N77-SUP2 / N77-SUP2E fabric control modules (mandatory for full dual control-plane HA operation)
-
Up to six N77-C7706-FAB-2 crossbar fabric switching modules (six required for full 21 Tbps chassis bandwidth)
-
Three N77-C7706-FAN hot-swappable multi-fan cooling trays (minimum two required for thermal compliance)
-
Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3 switching module, N77-M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
-
SFP+/QSFP+/QSFP28 optical fiber transceivers for all base Ethernet/FCoE port interfaces (backward compatible with legacy 1G SFP transceivers)
-
Optional feature software licenses: IVR Inter-VSAN Routing, FCIP SAN Extension Enabler, Mainframe FCoE Enabler, OTV Data Center Interconnect, IOA I/O Acceleration, DMM Data Migration, MPLS XL Scale
-
RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories
Short Commercial Catalog Summary for Quotation
The Cisco N77-C7706 is an End-of-Sale 9RU mid-large modular converged LAN/FCoE data center core switch bare chassis from the legacy Nexus 7700 Series 100G Generation, supplied empty without power supplies, fan trays, crossbar fabric modules, supervisor modules and pluggable Ethernet/FCoE I/O line cards (all FRUs sold separately). Built on a 21 Tbps non-blocking parallel crossbar fabric backplane with two dedicated half-slot Supervisor-2/2E redundant control slots plus four universal hot-swappable I/O line card expansion slots supporting up to 48 total 100G QSFP28 ports (compatible with 10G SFP+ lossless FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow, up to three hot-swappable 3000W Platinum high-efficiency AC redundant power supply bays, three independent interchangeable multi-fan cooling trays and complete OIR live FRU hot-swap maintenance support. Running legacy Cisco NX-OS multilayer converged LAN/SAN operating system, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic storage fabric routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, hardware FEC forward error correction, lossless FCoE convergence, FICON mainframe compatible storage integration, OTV cross-data-center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for large virtualized multi-pod data center core aggregation, medium enterprise campus edge and medium MPLS service provider multi-tenant PoP storage/LAN deployments with complete triple power + dual layered fan + dual-supervisor + six-fabric-module full redundant hardware architecture; superior to smaller N77-C7702 compact pod core switches via four I/O expansion slots, 48×100G maximum port density and mainstream front-to-back airflow design, limited by legacy maximum 100G Ethernet hardware generation, fixed I/O expansion ceiling and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS Level 3 and RoHS industrial standards.
|
|
|
| Click:15 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|