Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71416171716 |
ProductName: |
N7K-C7010 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco Nexus 7010 (N7K-C7010) Full Product Description
1. Short Overview
Cisco N7K-C7010 is a 21RU mid-to-large modular converged LAN/FCoE data center core switch bare chassis from the Cisco Nexus 7000 series, released 2011, End-of-Sale Feb 28, 2022, Final Hardware Support Expires Feb 28, 2027Cisco. It features a 10-slot front midplane, up to 5 rear hot-swappable Fabric-2 crossbar modules, dual redundant Supervisor-2/2E slots + 8 universal I/O line card slots, front-to-back cold aisle airflow, up to 3×6000W AC/DC redundant power supplies, dual independent hot-swappable fan trays (system fan tray + dedicated fabric fan tray), maximum 384×40G Ethernet/FCoE ports, total 4.1 Tbps full-duplex distributed fabric bandwidthCisco. It runs legacy NX-OS 6.x, natively supports lossless FCoE SAN-LAN convergence, VDC virtual multi-tenant partitioning, OTV cross-DC overlay, LISP workload mobility, MPLS multi-tenant transport, full OIR hot-swap FRU maintenance. Targeted for large enterprise multi-pod core aggregation, medium-to-large service provider multi-tenant PoP core, centralized tape backup fabric and cross-site disaster recovery workloads.
N7K-C7010 Front & Rear Layout
2. Official Product Lifecycle & Chassis Definition
-
Bare chassis PN:N7K-C7010(empty frame without supervisors, fabric modules, power supplies, line cards; bundled SKUs like N7K-C7010-2K9 include dual Sup2 + dual AC power + enterprise feature license)
-
EOL Timeline: EOS Feb 28, 2022; Last HW Support End Date Feb 28, 2027Cisco
Core Hardware Differentiators vs N7K-C7004 / N7K-C7009
-
Slot scale comparison: 8 universal I/O line card slots (N7K-C7004 only 2, N7K-C7009 only 7), peak 384×40G ports (8×48-port F2E line cards), higher port density than 7009’s 336-port ceiling.
-
Distinct front-to-back airflow (cold intake front, hot exhaust rear power compartment); N7K-C7004 uses side-to-back, N7K-C7009 uses side-to-side airflow, ideal for standard cold-aisle front-intake data center rack layoutsCisco.
-
Dual independent rear fan subsystems: Separate system fan tray for I/O/supervisor cooling + dedicated fabric fan tray for crossbar modules (N7K-C7009 only single integrated front fan tray without dedicated fabric cooling).
-
Up to five N7K-C7010-FAB-2 external active-active load-sharing fabric modules delivering 4.1 Tbps full-duplex throughput (N7K-C7004 embedded fabric only 1.92 Tbps; N7K-C7009 reaches 8.8 Tbps but uses side-to-side airflow)Cisco.
-
Up to three hot-swappable 6000W power supplies (2+1 N+1 power redundancy; N7K-C7004/7009 only dual PSUs with 1+1 redundancy limit).
-
Unified Nexus 7000 Gen2 module compatibility: All F2/F2E/M2 I/O line cards, Sup2/Sup2E supervisors interchangeable with N7K-C7004/7009 to reduce spare inventory cost.
-
Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe tunneling, full FICON mainframe storage integration without external gateway appliances.
-
Full OIR hot-swap for all FRUs: fabric modules, supervisors, line cards, power supplies, fan trays without chassis power cycle for zero service interruption.
Core High-Availability Design
All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live maintenance without data plane outage. Up to three identical 6000W Platinum AC power supplies deliver N+1 redundant power operation; dual separate hot-swappable fan trays eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context partitions multi-tenant LAN workloads to prevent broadcast leakage across logical domains. NPV/NPIV edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Dual supervisor modules (Slot5 active, Slot6 standby) maintain full stateful synchronization, zero-I/O-loss automatic failover and non-disruptive ISSU firmware upgrades. Five independent crossbar modules operate in active-active load-sharing mode; removing any single fabric module does not degrade overall chassis throughput.
Target deployment scenarios: Large virtualized data center core SAN-LAN aggregation, multi-building enterprise campus distributed storage root, hyperscale centralized tape library backup fabric core, large regional mission-critical cross-site disaster recovery SAN gateway, medium-to-large service provider multi-tenant PoP edge director, unified campus-wide SAN-LAN fabrics interoperable with N7K-C7004 compact pod core switches and MDS 9000 SAN directors.
Model Suffix Breakdown
-
N7K: Nexus 7000 modular data center switch platform prefix
-
C7010: Bare empty 10-slot front chassis (8 universal I/O line card slots + 2 dedicated supervisor/fabric slots) plus rear fabric/fan/power subsystems
-
Bare chassis N7K-C7010 has no K9 suffix; bundled SKUs with preloaded supervisors/power supplies carry -2K9 suffix
-
Airflow fixed front-to-back cold intake (no separate E hot-aisle exhaust chassis variant)
3. Chassis Slot & Hardware Layout Definition
Front Panel 10 Horizontal Slots (21RU 19-inch rack)
-
Slots 1,2,3,4,7,8,9,10: Eight universal hot-swappable I/O line/service module slots (40G/10G FCoE Ethernet switching cards, DS-X9334 FCIP multi-protocol extension modules, SSM encryption/asynchronous replication service modules)
-
Slots 5,6: Dedicated redundant Supervisor-2 / Supervisor-2E fabric control module slots (Slot5 defaults active, Slot6 standby)
Rear Panel Redundant Subsystems
-
Up to five independent hot-swappable N7K-C7010-FAB-2 crossbar switching fabric modules (mandatory for full 4.1 Tbps non-blocking bandwidth)
-
Three independent hot-swappable power supply bays supporting AC or DC high-voltage 6000W power modules
-
Two separate hot-swappable multi-fan variable-speed fan assemblies:
-
N7K-C7010-FAN-S: System fan tray for front I/O/supervisor cooling
-
N7K-C7010-FAN-F: Dedicated fabric fan tray for rear crossbar module coolingCisco
Out-of-Band Management Interfaces (each Supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export dedicated interface)
-
External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
-
Physical reset button for factory default configuration recovery
Front Global Diagnostic LED Bank
Chassis system status, power supply A/B/C, system fan tray, fabric fan tray, crossbar module, supervisor module, line card port link activity, hardware fault alarm, UID blue locator beacon indicator
Airflow Specification
Fixed front-to-back airflow: Cold air intake from front panel side, hot air exhausted from rear power/crossbar compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N7K-C7010)Cisco
Supported Transceivers & Pluggable Modules
-
Ethernet/FCoE optical transceivers (sold separately for all line card ports):
-
SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
-
QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
-
Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
-
Supported pluggable I/O line/service modules for Slots 1–4,7–10:
-
N7K-F248XP-25E: 48×10G SFP+ high-density F2 series line card
-
N7K-F248-40GE: 48×40G QSFP+ F2E maximum-density line card (8×48 = 384 total 40G ports full chassis)
-
N7K-M224XP-23L: 24×10G M2 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
-
SSM Storage Services Module: Inline tape/media encryption, asynchronous cross-fabric replication, SAN performance analytics
-
Supervisor module compatibility: Supervisor-2 (N7K-SUP2), Supervisor-2E (N7K-SUP2E upgraded larger memory, enhanced FCoE telemetry NPU) (Supervisor-1 unsupported)
-
Crossbar module compatibility: N7K-C7010-FAB-2 Generation2 crossbar fabric modules (five required for full chassis bandwidth)
-
Power supply compatibility: 6000W Platinum AC PEM modules (N7K-AC-6.0KW-WS), 6000W DC PEM telecom modules (N7K-DC-6.0KW-WS), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Performance Specifications
Core Switching & Routing Performance
-
Single-chassis non-blocking fabric maximum aggregate bandwidth: 4.1 Tbps full-duplex system-wide bandwidth
-
Wire-speed frame forwarding rate: Up to 4100 Mpps Ethernet frame switching at full 40G line rate
-
Low-latency shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
-
MAC address table capacity: 128,000 MAC entries
-
IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
-
Maximum isolated VDC virtual switch contexts: 4 independent logical switch partitions
-
Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
-
Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
-
NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload: FCoE lossless frame processing, FC-NVMe frame tunneling, vPC peer synchronization, OTV overlay encapsulation, LISP endpoint mapping, FCIP tunnel compression/tape acceleration
Power & Cooling System
-
Power supply bays: 3 hot-swappable redundant slots, each 6000W AC PSU fully powers complete chassis independently (N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current, 80 Plus Platinum high efficiency
-
Fan assemblies: Two independent hot-swappable multi-fan trays
-
System fan tray: Front I/O/supervisor cooling
-
Fabric fan tray: Dedicated rear crossbar module cooling
-
Minimum functional fan requirement: At least one full fan tray operational to avoid thermal shutdown; single fan tray failure triggers SNMP fault alert without service interruption
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
-
Typical full-load power draw: 450W fully populated with eight 48-port 40G line cards + dual supervisor modules + five crossbar modules under maximum traffic load
-
MTBF: 220,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 21 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 92.7 cm × 43.9 cm × 84.1 cm (21 rack units, 17.3 × 33.1 inch depth; extended depth 96.5cm with cable management guide installed)
-
Bare chassis weight: 90 kg (200 lbs) without power supplies/fan trays/line/crossbar modules; fully loaded maximum weight 136 kg (300 lbs) with three PSUs, two fan trays, five crossbar modules and eight 48-port line cards installed
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations, FIPS 140-2 Level 2 validated
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access per supervisor: RJ45 RS232 serial port + Mini USB console port
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports
-
External USB flash storage for offline NX-OS firmware and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full NX-OS Multilayer Feature Set (Cisco NX-OS Release 6.x Universal Image)
Layer 2 Ethernet & Converged FCoE Fabric Services
-
VDC Virtual Device Context: Logical virtual switch partitioning to isolate multi-tenant LAN/SAN workloads on single physical chassis
-
Standard VLAN segmentation (4094 VLANs per VDC), PVLAN private VLAN isolation
-
Dual zoning models for FCoE: VSAN virtual storage fabric segmentation, hard WWN zoning + Autozone automatic fabric zoning
-
Complete FCoE protocol stack support: Lossless PFC priority flow control, DCBX, VNTag virtual machine storage I/O tracking, FC-NVMe tunneling
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 10G/40G Ethernet port speeds (max 16-port bundles)
-
DTP dynamic trunk negotiation, MSTP multi-instance spanning tree protocol for Layer 2 loop prevention
-
Local SPAN, RSPAN remote traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation for lossless FCoE traffic
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass pod rack rollouts
Multilayer Routing & Multi-Protocol Data Center Interconnect Features
-
FSPF Fibre Channel Shortest Path First dynamic SAN fabric routing for distributed storage topologies
-
EIGRP / OSPF / BGP IPv4/IPv6 dynamic Layer 3 routing protocols for LAN workloads
-
PIM-SM / PIM-SSM IP multicast for cross-fabric asynchronous backup replication traffic
-
Static IP route configuration, VRF virtual routing and forwarding multi-tenant routing isolation
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated FCoE storage fabrics
-
Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
-
OTV Overlay Transport Virtualization cross-data center layer 2 overlay for disaster recovery workload mobility
-
LISP Locator/ID Separation Protocol for multi-pod workload mobility and DC interconnection
-
FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance cross-site disaster recovery replication
-
iSCSI multi-protocol gateway processing via DS-X9334 service modules for IP-attached server consolidation
Advanced QoS & Traffic Prioritization
-
Four hardware priority queues per Ethernet / FCoE port for tiered classification of storage I/O, virtual machine data, management and backup traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization
Enterprise & Service Provider Security Suite
-
Port security: Static MAC locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE identity services engine
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for FCoE ISL inter-switch link fabric authentication
-
Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 validated security compliance for government and financial regulated environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN/LAN Management Tools
-
Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
-
Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
6. High Availability Capabilities (Core Differentiators vs N7K-C7009 9-Slot Director)
-
Up to three hot-swappable high-efficiency 6000W AC redundant power supplies (N+1 redundant architecture; N7K-C7009 only dual PSUs with limited 1+1 power redundancy)
-
Two separate independent hot-swappable fan trays (system fan tray + dedicated fabric cooling fan tray) for layered redundant cooling (N7K-C7009 only single integrated front fan tray without dedicated crossbar cooling)
-
Eight universal I/O line card expansion slots vs seven on N7K-C7009, supporting up to 384 total 40G FC ports (higher maximum port density)
-
Six independent active-active load-sharing crossbar fabric modules delivering 4.1 Tbps full non-blocking bandwidth (N7K-C7009 reaches higher 8.8 Tbps but uses side-to-side airflow incompatible with standard cold-aisle front-intake racks)
-
Dual redundant Supervisor-2 / Supervisor-2E fabric control modules with stateful failover and ISSU non-disruptive firmware upgrades (shared HA architecture with all Nexus 7000 chassis)
-
Full OIR hot-swap support for all critical FRUs: crossbar modules, fan trays, power supplies, supervisors, line cards without chassis power cycle
-
Front-to-back airflow design optimized for mainstream cold aisle data center rack deployments (N7K-C7009 uses side-to-side airflow, limited rack compatibility)
-
Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation features consistent with all Nexus 7000 family
-
21RU rack footprint for large core aggregation (N7K-C7009 is 14RU, smaller rack height for compact data center pods)
-
Limitation: Fixed eight I/O slot ceiling with no expansion beyond eight built-in line card bays, legacy maximum 40G Ethernet hardware generation, end-of-sale since Feb 2022, hardware support expiring Feb 28, 2027.
7. Typical Deployment Scenarios
-
Large Virtualized Multi-Pod Data Center Core SAN-LAN Director
21RU modular rack form factor deployed as campus central SAN/LAN core director; eight integrated pre-activated 40G F2E line cards populate all I/O slots for 384 total 40G ports connecting distributed building N7K-C7004 pod core switches, primary production all-flash NVMe FCoE storage arrays and massive blade server racks, dual redundant supervisors + five active-active crossbar modules provide zero-failover fabric control-plane and switching redundancy, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN fabrics.
-
Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
Multiple N7K-C7010 mid-large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, dual layered fan trays ensure stable cooling during fan tray maintenance, built-in FCIP hardware offload provision asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Large Regional Mission-Critical Headquarters Converged Storage/LAN Switch
Financial, healthcare and government headquarters deployments require complete triple power + dual fan tray + dual supervisor + five-crossbar hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant isolation features support mixed enterprise and agency workloads in a single mid-large chassis.
-
Medium-to-Large Service Provider Multi-Tenant PoP Edge Switch
Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N7K-C7010 ideal for large metro PoP edge deployments, terminating large-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks with logical VSAN multi-tenant isolation to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and encryption compliance SSM service modules.
-
Legacy Medium-Scale SAN-LAN Fabric Consolidation Migration Switch
Drop-in performance upgrade for aging Nexus 7004 compact pod core switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G high-density port expansion, triple redundant power supplies and modern NX-OS cross-data center OTV/LISP automation workflows.
-
Centralized Medium Enterprise Tape Library Backup Fabric Aggregation Core
Deployed as dedicated backup SAN aggregation core switch, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slot available for high-density host port expansion or SSM encryption/replication compliance service module additions as enterprise storage compliance requirements expand.
8. Standard Package Contents (Bare Chassis N7K-C7010 Base SKU)
1 × N7K-C7010 Nexus 7010 21RU empty modular switch chassis (front-to-back airflow, without fan trays, power supplies, supervisors, line/crossbar modules)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included in Bare Chassis N7K-C7010)
-
Up to three 6000W Platinum AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
-
Two matching hot-swappable variable-speed fan assemblies (N7K-C7010-FAN-S system fan tray + N7K-C7010-FAN-F fabric fan tray)
-
Two redundant Supervisor-2 or Supervisor-2E fabric control modules (mandatory for chassis operation)
-
Five DS-X97-FAB2 crossbar fabric switching modules (mandatory for full chassis bandwidth operation)
-
Optional Nexus 7000 family pluggable I/O line/service modules (48-port 40G F2E switching module, N7K-F248XP-25E 10G line card, N7K-M224XP-23L multi-protocol FCIP/iSCSI gateway module, SSM storage encryption/replication module)
-
DS-SFP-FC10G/40G optical fiber transceivers for all base Ethernet/FCoE ports (backward compatible with legacy 8G FC SFPs)
-
Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FCoE Enabler license, OTV Data Center Interconnect license, IOA I/O Acceleration license, DMM Data Migration Enabler license
-
RS232 serial console rollover cable, mini USB console cable
-
USB flash memory sticks for NX-OS image and configuration storage
-
Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Summary (For Quotation & Datasheet Use)
The Cisco N7K-C7010 is an End-of-Sale 21RU horizontal mid-large modular converged LAN/FCoE data center core switch from the legacy Nexus 7000 Series 40G Generation, supplied bare without power supplies, fan trays, crossbar fabric modules, supervisor modules and pluggable Ethernet/FCoE service line cards (all FRUs sold separately). Built on a 4.1 Tbps non-blocking 40G Fibre Channel five-module active-active crossbar fabric backplane with two dedicated redundant Supervisor-2/2E slots plus eight universal hot-swappable line card expansion slots supporting up to 384 total 40G SFP+ ports (compatible with 10G SFP+ FCoE converged storage traffic), fixed front-to-back cold aisle rack airflow, up to three hot-swappable 6000W Platinum high-efficiency AC redundant power supply bays and two independent interchangeable hot-swappable variable-speed fan assemblies (system fan tray + dedicated fabric cooling fan tray), with full OIR live FRU replacement support. Running legacy Cisco NX-OS multilayer converged LAN/SAN software, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FC-NVMe ultra-low-latency frame processing, lossless FCoE convergence, FICON mainframe compatible storage convergence, OTV cross-data center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP write/tape replication acceleration, DMM non-disruptive data migration, IOA I/O acceleration, onboard NPU real-time streaming SAN telemetry analytics, VMID virtual machine I/O tracking, Autozone automatic fabric zoning, FIPS-compliant enterprise security suite and DCNM centralized SAN fabric REST API automation. Optimized for large virtualized data center core SAN, multi-building enterprise campus core-edge and medium MPLS service provider multi-tenant PoP storage deployments with complete triple power + dual fan + dual supervisor + five-crossbar full redundant hardware architecture; superior to smaller N7K-C7004 compact pod core switches via eight line card slots, maximum 384-port 40G FC density and mainstream front-to-back cold aisle airflow design, limited by legacy maximum 40G Ethernet hardware generation, fixed additional line card expandability ceiling and end-of-sale status with hardware support expiring Feb 28, 2027. Compliant with global safety, EMI, NEBS and RoHS industrial standards.
|
|
|
| Click:10 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|