|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71416233816 |
ProductName: |
N77-C7702 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco N77-C7702 (Nexus 7702) Full Product Description
Cisco N77-C7702 Front View
1. Short Overview
Cisco N77-C7702 is a compact 3RU 2-slot modular next-gen data center core/convergence bare chassis from the Cisco Nexus 7700 series, released Jan 12, 2015, End-of-Sale Oct 12, 2023, Final End-of-Support Date Oct 31, 2028Cisco. It uses a passive midplane embedded distributed fabric architecture (no separate rear crossbar modules), supports 1× half-slot Supervisor-2E/Supervisor-3E + 1× full-size F3/M3 I/O line card slot, dual 3000W power supply bays, integrated single hot-swappable fan tray, front-to-back cold aisle airflow, maximum 1.32 Tbps full-duplex non-blocking throughput, up to 48×10G / 24×40G / 12×100G Ethernet/FCoE ports. It runs modern NX-OS 8.x/9.x, delivers native lossless FCoE SAN-LAN convergence, VDC multi-tenant virtualization, OTV cross-DC overlay, LISP workload mobility, MPLS multi-tenant transport, full OIR hot-swap FRU maintenance, targeted for small data center pod core aggregation, medium enterprise campus edge, small service provider PoP and mid-size converged LAN/FCoE storage workloads.
2. Official Lifecycle & Chassis Definition
-
Bare chassis PN:N77-C7702(empty frame with integrated fan tray; supervisors, power supplies, I/O line cards, transceivers sold separately)
-
Bundled variants: N77-C7702-S2E-AC (1×Sup2E + dual AC power preloaded)
-
EOL Timeline: EOS Oct 12, 2023; Final Hardware Support Oct 31, 2028
Core Hardware Differentiators vs Larger Nexus 7706 / 7710 / 7718
-
Ultra-compact 3RU rack height (7706=9RU, 7710=14RU, 7718=26RU), only two front slots total:1 dedicated half-slot supervisor slot + 1 full universal I/O line card slot(max one I/O module loaded, peak 48×100G ports).
-
No external rear crossbar fabric modules: Distributed fabric ASICs embedded inside I/O line card and supervisor, simplified chassis maintenance, reduces spare inventory (large 7700 chassis use 6 independent rear crossbar modules).
-
Single integrated hot-swappable fan tray (large 7706/7710 use triple dual fan trays for layered cooling).
-
Dual 3000W Platinum power supply slots (1+1 N+1 redundancy; 7710 supports up to eight PSUs for octal redundancy).
-
Front-to-back standard cold aisle airflow (no hot-aisle reverse airflow variant).
-
Unified Nexus 7700 Gen3 module compatibility: F3/M3 10/40/100G I/O line cards, Sup2E/Sup3E supervisors fully interchangeable with larger Nexus 7700 chassis to cut spare inventory cost.
-
Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe low-latency tunneling, full FICON mainframe storage integration without external gateways.
-
Full OIR hot-swap for all FRUs: supervisor, I/O line card, power supplies, fan tray without chassis power cycle for zero service interruption.
Core High-Availability Design
All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live maintenance without data plane outage. Dual identical 3000W Platinum AC power supplies deliver 1+1 redundant power operation; single integrated multi-fan tray provides full chassis cooling, single fan failure triggers SNMP alert without immediate shutdown. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context partitions multi-tenant LAN workloads to prevent broadcast leakage across logical domains. NPV/NPIV edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Single supervisor factory baseline; customer can deploy redundant high-availability via chassis stacking or dual separate N77-C7702 peer switches for stateful failover and non-disruptive ISSU firmware upgrades.
Target deployment scenarios: Small virtualized data center pod core SAN-LAN aggregation, small multi-building enterprise campus distributed storage root, medium regional mid-size cross-site disaster recovery SAN gateway, small-to-medium service provider multi-tenant PoP edge switch, unified compact pod-level converged LAN/SAN fabrics interoperable with N77-C7706 mid-size modular directors and MDS 9000 SAN directors.
Model Suffix Breakdown
-
N77: Nexus 7700 next-gen 100G modular data center switch platform prefix
-
C7702: Bare empty 2-slot front chassis (1 full I/O line card slot + 1 half-slot supervisor slot)
-
K9: Standard AC power SKU with full NX-OS enterprise/carrier feature license (base bare chassis N77-C7702 has no K9 suffix)
-
Airflow fixed front-to-back cold intake (no separate E hot-aisle exhaust chassis variant)
3. Chassis Slot & Hardware Layout Definition
Front Panel 2 Horizontal Slots (3RU 19-inch rack)
-
Slot 1: One full universal hot-swappable I/O line/service module slot (F3/M3 10/40/100G Ethernet/FCoE switching cards, DS-X9334 FCIP multi-protocol extension modules, SSM encryption/asynchronous replication service modules)
-
Slot 2: Dedicated half-slot Supervisor-2E / Supervisor-3E fabric control module slot (only one supervisor slot built into chassis, no second redundant supervisor bays on N77-C7702)
Rear Panel Redundant Subsystems
-
Two independent hot-swappable 3000W power supply bays supporting AC or DC high-voltage power modules
-
Single integrated hot-swappable multi-fan variable-speed fan tray embedded into bare chassis (included with N77-C7702 base chassis)
Out-of-Band Management Interfaces (each Supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export dedicated interface)
-
External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
-
Physical reset button for factory default configuration recovery
Front Global Diagnostic LED Bank
Chassis system status, power supply A/B, integrated fan tray, supervisor module, I/O line card port link activity, hardware fault alarm, UID blue locator beacon indicator
Airflow Specification
Fixed front-to-back airflow: Cold air intake from front panel side, hot air exhausted from rear power compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N77-C7702)
Supported Transceivers & Pluggable Modules
-
Ethernet/FCoE optical transceivers (sold separately for all line card ports):
-
SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
-
QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
-
QSFP28: 100G-SR4/LR4 for 100G high-density uplink/host ports
-
Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
-
Supported pluggable I/O line/service modules for Slot 1:
-
N77-F348XP-23: 48×10G SFP+ high-density F3 series line card (max 48×10G ports full chassis)
-
N77-F324FQ-25: 24×40G QSFP+ F3 series line card (max 24×40G ports full chassis)
-
N77-F312CK-26: 12×100G QSFP28 F3 maximum-density line card (max 12×100G ports full chassis)
-
N77-M348XP-23L: 48×10G M3 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
-
SSM Storage Services Module: Inline tape/media encryption, asynchronous cross-fabric replication, SAN performance analytics
-
Supervisor module compatibility: Supervisor-2E (N77-SUP2E), Supervisor-3E (N77-SUP3E upgraded larger memory, enhanced FCoE telemetry NPU, Secure Boot)
-
Power supply compatibility: 3000W Platinum AC PEM modules (N77-AC-3KW-WS), 3000W DC PEM telecom modules (N77-DC-3KW-WS), 3.5kW HV HVDC power supplies (N77-HV-3.5KW-WS), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Performance Specifications
Core Switching & Routing Performance
-
Single-chassis distributed fabric maximum aggregate bandwidth: 1.32 Tbps full-duplex system-wide bandwidth
-
Wire-speed frame forwarding rate: Up to 1320 Mpps Ethernet frame switching at full 100G line rate
-
Low-latency shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
-
MAC address table capacity: 128,000 MAC entries
-
IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
-
Maximum isolated VDC virtual switch contexts: 4 independent logical switch partitions
-
Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
-
Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
-
NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload: FC-NVMe ultra-low-latency frame processing, FCoE lossless frame processing, FCoE PFC/DCBX/VNTag, FCIP write acceleration, tape pipelining, FCIP compression, DMM non-disruptive data migration, IOA I/O acceleration, onboard NPU real-time SAN telemetry streaming
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 3000W AC PSU fully powers complete chassis independently (1+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current, 80 Plus Platinum high efficiency
-
Fan tray: Integrated multi-fan variable-speed assembly built into bare chassis; minimum full tray functional to avoid thermal shutdown, single fan failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
-
Typical full-load power draw: 160W fully populated with one 48-port 100G line card + single supervisor module under maximum traffic load
-
MTBF: 240,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 3 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 13.08 cm × 44.45 cm × 73.9 cm (3 rack units, 17.5 × 29.1 inch depth; extended depth 86.3cm with cable management guide installed)
-
Bare chassis weight: 17 kg (37.5 lbs) without power supplies/line cards/supervisors; fully loaded maximum weight 26 kg (57 lbs) with dual PSUs, single fan tray, one 48-port 100G line card and one supervisor module installedCisco
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations, FIPS 140-2 Level 2 validated
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access per supervisor: RJ45 RS232 serial port + Mini USB console port
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports
-
External USB flash storage for offline NX-OS firmware and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full NX-OS Multilayer Feature Set (Cisco NX-OS MDS Release 8.x / 9.x Universal Image)
Layer 2 Ethernet & Converged FCoE Fabric Services
-
VDC Virtual Device Context: Logical virtual switch partitioning to isolate multi-tenant LAN/SAN workloads on single physical chassis
-
Standard VLAN segmentation (4094 VLANs per VDC), PVLAN private VLAN isolation
-
Dual zoning models for FCoE: VSAN virtual storage fabric segmentation, hard WWN zoning + Autozone automatic fabric zoning
-
Complete FCoE protocol stack support: Lossless PFC priority flow control, DCBX, VNTag virtual machine storage I/O tracking, FC-NVMe tunneling
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 10G/40G/100G Ethernet port speeds (max 16-port bundles)
-
DTP dynamic trunk negotiation, MSTP multi-instance spanning tree protocol for Layer 2 loop prevention
-
Local SPAN, RSPAN remote traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation for lossless FCoE traffic
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass pod rack rollouts
Multilayer Routing & Multi-Protocol Data Center Interconnect Features
-
FSPF Fibre Channel Shortest Path First dynamic SAN fabric routing for distributed storage topologies
-
EIGRP / OSPF / BGP IPv4/IPv6 dynamic Layer 3 routing protocols for LAN workloads
-
PIM-SM / PIM-SSM IP multicast for cross-fabric asynchronous backup replication traffic
-
Static IP route configuration, VRF virtual routing and forwarding multi-tenant routing isolation
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated FCoE storage fabrics
-
Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
-
OTV Overlay Transport Virtualization cross-data center layer 2 overlay for disaster recovery workload mobility
-
LISP Locator/ID Separation Protocol for multi-pod workload mobility and DC interconnection
-
FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance cross-site disaster recovery replication
-
iSCSI multi-protocol gateway processing via DS-X9334 service modules for IP-attached server consolidation
Advanced QoS & Traffic Prioritization
-
Four hardware priority queues per Ethernet / FCoE port for tiered classification of storage I/O, virtual machine data, management and backup traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization
Enterprise & Service Provider Security Suite
-
Port security: Static MAC locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE identity services engine
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for FCoE ISL inter-switch link fabric authentication
-
Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 validated security compliance for government and financial regulated environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN/LAN Management Tools
-
Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
-
Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
6. High Availability Capabilities (Core Differentiators vs N77-C7706 Mid-Size 6-Slot Director)
-
Dual hot-swappable high-efficiency 3000W AC redundant power supplies (1+1 redundant architecture; N77-C7706 supports up to four PSUs with expanded power capacity)
-
Single integrated multi-fan tray with multi-fan fault tolerance (survive single fan tray failure without SAN outage; N77-C7706 uses three layered independent fan trays for higher cooling redundancy)
-
Embedded distributed fabric ASICs inside supervisor/I/O line cards delivering 1.32 Tbps full non-blocking bandwidth (N77-C7706 uses six external crossbar modules reaching 12.3 Tbps total throughput, far larger scale)
-
Single half-slot Supervisor-2E/3E control module (no second built-in supervisor slot; N77-C7706 dual redundant supervisor slots native to chassis)
-
Only one universal I/O line card expansion slot vs four on N77-C7706, limited maximum port density (12×100G vs 48×100G on 7706)
-
Full OIR hot-swap support for all critical FRUs: fan tray, power supplies, supervisor, single I/O line card without chassis power cycle
-
Front-to-back airflow design optimized for mainstream cold aisle rack deployments (shared airflow standard with all Nexus 7700 chassis)
-
Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation features consistent with all Nexus 7700 family
-
Compact 3RU rack footprint ideal for small pod top-of-row core aggregation (N77-C7706 is 9RU, triple rack height for larger core deployments)
-
Limitation: Fixed single I/O slot ceiling with no expansion beyond one built-in line card bay, legacy maximum 100G Ethernet hardware generation, end-of-sale since Oct 12, 2023, hardware support expiring Oct 31, 2028.
7. Typical Deployment Scenarios
-
Small Virtualized Data Center Pod Core Switch
Compact 3RU rack form factor deployed as pod top-of-row core aggregation switch; single 48-port 100G F3 line card populates the only I/O slot for 12 total 100G ports connecting distributed rack Nexus 2000 FEX leaf extenders, small-scale all-flash NVMe FCoE storage arrays and low-density blade server racks, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN fabrics.
-
Medium Multi-Building Enterprise Campus Edge SAN-LAN Fabric
Multiple N77-C7702 compact pod core switches deployed per building data center rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, built-in FCIP hardware offload provision asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Medium Regional Mission-Critical Headquarters Converged Storage/LAN Switch
Financial, healthcare and government headquarters deployments require complete dual power + single integrated fan tray + single supervisor hardware redundancy, paired with a second N77-C7702 peer switch for dual-chassis HA to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant isolation features support mixed enterprise and agency workloads in a single compact chassis.
-
Small-to-Medium Service Provider Multi-Tenant PoP Edge Switch
Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N77-C7702 ideal for compact metro PoP edge deployments, terminating small-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slot reserved for future growth in customer port count and L4-L7 service M3 line card additions.
-
Legacy Small-Scale SAN-LAN Hardware Consolidation Migration Switch
Drop-in performance upgrade for aging Nexus 5000 fixed FCoE switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G/100G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data center OTV/LISP automation workflows.
-
Centralized Small Enterprise Tape Library Backup Fabric Aggregation Core
Deployed as dedicated backup SAN aggregation core switch, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slot available for high-density host port expansion or M3 encryption/replication service line card additions as enterprise storage compliance requirements expand.
8. Standard Package Contents (Bare Chassis N77-C7702 Base SKU)
1 × N77-C7702 Nexus 7702 3RU empty modular switch chassis (front-to-back airflow, integrated multi-fan tray pre-installed)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety & compliance documentation
Items Sold Separately (Not Included in Bare Chassis N77-C7702)
-
Dual 3000W Platinum AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
-
One redundant Supervisor-2E or Supervisor-3E fabric control module (mandatory for chassis operation)
-
Optional Nexus 7700 family pluggable I/O line/service modules (48-port 10/40/100G F3 switching module, N77-M3 multi-protocol FCIP/iSCSI L4-L7 service module, SSM storage encryption/replication module)
-
SFP+/QSFP/QSFP28 optical fiber transceivers for all line card Ethernet/FCoE interfaces (backward compatible with legacy 1G SFP transceivers)
-
Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FCoE Enabler license, OTV Data Center Interconnect license
-
RS232 serial console rollover cable, mini USB console cable
-
USB flash memory sticks for NX-OS image and configuration storage
-
Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Summary (For Quotation & Datasheet Use)
The Cisco N77-C7702 is an End-of-Sale 3RU compact modular converged LAN/FCoE data center core switch from the Nexus 7700 Series 100G Generation, supplied bare without power supplies, supervisor modules and pluggable Ethernet/FCoE I/O line cards (all FRUs sold separately). Built on a 1.32 Tbps non-blocking distributed embedded fabric passive midplane backplane with one dedicated half-slot Supervisor-2E/3E slot plus one universal hot-swappable I/O line card expansion slot supporting up to 12 total 100G QSFP28 ports (compatible with 10G SFP+ FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow with integrated single multi-fan cooling tray, dual hot-swappable 3000W Platinum high-efficiency AC redundant power supply bays and full OIR live FRU replacement support. Running modern Cisco NX-OS multilayer converged LAN/SAN software, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, lossless FCoE convergence, FICON mainframe compatible storage convergence, OTV cross-data center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP write/tape replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for small virtualized data center pod core aggregation, small enterprise campus edge and small service provider multi-tenant PoP deployments with complete dual power + single-fan + single-supervisor hardware redundancy architecture; unique among Nexus 7700 chassis via compact 3RU rack footprint and embedded distributed fabric without external crossbar modules, limited by only one I/O expansion slot ceiling, legacy maximum 100G Ethernet hardware generation and end-of-sale status with hardware support expiring Oct 31, 2028. Compliant with global safety, EMI, NEBS and RoHS industrial standards.
|
|
|
| Click:12 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|