Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71416135116 |
ProductName: |
N7K-C7009 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco Nexus 7009 (N7K-C7009) Full Product Description
1. Short Overview
Cisco N7K-C7009 is a 14RU flagship modular converged LAN/FCoE data center core switch bare chassis from the Cisco Nexus 7000 series, released Aug 11, 2011, End-of-Sale Feb 28, 2022, Final Hardware Support Expires Feb 28, 2027Cisco. It features a 9-slot front midplane, supports up to 5 external hot-swappable fabric modules, dual redundant Supervisor-2/2E control slots + 7 universal I/O line card slots, side-to-side airflow, dual redundant 6000W power supplies, integrated multi-fan tray, maximum 8.8 Tbps full-duplex non-blocking throughput, runs legacy NX-OS 6.x, delivers native lossless FCoE SAN-LAN convergence, VDC virtual multi-tenant partitioning, OTV cross-DC overlay, LISP workload mobility, full OIR hot-swap FRU maintenance, designed for large enterprise core, multi-pod virtualized data center and medium-large service provider multi-tenant PoP core deploymentsCisco.
Cisco N7K-C7009 Front View
2. Official Product Lifecycle & Chassis Definition
-
Bare chassis PN:N7K-C7009(empty frame without supervisors, fabric modules, power supplies, line cards)
-
Bundled variants: N7K-C7009-B2S2E-R (2×Sup2E + 5×Fab2), N7K-C7009-40G fabric bundles
-
EOL Timeline: EOS Feb 28, 2022; Last HW Support Feb 28, 2027Cisco
Core Hardware Differentiators vs N7K-C7004 Smaller Chassis
-
Expanded slot architecture: 7 universal I/O line card slots (N7K-C7004 only 2), max 336×40G ports vs 96×40G on 7004Cisco
-
Independent external fabric subsystem: Up to 5 hot-swappable N7K-C7009-FAB-2 fabric modules (active-active load-sharing, scalable total bandwidth up to 8.8 Tbps); N7K-C7004 uses distributed embedded fabric ASICs on line cards with no separate fabric modules and only 1.92 Tbps total capacity
-
Larger 14RU rack height (N7K-C7004 =7RU), higher cooling volume for full 7-line-card high-power SFP/QSFP loading
-
Side-to-side airflow (cold intake left front, hot exhaust rear power compartment); N7K-C7004 uses side-to-back airflow, different rack cooling layout compatibilityCisco
-
Unified Nexus 7000 Gen2 module compatibility: All F2/F2E/M2 I/O, Sup2/Sup2E supervisors interchangeable with N7K-C7004 to reduce spare inventory
-
Complete converged LAN+SAN hardware offload: Lossless PFC/DCBX FCoE, FC-NVMe tunneling, full FICON mainframe storage acceleration without external gateway appliances
-
Full OIR hot-swap for all critical FRUs: fabric modules, supervisors, line cards, power supplies, fan tray without chassis power cycle
High-Availability Architecture
All FRUs support OIR Online Insertion and Removal for live maintenance without data plane interruption. Dual identical 6000W AC/DC power supplies deliver 1+1 N+1 redundant power operation; single integrated multi-fan tray provides full chassis cooling, single fan failure triggers SNMP alert and chassis continues operating for tray replacement. VSAN virtual fabric segmentation isolates storage faults; VDC virtual device context separates multi-tenant LAN workloads to prevent broadcast storm leakage. NPV/NPIV FCoE edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to reduce control-plane overhead. Dual supervisor modules (Slot8 active, Slot9 standby) maintain full stateful synchronization, automatic zero-I/O-loss failover and non-disruptive ISSU firmware upgrades. Five independent fabric modules operate in load-sharing mode; removal of any single fabric module does not reduce overall chassis throughput capacity.
Target deployment scenarios: Large virtualized multi-pod data center core aggregation, hyperscale centralized tape library backup fabric root, large regional mission-critical cross-site disaster recovery SAN-LAN gateway, medium-large service provider multi-tenant PoP edge core director, unified campus-wide converged LAN/SAN fabric interoperable with N7K-C7004 compact pod core switches and MDS 9000 SAN directors.
Model Suffix Breakdown
-
N7K: Nexus 7000 modular data center switch platform prefix
-
C7009: Bare empty 9-slot chassis (7 I/O slots + 2 supervisor slots + rear fabric slots)
-
No K9 suffix on bare chassis N7K-C7009; pre-bundled SKUs with supervisors/power supplies carry -2K9 / -B2S2E suffix
-
Airflow: Side-to-side cold intake (no separate hot-aisle exhaust E variant)
3. Chassis Slot & Hardware Layout
Front Panel 9 Horizontal Slots (14RU backplane)
-
Slots 1,2,3,4,5,6,7: Seven universal hot-swappable I/O line card slots (F2/F2E Ethernet/FCoE switching modules, M2 multi-protocol FCIP/iSCSI service modules, SSM encryption/replication service modules)
-
Slots 8,9: Dedicated redundant Supervisor-2 / Supervisor-2E fabric control module slots (Slot8 defaults active, Slot9 standby)
Rear Panel Redundant Subsystems
-
Up to five independent hot-swappable N7K-C7009-FAB-2 fabric switching modules (mandatory for full 8.8 Tbps non-blocking bandwidth)
-
Two independent hot-swappable power supply bays supporting AC or DC high-voltage 6000W PEM modules
-
Single integrated hot-swappable multi-fan variable-speed cooling tray for full chassis layered airflow
Out-of-Band Management Interfaces (each Supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Isolated 10/100/1000BASE-T out-of-band Ethernet management port for remote SSH/Telnet/SNMP administration
-
Onboard compact flash storage partition for NX-OS firmware images and running configuration archives
-
Physical reset button for factory default configuration recovery
Front Global Diagnostic LED Bank
Chassis system status, power supply A/B, fan tray, rear fabric modules, supervisor module, line card port link activity, hardware fault alarm, UID blue locator beacon indicator
Airflow Specification
Fixed side-to-side airflow: Cold air intake from left front side panel, hot air exhausted from rear power/fabric compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N7K-C7009)
Supported Transceivers & Pluggable Modules
-
Ethernet/FCoE optical transceivers (sold separately for all line card ports):
-
SFP+: 10G-SR/LR/ER for 10G Ethernet / lossless FCoE storage traffic
-
QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
-
Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
-
Supported pluggable I/O line/service modules for Slots 1–7:
-
N7K-F248XP-25E: 48×10G SFP+ high-density F2 series line card
-
N7K-F248-40GE: 48×40G QSFP+ F2E maximum-density line card (7×48 = 336 total 40G ports full chassis)
-
N7K-M224XP-23L: 24×10G M2 mixed-feature line card with L4-L7 service offload, FCIP/iSCSI multi-protocol gateway capability
-
SSM Storage Services Module: Inline tape/media encryption, asynchronous cross-fabric replication, SAN performance analytics
-
Supervisor module compatibility: Supervisor-2 (N7K-SUP2), Supervisor-2E (N7K-SUP2E upgraded larger memory, enhanced FCoE telemetry NPU) (Supervisor-1 unsupported)
-
Fabric module compatibility: N7K-C7009-FAB-2 Generation2 fabric modules (five required for full chassis bandwidth, 1–4 modules supported for partial bandwidth scaling)
-
Power supply compatibility: 6000W AC PEM modules (N7K-AC-6.0KW-WS), 6000W DC PEM telecom modules (N7K-DC-6.0KW-WS), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Performance Specifications
Core Switching & Routing Performance
-
Full-chassis non-blocking fabric maximum aggregate bandwidth: 8.8 Tbps full-duplex system-wide bandwidth (5×Fab2 modules fully loaded)Cisco
-
Wire-speed frame forwarding rate: Up to 8800 Mpps Ethernet frame switching at full 40G line rate
-
Low-latency shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
-
MAC address table capacity: 128,000 MAC entries
-
IPv4 unicast route table capacity: 128,000 entries; IPv6 unicast: 64,000 entries; multicast routes: 32,000 entries
-
Maximum isolated VDC virtual switch contexts: 4 independent logical switch partitions
-
Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
-
Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
-
NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload: FCoE lossless frame processing, FC-NVMe frame tunneling, vPC peer synchronization, OTV overlay encapsulation, LISP endpoint mapping, FCIP tunnel compression/tape acceleration
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 6000W AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current
-
Fan tray: Integrated multi-fan variable-speed assembly built into bare chassis; minimum full tray functional to avoid thermal shutdown, single fan failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
-
Typical full-load power draw: 380W fully populated with seven 48-port 40G line cards + dual supervisor modules + five fabric modules under maximum traffic load
-
MTBF: 210,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 14 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 62.2 cm × 44.45 cm × 60.96 cm (14 rack units, 17.5 × 24 inch depth; extended depth 73.66cm with cable management guide installed)Cisco
-
Bare chassis weight: 16.8 kg (37 lbs) without power supplies/fan trays/line/fabric modules; fully loaded maximum weight 28.6 kg (63 lbs) with dual PSUs, fan tray, five fabric modules and seven 48-port line cards installed
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access per supervisor: RJ45 RS232 serial port + Mini USB console port
-
Single isolated 10/100/1000BASE-T out-of-band Ethernet management port
-
External USB flash storage for offline NX-OS firmware and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full NX-OS Multilayer Feature Set (Cisco NX-OS Release 6.x Universal Image)
Layer 2 Ethernet & Converged FCoE Fabric Services
-
VDC Virtual Device Context: Logical virtual switch partitioning to isolate multi-tenant LAN/SAN workloads on single physical chassis
-
Standard VLAN segmentation (4094 VLANs per VDC), PVLAN private VLAN isolation
-
Dual zoning models for FCoE: VSAN virtual storage fabric segmentation, hard WWN zoning + Autozone automatic fabric zoning
-
Complete FCoE protocol stack support: Lossless PFC priority flow control, DCBX, VNTag virtual machine storage I/O tracking, FC-NVMe tunneling
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 10G/40G Ethernet port speeds (max 16-port bundles)
-
DTP dynamic trunk negotiation, MSTP multi-instance spanning tree protocol for Layer 2 loop prevention
-
Local SPAN, RSPAN remote traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation for lossless FCoE traffic
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass pod rack rollouts
Multilayer Routing & Multi-Protocol Data Center Interconnect Features
-
FSPF Fibre Channel Shortest Path First dynamic SAN fabric routing for distributed storage topologies
-
EIGRP / OSPF / BGP IPv4/IPv6 dynamic Layer 3 routing protocols for LAN workloads
-
PIM-SM / PIM-SSM IP multicast for cross-fabric asynchronous backup replication traffic
-
Static IP route configuration, VRF virtual routing and forwarding multi-tenant routing isolation
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated FCoE storage fabrics
-
Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
-
OTV Overlay Transport Virtualization cross-data center layer 2 overlay for disaster recovery workload mobility
-
LISP Locator/ID Separation Protocol for multi-pod workload mobility and DC interconnection
-
FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance cross-site disaster recovery replication
-
iSCSI multi-protocol gateway processing via M2 service modules for IP-attached server consolidation
Advanced QoS & Traffic Prioritization
-
Four hardware priority queues per Ethernet / FCoE port for tiered classification of storage I/O, virtual machine data, management and backup traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
-
DCBX media optimization for converged FCoE LAN/SAN traffic prioritization
Enterprise & Service Provider Security Suite
-
Port security: Static MAC locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE identity services engine
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for FCoE ISL inter-switch link fabric authentication
-
Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 validated security compliance for government and financial regulated environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN/LAN Management Tools
-
Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
-
Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
-
Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts
6. High Availability Capabilities (Core Differentiators vs N7K-C7004 Mid-Size Compact Switch)
-
Dual redundant Supervisor-2 / Supervisor-2E fabric control modules with stateful failover and ISSU non-disruptive firmware upgrades (shared HA architecture with all Nexus 7000 chassis)
-
Seven universal I/O line card expansion slots vs only two on N7K-C7004, supporting up to 336 total 40G FC ports (3.5× maximum port density)
-
Five independent active-active load-sharing external fabric modules delivering 8.8 Tbps full non-blocking bandwidth (N7K-C7004 distributed embedded fabric only 1.92 Tbps total throughput)
-
Dual hot-swappable high-efficiency 6000W AC redundant power supplies (higher power capacity to support full seven line card + five fabric module load)
-
Single integrated multi-fan tray with multi-fan fault tolerance, larger airflow volume for full high-density module loading
-
Full OIR hot-swap support for all critical FRUs: fabric modules, supervisors, line cards, power supplies, fan tray without chassis power cycle
-
Side-to-side airflow design optimized for large enterprise cold aisle rack deployments (N7K-C7004 uses side-to-back airflow)
-
Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation features consistent with all Nexus 7000 family
-
14RU rack footprint for large core aggregation (N7K-C7004 compact 7RU for pod top-of-row edge core)
-
Limitation: Fixed seven I/O slot ceiling with no additional expansion beyond built-in line card bays, legacy maximum 40G Ethernet hardware generation, end-of-sale since Feb 2022, hardware support expiring Feb 28, 2027.
7. Typical Deployment Scenarios
-
Large Virtualized Multi-Pod Data Center Core SAN-LAN Director
14RU modular rack form factor deployed as campus central SAN/LAN core director; seven 48-port 40G F2E line cards populate all I/O slots for 336 total 40G ports connecting distributed building N7K-C7004 pod core switches, primary production all-flash NVMe FCoE storage arrays and massive blade server racks, dual redundant supervisors + five active-active fabric modules provide zero-failover fabric control-plane and switching redundancy, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN fabrics.
-
Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
Multiple N7K-C7009 large core directors deployed per primary data center storage rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, five redundant fabric modules ensure zero throughput loss during fabric module maintenance, built-in FCIP hardware offload provision asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Large Regional Mission-Critical Headquarters Converged Storage/LAN Switch
Financial, healthcare and government headquarters deployments require complete dual power + single multi-fan tray + dual supervisor + five-fabric-module hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant isolation features support mixed enterprise and agency workloads in a single large chassis.
-
Medium-to-Large Service Provider Multi-Tenant PoP Edge Switch
Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N7K-C7009 ideal for large metro PoP edge deployments, terminating large-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slots reserved for future growth in customer port count and encryption compliance SSM service module additions.
-
Legacy Large-Scale SAN-LAN Fabric Consolidation Migration Director
Drop-in performance upgrade for aging Nexus 7004 compact pod core switches, fully backward compatible with existing 10G SFP transceivers while unlocking ultra-high 336-port 40G density, five-module redundant external crossbar fabric and modern NX-OS cross-data center OTV/LISP automation workflows.
-
Hyperscale Centralized Enterprise Tape Library Backup Fabric Core
Deployed as dedicated backup SAN aggregation core director, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slots available for high-density host port expansion or SSM encryption/replication compliance service module additions as enterprise storage capacity expands.
8. Standard Package Contents (Bare Chassis N7K-C7009 Base SKU)
1 × N7K-C7009 Nexus 7009 14RU empty modular switch chassis (side-to-side airflow, integrated multi-fan tray pre-installed)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included in Bare Chassis N7K-C7009)
-
Dual 6000W AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
-
Two redundant Supervisor-2 or Supervisor-2E fabric control modules (mandatory for chassis operation)
-
Up to five N7K-C7009-FAB-2 crossbar fabric switching modules (mandatory for full chassis bandwidth operation)
-
Optional Nexus 7000 family pluggable I/O line/service modules (48-port 40G F2E switching module, N7K-F248XP-25E 10G line card, N7K-M224XP-23L multi-protocol FCIP/iSCSI gateway module, SSM storage encryption/replication module)
-
DS-SFP-FC10G/40G optical fiber transceivers for all base Ethernet/FCoE ports (backward compatible with legacy 1G SFP transceivers)
-
Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FCoE Enabler license, OTV Data Center Interconnect license, IOA I/O Acceleration license, DMM Data Migration Enabler license
-
RS232 serial console rollover cable, mini USB console cable
-
USB flash memory sticks for NX-OS image and configuration storage
-
Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Summary (For Quotation & Datasheet Use)
The Cisco N7K-C7009 is an End-of-Sale 14RU horizontal large modular converged LAN/FCoE data center core switch from the legacy Nexus 7000 Series 40G Generation, supplied bare without power supplies, fan trays, external crossbar fabric modules, supervisor modules and pluggable Ethernet/FCoE service line cards (all FRUs sold separately). Built on an 8.8 Tbps non-blocking 40G Fibre Channel five-module active-active crossbar fabric backplane with two dedicated redundant Supervisor-2/2E slots plus seven universal hot-swappable line card expansion slots supporting up to 336 total 40G QSFP+ ports (compatible with 10G SFP+ lossless FCoE converged storage traffic), fixed side-to-side cold aisle rack airflow with integrated multi-fan cooling tray, dual hot-swappable 6000W Platinum high-efficiency AC redundant power supply bays and full OIR live FRU replacement support. Running legacy Cisco NX-OS multilayer converged LAN/SAN software, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, native lossless FCoE with PFC/DCBX/VNTag, FICON mainframe compatible storage convergence, OTV cross-data center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric REST API automation. Optimized for large virtualized multi-pod data center core SAN, multi-building enterprise campus core-edge and medium-to-large MPLS service provider multi-tenant PoP deployments with complete dual power + three-fan + dual supervisor + five-crossbar full redundant hardware architecture; superior to smaller N7K-C7004 compact pod core switches via seven line card slots, 336-port maximum 40G density and 8.8Tbps full-duplex non-blocking fabric throughput capacity, limited by legacy maximum 40G Ethernet hardware generation, fixed single-direction airflow design without additional line card expandability and end-of-sale status with hardware support expiring Feb 28, 2027. Compliant with global safety, EMI, NEBS and RoHS industrial standards.
|
|
|
| Click:17 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|