 Product >> Cisco >> ALL
 
Product_Id:
71416294516
ProductName:
C1-N7702
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco C1-N7702 Full Product Description

1. Short Overview

C1-N7702is the Cisco ONE commercial bare chassis SKU for the Nexus 7702 3RU compact modular converged LAN/FCoE data center core switch, identical physical hardware to the base bare chassis PN N77-C7702. It includes the integrated factory fan tray, no power supplies, supervisors, I/O line cards or software licenses included. It runs NX-OS 8.x/9.x, delivers a distributed embedded fabric with 2.4 Tbps full-duplex non-blocking throughput, front-to-back cold aisle airflow, supports 10/40/100G F3/M3 I/O modules, native lossless FCoE SAN-LAN convergence, VDC multi-tenant virtualization, OTV cross-DC overlay, LISP workload mobility and full OIR hot-swap maintenance. End-of-Sale Oct 12, 2023; Final Hardware Support End Date Oct 31, 2028.
image
Cisco Nexus 7702 Chassis

2. Key Definition & Suffix Explanation

  1. C1 prefix: Cisco ONE commercial channel SKU series (standard reseller/enterprise bundled chassis PID, same physical hardware as technical bare chassis N77-C7702)Cisco
  2. N77: Nexus 7700 next-gen 100G modular data center switch platform
  3. 7702: 2-slot compact chassis (1 full I/O line card slot + 1 half-slot supervisor slot)
  4. Core difference between C1-N7702 and N77-C7702: Only ordering channel PID difference; all hardware, slot layout, performance, airflow, module compatibility are 100% identical.
  5. What C1-N7702 contains factory-integrated:
    • N77-C7702 3RU passive midplane empty chassis
    • Built-in single hot-swappable multi-fan tray (pre-installed, no separate fan purchase needed)
    • Standard 19-inch rack mounting rails, cable management brackets, hardware documentation
  6. ItemsNOT included (must order separately):
    • Dual 3000W AC/DC power supplies (N77-AC-3KW-WS / N77-DC-3KW-WS)
    • Supervisor 2E / Supervisor 3E control modules (N77-SUP2E / N77-SUP3E)
    • F3/M3 series I/O line/service modules for the single I/O slot
    • SFP+/QSFP+/QSFP28 optical transceivers
    • Add-on feature licenses (IVR, OTV, FCIP, FICON, MPLS XL scale, DMM, IOA)
    • Locked front door, air filter, extended cable management accessories

3. Chassis Hardware Architecture & Slot Layout

Front Panel 2 Horizontal Slots (3RU standard 19-inch rack)

  1. Slot 1: One full universal hot-swappable I/O line card slot (only one I/O module supported at maximum):
    • N77-F348XP-23: 48×10G SFP+
    • N77-F324FQ-25: 24×40G QSFP+
    • N77-F312CK-26: 12×100G QSFP28 (max 12×100G ports total chassis)
    • N77-M348XP-23L: M3 multi-protocol service card with L4-L7 offload, FCIP/iSCSI gateway capability
  2. Slot 2: Dedicated half-size supervisor slot (supports single Sup2E/Sup3E; chassis has no second supervisor slot for native dual control-plane redundancy)

Rear Redundant Subsystems

  • Two empty hot-swappable power supply bays (1+1 redundant power, PSUs sold separately)
  • No external rear crossbar fabric modules: Distributed fabric ASICs embedded inside supervisor and I/O line cards, eliminating separate fabric module maintenance and spare inventory cost

Airflow Specification

Fixed front-to-back cold air intake (cold air flows from front panel, hot air exhausted from rear power compartment; no reverse hot-aisle exhaust chassis variant)

Management Interfaces (per Supervisor module)

  • RJ45 RS232 serial console port for local CLI access
  • Mini USB dual local console port for zero-cable laptop administration
  • Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (dedicated port for SAN telemetry streaming export)
  • External USB Type-A flash storage slot for NX-OS firmware upgrades, running configuration backup and syslog export
  • Physical reset button for factory default configuration recovery

Front Panel LED Status Indicators

System health, power supply A/B status, integrated fan tray fault, supervisor module status, I/O line card port link activity, global fault alarm, UID locator beacon LED

4. Hardware Performance Specifications

  1. Full non-blocking distributed fabric aggregate bandwidth: 2.4 Tbps full-duplex system-wide throughput
  2. Wire-speed forwarding rate: Up to 2400 Mpps Ethernet frame switching at maximum 100G line rate
  3. Layer 2 MAC address table capacity: 128,000 MAC entries
  4. Layer 3 route scale: IPv4 unicast 128,000 entries; IPv6 unicast 64,000 entries; multicast routes 32,000 entries
  5. Maximum VDC virtual multi-tenant logical switch partitions: 4 independent isolated VDCs
  6. Port-channel limit: 1024 logical trunk bundles, maximum 16 physical ports per PortChannel for vPC/ISL links
  7. Native hardware ASIC offload feature set:
    • Lossless FCoE storage convergence: PFC priority flow control, DCBX, VNTag, FC-NVMe low-latency tunneling
    • DMM non-disruptive data migration, IOA storage I/O acceleration
    • OTV cross-data-center overlay encapsulation, LISP endpoint mapping
    • FCIP tunnel compression, write acceleration and tape pipelining for long-distance DR backup replication

Physical & Environmental Parameters

  • Rack height: 3 RU (13.08 cm tall), standard 19-inch EIA horizontal rack mount
  • External dimensions (H × W × D): 13.08 cm × 43.9 cm × 73.9 cm; extended depth 89.15 cm with cable management kit installed
  • Bare chassis weight (C1-N7702 only, fan tray included, no PSUs/supervisors/line cards): ~17 kg (37.5 lbs)
  • Fully loaded maximum weight (dual AC PSUs + 1×Sup2E + 1×48-port 100G I/O line card): ~26 kg (57 lbs)
  • Operating ambient temperature: 0°C ~ 40°C (32°F ~ 104°F); certified altitude up to 2000m
  • Storage temperature: -40°C ~ 70°C (-40°F ~ 158°F)
  • Relative humidity: 10%–90% non-condensing operating
  • Compliance certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS, FIPS 140-2 Level 2 validated

Supervisor 2E (N77-SUP2E) Key Specs (compatible with C1-N7702)

  • Dual-core x86 enterprise CPU, 16GB DRAM, 16GB internal compact flash storage
  • Dual 1G out-of-band management Ethernet ports, serial + mini USB local console
  • Dedicated onboard NPU for real-time streaming LAN/SAN performance telemetry export

5. Full NX-OS Feature Set Supported

Layer 2 Ethernet & Converged FCoE Storage Fabric

  • VDC Virtual Device Context: Logical multi-tenant isolation to separate production/test/backup LAN/SAN workloads
  • 4094 VLANs per VDC, PVLAN private VLAN anti-spoofing isolation
  • Complete lossless FCoE protocol stack: VSAN virtual storage fabrics, hard WWN zoning, Auto-Zone automatic fabric provisioning, FC-NVMe low-latency forwarding
  • MSTP multi-instance spanning tree for Layer 2 loop prevention, vPC dual-active peer-link redundancy
  • SPAN / RSPAN remote traffic mirroring for multi-session performance troubleshooting
  • NPV/NPIV FCoE edge virtualization to offload Fibre Channel host registration and reduce upstream MDS SAN fabric control-plane overhead
  • Slow drain detection and buffer credit congestion isolation for lossless storage traffic
  • POAP Power On Auto Provisioning zero-touch automatic switch deployment for mass rack rollouts

Multilayer Routing & Cross-Data Center Interconnect Features

  • Dynamic IPv4/IPv6 routing protocols: OSPF, EIGRP, BGP
  • VRF virtual routing and forwarding for multi-tenant Layer 3 isolation
  • Licensed IVR Inter-VSAN Routing for cross-storage-fabric data forwarding
  • OTV Overlay Transport Virtualization: Layer 2 workload mobility across geographically separated disaster recovery data centers
  • LISP Locator/ID Separation Protocol: Multi-pod workload mobility and DC interconnection
  • Full carrier-grade MPLS suite: LDP, VPLS, VPWS, EVPN-FC dual-stack IPv4/IPv6 multi-tenant transport
  • FCIP tunnel hardware acceleration: Lossless compression, write acceleration, tape pipelining for long-distance off-site tape backup replication
  • M3 service line card support for iSCSI multi-protocol gateway and L4-L7 traffic offload

QoS, Security & Automation

  • Four hardware priority queues per Ethernet/FCoE port for tiered classification of storage I/O, VM east-west traffic, management and backup streams
  • Ingress policing + egress bandwidth shaping to throttle low-priority backup/replication traffic
  • RBAC granular multi-tier administrative access control, Cisco ISE identity services engine integration
  • SSHv2 encrypted remote management, SNMPv3 secure monitoring, AES encrypted startup configurations, DH-CHAP FCoE inter-fabric link authentication
  • FIPS 140-2 Level 2 compliance for financial, government and regulated enterprise deployments
  • Cisco DCNM centralized graphical converged LAN/SAN fabric management, REST API automation
  • Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
  • GOLD Generic Online Diagnostics continuous hardware health validation without production traffic interruption

6. High Availability Architecture & Differentiators vs Larger Nexus 7706/7710

  1. Compact 3RU rack footprint optimized for small virtualized pod top-of-row core aggregation (N7706=9RU, N7710=14RU)
  2. Distributed embedded fabric ASICs inside supervisors/I/O line cards — no external rear crossbar modules required, reducing spare part inventory and maintenance steps
  3. Single integrated multi-fan tray with multi-fan fault tolerance; single fan failure triggers SNMP alert without immediate traffic outage
  4. Dual hot-swappable 3000W AC/DC power supplies (1+1 N+1 redundant power protection)
  5. Only one universal I/O line card expansion slot ceiling (max 1×48-port 100G module), limited total port density compared to multi-slot larger chassis
  6. Single native supervisor slot; full dual-chassis HA failover requires pairing a second C1-N7702-S2E-AC as vPC peer switch
  7. Fixed front-to-back cold aisle airflow design compatible with mainstream enterprise data center rack layouts
  8. Unified NX-OS feature parity with all Nexus 7700 family: EVPN, OTV, LISP, VDC, FCoE and REST API automation feature set fully consistent across chassis models
  9. End-of-Sale status Oct 12, 2023; hardware support expires Oct 31, 2028, legacy maximum 100G Ethernet hardware generation with no native 400G port support

7. Typical Deployment Scenarios

  1. Small virtualized data center pod core aggregation: Deployed as pod top-of-row core switch, single 100G F3 line card delivers 12×100G uplinks to leaf Nexus 2000 FEX extenders and small-scale all-flash NVMe FCoE storage arrays, VDC + VSAN segmentation isolates independent production/test/backup converged LAN/SAN logical fabrics.
  2. Medium multi-building enterprise campus edge converged switch: Interconnects remote building access switches via OTV cross-DC overlay tunnels, built-in FCIP hardware offload provides asynchronous disaster recovery replication between primary and secondary backup data centers.
  3. Small-to-medium service provider multi-tenant metro PoP edge gateway: VDC multi-tenant logical switch partitioning separates independent enterprise customer LAN/SAN fabrics on a single physical chassis, unused I/O slot reserved for future port count expansion or M3 L4-L7 service line card upgrades.
  4. Financial/mainframe zSystems converged storage core: Native FCoE + FICON compatibility enables long-distance FCIP tape backup replication, dual AC power redundancy paired with a second C1-N7702-S2E-AC peer switch for full site-wide HA fault tolerance.
  5. Legacy Nexus 5000 FCoE fixed switch migration upgrade: Backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS OTV/LISP cross-data-center automation workflows.
  6. Centralized small enterprise tape library backup fabric aggregation core: Dedicated backup fabric switch using multi-port FCIP PortChannel trunks to primary production FCoE SAN fabrics for asynchronous off-site tape archive replication, unused I/O slot available for high-density host port expansion or encryption/replication SSM service module additions.

8. Standard Package Contents of C1-N7702 Bare Chassis SKU

1 × C1-N7702 Nexus 7702 3RU empty modular switch chassis (front-to-back airflow, integrated multi-fan tray factory pre-installed)
19-inch standard 19-inch rack mounting rails, front cable management brackets
Cisco hardware installation guide, global safety & compliance documentation

Separately Mandatory Components (Not Included in C1-N7702 Bare Chassis)

  • Dual N77-AC-3KW-WS 3000W AC hot-swappable redundant power supplies (DC variant N77-DC-3KW-WS for telecom deployments)
  • One N77-SUP2E / N77-SUP3E supervisor control module (mandatory for chassis operation)
  • Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3 switching module, M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
  • SFP+/QSFP+/QSFP28 optical fiber transceivers for all Ethernet/FCoE port interfaces (backward compatible with legacy 1G SFP transceivers)
  • Optional feature software licenses: IVR Inter-VSAN Routing, FCIP SAN Extension Enabler, Mainframe FCoE Enabler, OTV Data Center Interconnect, IOA I/O Acceleration, DMM Data Migration
  • RS232 serial console rollover cable, mini USB console cable, fiber/copper patch cords, rack cable management accessories, locking front door, air filter kit

Short Commercial Catalog Summary for Quotation

The Cisco C1-N7702 is an End-of-Sale 3RU compact modular converged LAN/FCoE data center core switch bare chassis (Cisco ONE commercial channel SKU, identical hardware to N77-C7702), supplied without power supplies, supervisor modules and pluggable Ethernet/FCoE I/O line cards, with integrated factory multi-fan cooling tray. Built on a 2.4 Tbps non-blocking distributed embedded fabric passive midplane backplane with one dedicated half-slot Supervisor-2E/3E control slot plus one universal hot-swappable I/O line card expansion slot supporting up to 12 total 100G QSFP28 ports (compatible with 10G SFP+ lossless FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow, dual hot-swappable 3000W Platinum high-efficiency AC redundant power supply bays and complete OIR live FRU hot-swap maintenance support. Running legacy Cisco NX-OS multilayer converged LAN/SAN operating system, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic storage fabric routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, hardware FEC forward error correction, lossless FCoE convergence, FICON mainframe compatible storage integration, OTV cross-data-center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for small virtualized data center pod core aggregation, medium enterprise campus edge and small MPLS service provider multi-tenant PoP storage/LAN deployments with complete dual power + single-fan + single-supervisor hardware redundancy architecture; unique among Nexus 7700 chassis via compact 3RU rack footprint and embedded distributed fabric without external crossbar modules, limited by only one I/O expansion slot ceiling, legacy maximum 100G Ethernet hardware generation and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS and RoHS industrial standards.