Cisco MDS 9513 (DS-C9513) Full Product Description
1. Short Sales Title
Cisco DS-C9513 18RU Flagship Modular Multilayer Fibre Channel SAN Director, 13-Slot Front Midplane + Rear Dual External Crossbar Fabric, 2 Redundant Supervisor Slots + 11 Universal Line/Service Module Slots, Dual Hot-Swap 6000W AC/DC Power Supplies, Dual Independent Hot-Swap Fan Trays (Front Main Fan Tray + Rear Crossbar Fan Tray), Max 528×8G FC Ports, Dual SAN-OS/NX-OS Software Stack, Native FCIP/iSCSI Multi-Protocol Gateway, FICON Mainframe Acceleration, IVR Inter-VSAN Routing, NPV/NPIV Edge Virtualization, Full OIR Hot-Swap FRU Architecture, End-of-Life Large Enterprise & Service Provider Core SAN Director for Hyperscale Virtualized Data Center, Multi-Campus Distributed Storage, Cross-Site Disaster Recovery, Mass Tape Archive and Multi-Tenant Storage Workloads
2. Official Product Overview & Lifecycle
The Cisco DS-C9513 is the flagship empty bare chassis SKU of MDS 9500 series largest modular multilayer Fibre Channel director, released 2006, End-of-Sale Oct 31, 2016, Last Day of Hardware Support Oct 31, 2021, fully obsolete with no active Cisco TAC hardware supportCisco. It runs dual-boot SAN-OS / NX-OS firmware, fully cross-compatible with MDS 9506 / MDS 9509 smaller directors and all MDS 92xx fixed-port switches for unified end-to-end enterprise and service provider SAN fabric management.
Core Hardware Differentiators vs MDS 9506 / MDS 9509
-
Unique external dual crossbar fabric architecture (MDS 9506/9509 use integrated crossbar built into supervisors only): Two independent hot-swappable rear crossbar modules deliver full 8.4 Tbps non-blocking backplane bandwidth; single crossbar failure maintains full chassis throughput without performance degradationCisco.
-
Maximum scalable front slot count: 11 universal hot-swappable line/service module slots (MDS 9509 only 7 line card slots, MDS 9506 only 4), supporting up to 528×8G FC ports fully populated with eleven 48-port DS-X9248-256 8G line cards, industry-leading single-chassis port density for its generation.
-
Dual independent cooling subsystems: Front 15-fan main fan tray + separate rear crossbar cooling fan tray (MDS 9506/9509 only single front fan tray without dedicated crossbar cooling), superior thermal dissipation for full high-density module loading and long-duration 8G SFP operation.
-
Dual redundant Supervisor-2 / Supervisor-2A fabric control modules with doubled memory (2GB RAM on Supervisor-2A) and FCoE forward compatibility, stateful failover, non-disruptive ISSU firmware upgrades; fixed-port MDS switches have single non-replaceable integrated supervisor without fabric redundancyHewle....
-
Dual redundant hot-swappable clock modules at rear midplane (exclusive to MDS 9513) to eliminate clock single point of failure, unavailable on smaller MDS 9506/9509 chassis.
-
Universal module compatibility: Supports full MDS 9000 Gen1/Gen2 portfolio – high-density FC switching cards, MPS multi-protocol gateway modules (2×1G GE for FCIP/iSCSI WAN SAN extension), SSM storage encryption/asynchronous replication service modules, 10G FC long-distance ISL trunk modules, FCoE-capable line cards for converged LAN/SAN workloads.
-
Full native FICON mainframe hardware acceleration for IBM enterprise tape/disk consolidation, a specialized feature unavailable on base fixed MDS switches.
-
Heavy-duty 6000W dual redundant AC/DC power supplies (MDS 9506/9509 only 1900W PSUs insufficient for full 11-slot high-density module power draw).
-
Unified spare part commonality with MDS 9506 / MDS 9509 directors (supervisors, line cards, service modules interchangeable) to reduce enterprise maintenance inventory costs.
Core High-Availability Design
All field-replaceable units (FRUs: supervisors, line cards, crossbar modules, power supplies, front/rear fan trays, clock modules) support OIR Online Insertion and Removal for live hot-swap maintenance without Fibre Channel data plane interruption. Dual identical 6000W auto-ranging AC power supplies deliver 1+1 N+1 redundant power operation; dual independent hot-swappable fan assemblies (front main fan tray + rear crossbar fan tray) provide redundant layered cooling, multiple fan failures trigger alarms while chassis remains operational for FRU replacement. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS core directors to cut control-plane overhead. Dual supervisor modules (Slot7 active, Slot8 standby) maintain full stateful synchronization; zero I/O loss automatic failover upon active supervisor hardware failure. Dual separate crossbar modules operate in active-active load-sharing mode, single crossbar removal does not reduce overall chassis bandwidth. Dual redundant clock modules eliminate timing single point of failure.
Target deployment scenarios: Hyperscale virtualized data center core SAN aggregation, multi-building enterprise campus distributed storage root, hyperscale centralized tape library backup fabric core, large regional mission-critical headquarters cross-site disaster recovery SAN gateway, medium-to-large service provider multi-tenant PoP edge storage director, unified campus-wide SAN deployments fully interoperable with MDS 9200 fixed switches and MDS 9506/9509 modular directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage director bare chassis part number prefix
-
9513: MDS 9500 flagship large modular director series, total 13 front slots (11 line/service card slots + 2 dedicated supervisor/fabric slots) plus rear crossbar/clock/power/fan subsystems
-
No K9 suffix on empty bare metal chassis DS-C9513; complete bundled SKUs like DS-C9513-2K9 include dual Sup-2 + dual AC power supplies + full enterprise feature license
3. Chassis Slot & Hardware Layout Definition
Front Panel 13 Horizontal Slots (19-inch rack, 18RU height)
-
Slots 1,2,3,4,5,6,9,10,11,12,13: 11 universal hot-swappable line/service module slots (FC switching cards / MPS multi-protocol IP gateway / SSM storage service modules / 10G ISL trunk modules)
-
Slots 7, 8: Dedicated redundant supervisor/fabric control module slots (only Supervisor-2 / Supervisor-2A supported; Slot7 default active, Slot8 standby)
-
Front Left Fan Tray: Single integrated hot-swappable multi-fan tray with 15 variable-speed cooling fans for front line card airflow
Rear Panel Redundant Subsystems
-
Two independent hot-swappable crossbar switching fabric modules (active-active load-sharing, mandatory for full 8.4Tbps bandwidth)
-
Separate dedicated rear crossbar fan tray for crossbar module cooling
-
Two independent hot-swappable clock distribution modules (dual redundant timing reference)
-
Two independent hot-swappable power supply bays supporting AC or DC high-voltage power modules
Out-of-Band Management Interfaces (each supervisor module carries full management ports)
-
RJ45 RS232 serial console port for local CLI access
-
Legacy DB-9 industrial COM terminal port
-
Isolated 10/100BASE-T out-of-band Ethernet management port for remote SSH/Telnet/SNMP administration
-
Onboard compact flash storage partition for SAN-OS/NX-OS firmware images and running configuration archives
Front Global Diagnostic LED Bank
Chassis system status, power supply A/B, front/rear fan tray, crossbar module, clock module, supervisor module, line card port link activity, hardware fault alarm, UID blue locator beacon indicator
Airflow Specification
Fixed front-to-back cold air intake (front port/fan tray side), hot air exhausted from rear power/crossbar compartment (cold aisle rack standard only; no reversed hot-aisle airflow variant available for MDS 9513)
Supported Transceivers & Pluggable Modules
-
Fibre Channel SFP transceivers (sold separately for all line card FC ports):
-
DS-SFP-FC2G-SW: 2Gbps short-wave multimode, 500m reach
-
DS-SFP-FC4G-SW: 4Gbps short-wave multimode, 500m reach
-
DS-SFP-FC8G-SW: 8Gbps short-wave multimode, 500m reach
-
DS-SFP-FC8G-LW: 8Gbps long-wave single-mode, 10km reach
-
Backward compatible with legacy 1G FC SFPs for existing storage array interoperation
-
Supported pluggable line/service modules for Slots 1–6,9–13:
-
DS-X9216: 16×4G FC switching module
-
DS-X9224: 24×4G FC switching module
-
DS-X9248-256: 48×8G FC maximum-density line card (11×48 = 528 total FC ports full chassis)
-
MPS-14/2 Multiprotocol Services Module: 14×FC SFP ports + 2×1G copper GE ports for iSCSI / FCIP gateway
-
SSM Storage Services Module: Inline tape encryption, asynchronous cross-fabric replication, SAN performance analytics
-
DS-X9304: 4×10G FC X2 module for high-speed long-distance ISL trunk links
-
Supervisor module compatibility: Supervisor-2 Gen2 fabric module, Supervisor-2A upgraded fabric module (2GB RAM, FCoE support)
-
Crossbar module compatibility: MDS 9513 Crossbar Fabric Module 2 (external dedicated crossbar required, incompatible with MDS 9506/9509 integrated crossbar supervisors)
-
Power supply compatibility: 6000W AC PEM modules (DS-PWR-6000AC), 6000W DC PEM telecom modules (DS-PWR-6000DC), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Single-chassis non-blocking fabric maximum aggregate bandwidth: 8.4 Tbps full-duplex (dual active-active crossbar modules)Cisco
-
Wire-speed frame forwarding rate: Up to 8400 Mpps Fibre Channel frame switching at full 8G line rate per port
-
Low-latency virtual output queuing (VOQ) shared packet buffer pool with configurable buffer credit allocation for long-distance ISL trunk links
-
FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
-
Maximum isolated VSAN virtual fabrics: 4094
-
Maximum active zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
-
Jumbo FC frame MTU support: Up to 9000 bytes
-
Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL), NP (NPV edge host aggregation)
-
Link aggregation: PortChannel multi-port FC ISL trunk bundling, maximum 16 FC ports per logical bundle with dynamic load balancing
-
NPV/NPIV native hardware acceleration: Consolidate thousands of server host ports upstream to MDS core directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload: Full FICON tape/disk processing, FCIP tunnel compression, write acceleration, tape pipelining for cross-site disaster recovery replication, FCoE lossless forwarding (Supervisor-2A only)
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 6000W AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current
-
Fan subsystems: Dual independent hot-swappable fan assemblies
-
Front main fan tray: 15 variable-speed fans for front line card cooling
-
Rear crossbar fan tray: Dedicated variable-speed fans for rear crossbar module cooling
-
Minimum functional fan requirement: At least one full fan tray operational to avoid thermal shutdown; single fan tray failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
-
Typical full-load power draw: 780W fully populated with eleven 48-port 8G line cards + dual supervisor modules + dual crossbar modules under maximum storage traffic load
-
MTBF: 240,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 18 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 22.86 cm × 44.45 cm × 60.96 cm (18 rack units, 17.5 × 24 inch depth; extended depth 73.66cm with cable management guide installed)
-
Bare chassis weight: 21.8 kg (48 lbs) without power supplies/fan trays/line/crossbar modules; fully loaded maximum weight 36.3 kg (80 lbs) with dual PSUs, dual fan trays, dual crossbar modules and eleven 48-port line cards installed
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access per supervisor: RJ45 RS232 serial port + legacy DB-9 COM terminal port
-
Dedicated isolated 10/100BASE-T out-of-band Ethernet management port per supervisor
-
Onboard flash storage for offline SAN-OS/NX-OS firmware and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full SAN-OS / NX-OS Multilayer Feature Set (SAN-OS 3.x / NX-OS 5.x / 6.x)
Layer 2 Fibre Channel Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
-
Dual zoning models: Hard port zoning and soft WWN Smart Zoning for granular host-storage access control
-
Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 2G/4G/8G FC port speeds (max 16-port bundles)
-
DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
-
Local SPAN, RSPAN, ESPAN enhanced remote SAN traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass access rack rollouts
-
FCoE lossless Ethernet convergence (Supervisor-2A required) with PFC, DCBX, VNTag virtual machine storage I/O tracking
Multilayer Storage Routing & Multi-Protocol Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
-
PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
-
Static FC route configuration for controlled inter-VSAN storage data movement
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSAN fabrics
-
FCIP + iSCSI multi-protocol gateway processing via MPS service modules for IP WAN cross-site SAN extension
-
FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance disaster recovery replication
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered classification of storage I/O traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP database workloads, all-flash NVMe storage, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency virtual machine and enterprise database I/O workloads
-
Medianet media optimization for enterprise video and telepresence storage workflows
Enterprise & Service Provider SAN Security Suite
-
Port security: Static WWN locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
-
Port lockdown, VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 validated security compliance for government and financial regulated environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN Management Tools
-
Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and REST API automation
-
Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS/SAN-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, latency, frame error counters, SFP optical transmit power diagnostics
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
-
Onboard Python interpreter + NX-API REST interfaces for custom SAN automation scripts
6. High Availability Capabilities (Core Differentiators vs MDS 9509-K9 8G Model)
-
Dual independent external crossbar fabric modules (active-active load-sharing, MDS 9509 only integrated single crossbar on supervisors) delivering full 8.4Tbps non-blocking bandwidth
-
11 universal line card expansion slots vs only seven on MDS 9509, supporting up to 528 total 8G FC ports (nearly double MDS 9509’s 336-port ceiling)
-
Dual redundant hot-swappable clock modules (unique to MDS 9513) eliminating timing single point of failure
-
Dual separate front + rear hot-swappable fan trays for layered redundant cooling (MDS 9509 only single front fan tray without dedicated crossbar cooling)
-
Dual hot-swappable high-capacity 6000W AC redundant power supplies (MDS 9509 only 1900W PSUs insufficient for full 11-slot high-density module power draw)
-
Full OIR hot-swap support for all critical FRUs: crossbar modules, clock modules, fan trays, supervisors, line cards, power supplies without chassis power cycle
-
Dual Supervisor-2A upgrade option with doubled memory and native FCoE convergence hardware offload
-
Unified spare part inventory shared with MDS 9506/9509 directors to reduce enterprise maintenance costs
-
VSAN fabric isolation limits fault domains to single virtual storage segment, preventing fabric-wide RSCN broadcast storms
-
Limitation: Legacy 8G Fibre Channel generation hardware only, no native 16G/32G/64G FC support, fixed front-to-back single-direction airflow, legacy SAN-OS/NX-OS firmware stack lacking modern EVPN-FC, containerized automation and cloud-native features, end-of-support since October 31, 2021.
7. Typical Deployment Scenarios
-
Hyperscale Virtualized Data Center Core SAN Director
18RU modular rack form factor deployed as campus central SAN core director; eleven 48-port 8G line cards populate all line card slots for 528 total FC ports connecting distributed building MDS 92xx edge switches, primary production all-flash NVMe storage arrays and massive blade server racks, dual redundant supervisors + dual active-active crossbar modules provide zero-failover fabric control-plane and switching redundancy, VSAN segmentation isolates independent departmental production, test and backup storage fabrics for thousands of virtual machines.
-
Large Multi-Building Enterprise Campus Core-Edge SAN Fabric
Multiple DS-C9513 flagship directors deployed per data center storage rack, utilizing mixed 4G/8G FC long-distance LW ISL trunk links to interconnect geographically distributed campus storage pods, dual crossbar fabric ensures zero throughput loss during crossbar module maintenance, built-in FCIP gateway modules provision asynchronous cross-site disaster recovery replication tunnels between primary and DR data centers.
-
Large Regional Mission-Critical Headquarters SAN
Financial, healthcare and government headquarters storage deployments require complete dual power + dual fan tray + dual supervisor + dual crossbar hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON mainframe support enables long-distance cross-site DR replication, while MPLS multi-tenant VSAN isolation features support mixed enterprise and agency storage workloads in a single space-efficient flagship chassis.
-
Medium-to-Large Service Provider Multi-Tenant PoP Edge Storage Gateway
Native full MPLS/VPLS/EVPN carrier-grade feature set and massive FC address table scale make DS-C9513 ideal for carrier PoP edge deployments, terminating hundreds of 8G enterprise customer access circuits and high-speed multi-port ISL core backbone trunks with logical VSAN multi-tenant isolation to separate independent customer storage fabrics, unused line card slots reserved for future growth in customer port count and encryption compliance service modules.
-
Legacy MDS 9506 / MDS 9509 SAN Hardware Refresh Migration Upgrade
Drop-in performance upgrade for smaller MDS modular directors, fully backward compatible with existing 2G/4G Fibre Channel SFP transceivers while unlocking ultra-high 528-port density, dual redundant external crossbar fabric, dual clock redundancy, layered dual cooling subsystems and modern NX-OS automation workflows.
-
Hyperscale Centralized Enterprise Tape Library Backup Fabric Core
Deployed as dedicated backup SAN aggregation core director, utilizing multi-port FCIP PortChannel trunk links to primary production SAN fabrics via asynchronous off-site tape archive and disaster recovery replication workloads, with unused line card slots available for high-density host port expansion or SSM encryption/replication compliance service module additions as enterprise storage capacity expands.
8. Standard Package Contents (Bare Chassis DS-C9513 Base SKU)
1 × DS-C9513 MDS 9513 18RU flagship modular SAN director empty chassis (front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included in Bare Chassis DS-C9513)
-
Dual 6000W AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
-
Dual matching hot-swappable variable-speed fan assemblies (front main fan tray + rear crossbar fan tray)
-
Two redundant Supervisor-2 or Supervisor-2A fabric control modules (mandatory for chassis operation)
-
Two dedicated MDS 9513 external crossbar switching fabric modules (mandatory for full bandwidth operation)
-
Dual redundant hot-swappable clock distribution modules
-
Optional MDS 9000 family pluggable line/service modules (48-port 8G FC switching module, MPS-14/2 multi-protocol FCIP/iSCSI gateway module, SSM storage encryption/replication module, 4-port 10G ISL trunk module)
-
DS-SFP-FC2G-SW / DS-SFP-FC4G-SW / DS-SFP-FC8G-SW / DS-SFP-FC8G-LW Fibre Channel SFP optical transceivers for all line card FC ports (backward compatible with 1G FC SFPs)
-
Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FICON Enabler license, IOA I/O Acceleration license, DMM Data Migration Enabler license
-
RS232 serial console rollover cable, mini USB console cable
-
USB flash memory sticks for NX-OS/SAN-OS image and configuration storage
-
Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9513 is an End-of-Life obsolete 18RU horizontal flagship modular Fibre Channel SAN fabric director from the MDS 9500 Series 8G Generation, supplied bare without power supplies, fan trays, crossbar modules, clock modules, supervisor modules and pluggable FC/service line cards (all FRUs sold separately). Built on an 8.4 Tbps non-blocking 8G Fibre Channel dual external crossbar fabric backplane with two dedicated redundant supervisor/fabric slots plus eleven universal hot-swappable line card expansion slots supporting up to 528 total 8G FC ports, fixed front-to-back cold aisle rack airflow, dual hot-swappable 6000W high-capacity AC redundant power supply bays and two independent interchangeable hot-swappable fan assemblies (front main fan tray + rear crossbar cooling fan tray) with full OIR live FRU replacement support. Running dual-boot Cisco SAN-OS / NX-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, FICON mainframe support, integrated multi-protocol FCIP/iSCSI IP SAN extension via pluggable MPS service modules, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP write/tape replication acceleration, optional DMM non-disruptive data migration, IOA I/O acceleration, native FCoE lossless convergence (Sup-2A), VMID virtual machine I/O tracking, FIPS-compliant enterprise security suite and DCNM centralized SAN fabric monitoring. Optimized for hyperscale virtualized data center core SAN, multi-building enterprise campus core-edge and large MPLS service provider multi-tenant PoP storage deployments with complete dual power + dual fan + dual crossbar + dual clock + dual supervisor full redundant hardware architecture; unique among all MDS 9500 directors with external dual active-active crossbar fabric and dual redundant clock subsystems, superior to MDS 9506/9509 via ultra-high 528-port density and layered redundant cooling, limited by legacy 8G Fibre Channel generation, fixed single-direction airflow and outdated SAN-OS/NX-OS firmware without modern 16G/32G FC hardware and cloud-native automation features. Compliant with global safety, EMI, NEBS and RoHS industrial standards, official Cisco TAC hardware support fully terminated October 31, 2021.
|
|
|
| Click:17 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|