Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
7141644716
ProductName:
N7K-C7004
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco Nexus 7004 (N7K-C7004) Full Product Description

1. Short Sales Title

Cisco N7K-C7004 7RU Compact Modular Data Center Core Switch, 4-Slot Passive Midplane Chassis (2 Redundant Supervisor Slots + 2 Universal I/O Line Card Slots), Side-to-Back Airflow, Dual Hot-Swap 6000W AC/DC Power Supplies, Integrated Multi-Fan Tray, Max 192×10G / 96×40G Ethernet Ports, 1.92 Tbps Full-Duplex Distributed Fabric, Legacy NX-OS 6.x Multilayer Data Center OS, Native FCoE SAN-LAN Convergence, VDC Virtual Device Context, vPC, FabricPath, OTV, LISP, Full OIR Hot-Swap FRU Architecture, End-of-Sale Mid-Size Enterprise & Cloud Pod Core Aggregation Switch for Virtualized Server, All-Flash Storage, Cross-DC Disaster Recovery and Multi-Tenant Data Center Workloads
image
N7K-C7004 Front View
image
N7K-C7004 Front Panel Slots

2. Official Product Overview & Lifecycle

The N7K-C7004 is the smallest chassis in Cisco Nexus 7000 modular data center switch family, released Sep 18, 2012, End-of-Sale Feb 28, 2022, Final Hardware Support End Date Feb 28, 2027. It runs unified NX-OS 6.x firmware, fully interoperable with Nexus 7009/7010/7018 larger chassis and Nexus 2000 FEX fabric extenders for end-to-end data center LAN/SAN convergence.

Core Hardware Differentiators vs Larger Nexus 7000 Chassis

  1. Unique 4-slot passive midplane design withno dedicated external fabric modules; distributed fabric ASICs are embedded directly on I/O line cards, simplifying chassis architecture and reducing rack space (7RU height vs 14RU/18RU for 7010/7018)Cisco.
  2. Fixed slot partition: 2 dedicated redundant supervisor slots + only 2 universal I/O module slots (max 2 line cards loaded; Nexus 7010 has 8 I/O slots, 7018 has 16). Maximum port density: 2×48-port 10G F2 line cards = 96×10G, or 2×48-port 40G F2E = 96×40G total portsCisco.
  3. Side-to-back airflow (cold air intake from left front side, hot exhaust rear power compartment); larger Nexus 7010 uses front-to-back airflow, 7009/7018 use side-to-side airflowCisco.
  4. Only supports Supervisor-2 / Supervisor-2E redundant control modules (Sup1 is incompatible); all M2 / F2 / F2E XL I/O modules supported, F1 & non-XL M1 line cards blockedCisco.
  5. Dual redundant 6000W high-wattage Platinum power supplies, single integrated multi-fan tray built into bare chassis (included with N7K-C7004 empty chassis, power supplies sold separately).
  6. Unified NX-OS feature parity with all Nexus 7000 family: full FCoE for SAN-LAN consolidation, VDC virtual switch partitioning, OTV cross-data center overlay, LISP, MPLS, FabricPath, lossless convergence for FC-NVMe workloads.
  7. Compact pod/data center top-of-row core aggregation form factor for medium enterprise, cloud pod, and mid-size service provider PoP deployments, smaller footprint than full-size 7010/7018 directors.

Core High-Availability Design

All field-replaceable units (FRUs: supervisors, I/O line cards, power supplies, fan tray) support OIR Online Insertion and Removal for live hot-swap maintenance without data plane interruption. Dual identical 6000W AC/DC power supplies deliver 1+1 N+1 redundant power operation; single integrated multi-fan tray provides full chassis cooling, single fan failure triggers alarm without immediate shutdown. VSAN virtual fabric segmentation (FCoE) + VDC virtual device context isolate multi-tenant workloads to prevent broadcast fault leakage. Built-in NPV/NPIV FCoE edge mode offloads Fibre Channel host registration to upstream MDS SAN directors to cut control-plane overhead. Dual supervisor modules (Slot3 active, Slot4 standby) maintain full stateful synchronization; zero I/O loss automatic failover upon active supervisor hardware failure, supports non-disruptive ISSU firmware upgrades.
Target deployment scenarios: Mid-size virtualized data center pod core aggregation, medium enterprise campus distributed LAN/SAN root, mid regional mission-critical cross-site disaster recovery gateway, small-to-medium service provider multi-tenant PoP edge switch, unified pod-level SAN-LAN converged deployments fully interoperable with Nexus 7009/7010 large modular switches and MDS 9000 SAN directors.

Model Suffix Breakdown

  • N7K: Nexus 7000 series modular data center switch platform prefix
  • C7004: Empty bare chassis 4-slot model (4 total front slots: 2 I/O + 2 supervisor)
  • Bare chassis PN N7K-C7004 doesnotinclude supervisors, power supplies, line cards; bundled SKUs like N7K-C7004-S2 ship with dual Sup2 + dual AC power supplies + enterprise feature license
  • Airflow fixed side-to-back (no separate E hot-aisle exhaust variant for N7K-C7004)

3. Chassis Slot & Hardware Layout Definition

Front Panel 4 Horizontal Slots (7RU 19-inch rack)

  1. Slots 1, 2: Two universal hot-swappable I/O line card slots (M2 / F2 / F2E XL Ethernet switching modules, FCoE-capable)
  2. Slots 3, 4: Dedicated redundant Supervisor-2 / Supervisor-2E fabric control module slots (Slot3 defaults active, Slot4 standby)

Rear Panel Redundant Subsystems

  1. Two independent hot-swappable 6000W power supply bays supporting AC or DC high-voltage power modules
  2. Integrated fixed multi-fan tray embedded into bare chassis (included with N7K-C7004 base chassis, no separate fan SKU required)

Out-of-Band Management Interfaces (each Supervisor module carries full management ports)

  • RJ45 RS232 serial console port for local CLI access
  • Mini USB dual local console port for laptop zero-cable administration
  • Isolated 10/100/1000BASE-T out-of-band Ethernet management port
  • External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
  • Physical reset button for factory default configuration recovery

Front Global Diagnostic LED Bank

Chassis system status, power supply A/B, fan tray, supervisor module, I/O line card port link activity, hardware fault alarm, UID blue locator beacon indicator

Airflow Specification

Fixed side-to-back airflow: Cold air intake from left front side panel, hot air exhausted from rear power compartment (cold aisle rack standard; no reversed hot-aisle airflow variant available for N7K-C7004)

Supported Transceivers & Pluggable Modules

  1. Ethernet SFP / SFP+ / QSFP transceivers (sold separately for all I/O line card ports):
    • SFP+: 10G-SR/LR/ER for 10G Ethernet / FCoE
    • QSFP+: 40G-SR4/LR4 for 40G Ethernet / long-distance ISL trunk links
    • Backward compatible with legacy 1G SFP transceivers for existing access switch interoperation
  2. Supported pluggable I/O line/service modules for Slots 1–2:
    • N7K-F248XP-25E: 48×10G SFP+ high-density F2 series line card (max 96×10G ports full chassis)
    • N7K-F248-40GE: 48×40G QSFP+ F2E series maximum-density line card (max 96×40G ports full chassis)
    • N7K-M224XP-23L: 24×10G M2 series mixed feature line card with L4-L7 service offload
  3. Supervisor module compatibility: Supervisor-2 (N7K-SUP2), Supervisor-2E (N7K-SUP2E upgraded larger memory, enhanced FCoE telemetry NPU) (Supervisor-1 unsupported)Cisco
  4. Power supply compatibility: 6000W AC PEM modules (N7K-AC-6.0KW-WS), 6000W DC PEM telecom modules (N7K-DC-6.0KW-WS), non-interchangeable between AC/HV chassis variants

4. Hardware & Physical Specifications

Core Switching & Routing Performance

  • Single-chassis distributed fabric maximum aggregate bandwidth: 1.92 Tbps full-duplex system-wide bandwidth
  • Wire-speed frame forwarding rate: Up to 1920 Mpps Ethernet frame switching at full 40G line rate
  • Low-latency shared packet buffer pool per line card, dedicated buffer credit allocation for lossless FCoE storage traffic
  • MAC address table capacity: 128,000 MAC entries
  • IPv4 / IPv6 route table capacity: 128,000 unicast routes, 32,000 multicast routes
  • Maximum isolated VDC virtual switch contexts: 4 independent logical switch partitions
  • Maximum active port-channel bundles: 1024 PortChannels, max 16 ports per logical trunk with dynamic load balancing
  • Supported Ethernet port operating modes: Access, Trunk, FCoE, vPC peer-link, ISL inter-switch trunk, FEX host interface
  • NPV/NPIV native hardware acceleration: Lossless FCoE forwarding for SAN-LAN convergence, offload Fibre Channel fabric registration to upstream MDS directors without core fabric control-plane overhead
  • Native multi-protocol ASIC hardware offload: FCoE lossless frame processing, FC-NVMe frame tunneling, vPC peer synchronization, OTV overlay encapsulation, LISP endpoint mapping

Power & Cooling System

  • Power supply bays: 2 hot-swappable redundant slots, each 6000W AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
  • AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current
  • Fan tray: Integrated multi-fan variable-speed assembly built into bare chassis; minimum full tray functional to avoid thermal shutdown, single fan failure triggers SNMP fault alert
  • Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
  • Typical full-load power draw: 210W fully populated with two 48-port 40G line cards + dual supervisor modules under maximum traffic load
  • MTBF: 230,000 hours under standard enterprise data center operating conditions

Physical & Environmental Parameters

  • Rack form factor: 7 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 30.2 cm × 44.45 cm × 60.96 cm (7 rack units, 17.5 × 24 inch depth; extended depth 73.66cm with cable management guide installed)
  • Bare chassis weight: 11.4 kg (25 lbs) without power supplies/line cards/supervisors; fully loaded maximum weight 18.2 kg (40 lbs) with dual PSUs, dual supervisors and two 48-port line cards installed
  • Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
  • Storage temperature range: -40°C to 70°C (-40°F–158°F)
  • Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations

Control Plane Out-of-Band Management Interfaces

  • Dual local CLI access per supervisor: RJ45 RS232 serial port + Mini USB console port
  • Single isolated 10/100/1000BASE-T out-of-band Ethernet management port
  • External USB flash storage for offline NX-OS firmware and configuration archives
  • Front panel multi-status LED bank providing real-time hardware health visualization

5. Full NX-OS Multilayer Feature Set (Cisco NX-OS Release 6.x Universal Image)

Layer 2 Ethernet & Converged FCoE Fabric Services

  • VDC Virtual Device Context: Logical virtual switch partitioning to isolate multi-tenant LAN/SAN workloads on single physical chassis
  • Standard VLAN segmentation (4094 VLANs per VDC), PVLAN private VLAN isolation
  • Dual zoning models for FCoE: VSAN virtual storage fabric segmentation, hard WWN zoning + Autozone automatic fabric zoning
  • Complete FCoE protocol stack support: Lossless PFC priority flow control, DCBX, VNTag virtual machine storage I/O tracking, FC-NVMe tunneling
  • Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 10G/40G Ethernet port speeds (max 16-port bundles)
  • DTP dynamic trunk negotiation, MSTP multi-instance spanning tree protocol for Layer 2 loop prevention
  • Local SPAN, RSPAN remote traffic mirroring for multi-session performance troubleshooting
  • Per-port broadcast/multicast storm suppression to eliminate fabric-wide broadcast outages
  • NPV N_Port Virtualizer edge switch mode for large-scale core-edge SAN-LAN convergence architecture deployment
  • Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation for lossless FCoE traffic
  • POAP Power On Auto Provisioning zero-touch switch deployment for mass pod rack rollouts

Multilayer Routing & Multi-Protocol Data Center Interconnect Features

  • FSPF Fibre Channel Shortest Path First dynamic SAN fabric routing for distributed storage topologies
  • EIGRP / OSPF / BGP IPv4/IPv6 dynamic Layer 3 routing protocols for LAN workloads
  • PIM-SM / PIM-SSM IP multicast for cross-fabric asynchronous backup replication traffic
  • Static IP route configuration, VRF virtual routing and forwarding multi-tenant routing isolation
  • Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated FCoE storage fabrics
  • Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
  • OTV Overlay Transport Virtualization cross-data center layer 2 overlay for disaster recovery workload mobility
  • LISP Locator/ID Separation Protocol for multi-pod workload mobility and DC interconnection
  • FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance cross-site disaster recovery replication
  • iSCSI multi-protocol gateway processing via M2 service line cards for IP-attached server consolidation

Advanced QoS & Traffic Prioritization

  • Four hardware priority queues per Ethernet / FCoE port for tiered classification of storage I/O, virtual machine data, management and backup traffic
  • Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
  • Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, virtual server east-west traffic, tape backup archives, and disaster recovery replication
  • Dedicated high-priority traffic queue for low-latency real-time unified communications and enterprise database workloads
  • DCBX media optimization for converged FCoE LAN/SAN traffic prioritization

Enterprise & Service Provider Security Suite

  • Port security: Static MAC locking to block unauthorized physical server/storage device attachment
  • RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE identity services engine
  • SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
  • DH-CHAP mutual bidirectional authentication for FCoE ISL inter-switch link fabric authentication
  • Port lockdown, VDC / VSAN read-only access permissions, complete audit logging for all fabric configuration changes
  • FIPS 140-2 validated security compliance for government and financial regulated environments
  • Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
  • IPv6 over Fibre Channel support for modern dual-stack management networks
  • Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering

Monitoring & SAN/LAN Management Tools

  • Cisco DCNM / Fabric Manager centralized graphical converged LAN/SAN fabric monitoring, provisioning and REST API automation
  • Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages and analytics export
  • External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
  • Cisco Discovery Protocol (CDP) automatic Nexus/MDS fabric neighbor device discovery
  • Real-time storage/LAN telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics, onboard NPU streaming analytics export
  • Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
  • GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
  • Onboard Python interpreter + NX-API REST interfaces for custom data center automation scripts

6. High Availability Capabilities (Core Differentiators vs Larger Nexus 7010 10-Slot Director)

  1. Dual redundant Supervisor-2 / Supervisor-2E fabric control modules with stateful failover and ISSU non-disruptive firmware upgrades (shared high-availability architecture with all Nexus 7000 chassis)
  2. Only two universal I/O line card expansion slots vs eight on Nexus 7010, limited maximum port density (96×40G vs 384×40G on 7010)
  3. Distributed embedded fabric ASICs on I/O line cards (no separate external fabric modules required, simplifies chassis maintenance)
  4. Dual hot-swappable high-efficiency 6000W AC redundant power supplies (shared power capacity with Nexus 7010)
  5. Single integrated multi-fan tray with multi-fan fault tolerance (smaller cooling volume than 7010 dual fan tray design)
  6. Full OIR hot-swap support for all critical FRUs: supervisors, line cards, power supplies without chassis power cycle
  7. Side-to-back airflow design optimized for compact pod cold aisle rack deployments (7010 uses front-to-back airflow)
  8. Unified NX-OS software stack with native EVPN, OTV, LISP, VDC, FCoE and REST API automation features consistent with larger Nexus 7000 directors
  9. Compact 7RU rack footprint ideal for small pod top-of-row core aggregation (7010 is 14RU, double rack height)
  10. Limitation: Fixed two I/O slot ceiling with no expansion beyond two line cards, legacy 40G maximum port hardware generation, end-of-sale since Feb 2022, full hardware support expiring Feb 28, 2027.

7. Typical Deployment Scenarios

  1. Mid-Size Virtualized Data Center Pod Core Switch
    Compact 7RU rack form factor deployed as pod top-of-row core aggregation switch; two 48-port 40G F2E line cards populate both I/O slots for 96 total 40G ports connecting distributed rack Nexus 2000 FEX leaf extenders, primary production all-flash NVMe FCoE storage arrays and medium-density blade server racks, dual redundant supervisors provide zero-failover control-plane redundancy, VDC + VSAN segmentation isolates independent departmental production, test and backup converged LAN/SAN fabrics.
  2. Medium Multi-Building Enterprise Campus Core-Edge SAN-LAN Fabric
    Multiple N7K-C7004 pod core switches deployed per building data center rack, utilizing mixed 10G/40G long-distance LR ISL trunk links to interconnect geographically distributed campus storage pods, OTV overlay tunnels provision asynchronous cross-site disaster recovery replication between primary and DR data centers, built-in FCoE hardware offload consolidates separate LAN and SAN switching layers into single chassis.
  3. Medium Regional Mission-Critical Headquarters Converged Storage/LAN Switch
    Financial, healthcare and government headquarters deployments require complete dual power + dual supervisor hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON-compatible FCoE support enables long-distance cross-site DR replication via FCIP tunnels, VDC multi-tenant isolation features support mixed enterprise and agency workloads in a single compact chassis.
  4. Small-to-Medium Service Provider Multi-Tenant PoP Edge Switch
    Native full MPLS/VPLS/EVPN carrier-grade feature set and VDC multi-tenant logical switch isolation make N7K-C7004 ideal for compact metro PoP edge deployments, terminating medium-scale 10G/40G enterprise customer access circuits and multi-port ISL core backbone trunks to separate independent customer LAN/SAN fabrics, unused I/O slot reserved for future growth in customer port count and L4-L7 service M2 line card additions.
  5. Legacy Small-Scale SAN-LAN Fabric Consolidation Migration Switch
    Drop-in performance upgrade for aging Nexus 5000 fixed FCoE switches, fully backward compatible with existing 10G SFP transceivers while unlocking 40G high-density port expansion, VDC virtual multi-tenant partitioning and modern NX-OS cross-data center OTV/LISP automation workflows.
  6. Centralized Medium Enterprise Tape Library Backup Fabric Aggregation Core
    Deployed as dedicated backup SAN aggregation core switch, utilizing multi-port FCIP PortChannel trunk links to primary production FCoE SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused I/O slot available for high-density host port expansion or M2 encryption/replication service line card additions as enterprise storage compliance requirements expand.

8. Standard Package Contents (Bare Chassis N7K-C7004 Base SKU)

1 × N7K-C7004 Nexus 7004 7RU empty modular switch chassis (side-to-back airflow, integrated multi-fan tray included)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension, locking front door, air filter kit
Hardware installation guide, global safety compliance documentation

Items Sold Separately (Not Included in Bare Chassis N7K-C7004)

  • Dual 6000W AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
  • Two redundant Supervisor-2 or Supervisor-2E fabric control modules (mandatory for chassis operation)
  • Optional Nexus 7000 family pluggable I/O line/service modules (48-port 10G F2 switching module, 48-port 40G F2E switching module, M2 multi-protocol FCIP/iSCSI L4-L7 service module)
  • SFP+/QSFP optical fiber transceivers for all line card Ethernet/FCoE ports (backward compatible with legacy 1G SFP transceivers)
  • Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FCoE Enabler license, OTV Data Center Interconnect license
  • RS232 serial console rollover cable, mini USB console cable
  • USB flash memory sticks for NX-OS image and configuration storage
  • Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco N7K-C7004 is an End-of-Sale 7RU compact modular converged LAN/FCoE data center switch from the legacy Nexus 7000 Series 40G Generation, supplied bare without power supplies, supervisor modules and pluggable Ethernet/FCoE I/O line cards (all FRUs sold separately). Built on a 1.92 Tbps non-blocking distributed fabric passive midplane backplane with two dedicated redundant Supervisor-2/2E slots plus two universal hot-swappable I/O line card expansion slots supporting up to 96 total 40G QSFP+ ports (compatible with 10G SFP+ FCoE converged storage traffic), fixed side-to-back cold aisle rack airflow with integrated multi-fan cooling tray, dual hot-swappable 6000W Platinum high-efficiency AC redundant power supply bays and full OIR live FRU replacement support. Running legacy Cisco NX-OS multilayer converged LAN/SAN software, it delivers VDC virtual multi-tenant logical switch partitioning, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, native lossless FCoE with PFC/DCBX/VNTag, FICON mainframe compatible storage convergence, OTV cross-data center overlay, LISP workload mobility, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP cross-site replication acceleration and DCNM centralized converged fabric monitoring. Optimized for mid-size virtualized data center pod core LAN/SAN aggregation, medium enterprise campus edge and small service provider multi-tenant PoP deployments with complete dual power + dual supervisor full redundant hardware architecture; unique among Nexus 7000 chassis via distributed embedded I/O fabric ASICs without separate external fabric modules and compact 7RU rack footprint, limited by only two I/O expansion slots, legacy maximum 40G Ethernet hardware generation and end-of-sale status with hardware support expiring Feb 28, 2027. Compliant with global safety, EMI, NEBS and RoHS industrial standards.
Click:13 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联