Product_Id:
71415391716
ProductName:
DS-C9509
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco MDS 9509 (DS-C9509) Full Product Description

1. Short Sales Title

Cisco DS-C9509 14RU Large Modular Multilayer Fibre Channel SAN Director, 9-Slot Backplane (2 Redundant Supervisor Slots + 7 Universal Line Card Slots), Dual Hot-Swap 1900W AC/DC Redundant Power Supplies, Single Hot-Swap 9-Fan Tray, Max 336×8G FC Ports, Legacy SAN-OS Multilayer Storage OS, Native VSAN, IVR Inter-VSAN Routing, FCIP/iSCSI Multi-Protocol Gateway, FICON Mainframe Acceleration, NPV/NPIV Edge Virtualization, Full OIR Hot-Swap FRU Architecture, End-of-Life Enterprise Core SAN Director for Large Virtualized Data Center, Multi-Building Distributed Storage, Cross-Site Disaster Recovery, Tape Archive and Multi-Tenant Service Provider Storage Workloads

2. Official Product Overview & Lifecycle

The Cisco DS-C9509 is the base empty chassis SKU of MDS 9509 large modular multilayer Fibre Channel director within Cisco MDS 9500 series, released 2004, End-of-Sale April 2013, Last Day of Hardware Support April 30, 2018, fully obsolete with no official Cisco TAC hardware support. It runs legacy SAN-OS firmware, fully cross-compatible with MDS 9506 / MDS 9513 directors and all MDS 92xx fixed-port switches for unified end-to-end enterprise SAN fabric managementCisco.

Core Hardware Differentiators vs Smaller MDS 9506 & Fixed MDS 92xx/93xx Switches

  1. Massive scalable 9-slot backplane architecture: 2 dedicated redundant supervisor/fabric slots +7 universal hot-swappable line/service module slots(MDS 9506 only 4 line card slots; all MDS 91/92/93xx switches are fixed-port with zero or one limited expansion slot)Cisco.
  2. Dual redundant Supervisor-1 / Supervisor-2 crossbar fabric modules with stateful failover, non-disruptive ISSU firmware upgrades, independent crossbar switching planes; fixed switches have single non-replaceable integrated supervisor without fabric redundancyCisco.
  3. Industry-leading maximum port density: Up to 336×8G FC ports when fully loaded with seven 48-port DS-X9248-256 8G line cards, far exceeding MDS 9506’s 192-port ceiling and single fixed switch 96-port maximum.
  4. Universal module compatibility: Supports full MDS 9000 service portfolio – high-density FC switching cards, MPS multi-protocol gateway modules (2×1G GE for FCIP/iSCSI WAN SAN extension), SSM storage encryption/asynchronous replication service modules, 10G ISL trunk modules for metro long-distance inter-fabric links.
  5. Full native FICON mainframe hardware acceleration for IBM enterprise tape/disk consolidation, a specialized feature unavailable on base fixed MDS switches.
  6. Enterprise-grade redundant FRU architecture: Dual hot-swappable high-wattage power supplies, single integrated nine-fan hot-swappable cooling tray, all FRUs support OIR live replacement without Fibre Channel data plane interruptionCisco.
  7. Unified spare part commonality with MDS 9506 / MDS 9513 directors (supervisors, power supplies, fan trays, all pluggable line cards interchangeable) to reduce enterprise maintenance inventory costsCisco.

Core High-Availability Design

All field-replaceable units (FRUs: supervisors, line cards, power supplies, fan tray) support OIR Online Insertion and Removal for live hot-swap maintenance without SAN traffic outage. Dual identical 1900W auto-ranging AC power supplies deliver 1+1 N+1 redundant power operation; single integrated hot-swappable nine-fan tray provides full chassis cooling, single fan failure triggers alarm while chassis remains operational for tray replacement. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS core directors to cut control-plane overhead. Dual supervisor modules (Slot 8 active, Slot 9 standby) maintain full stateful synchronization; zero I/O loss automatic failover upon active supervisor hardware failureCisco.
Target deployment scenarios: Large virtualized data center core SAN aggregation, multi-building enterprise campus distributed storage root, hyperscale centralized tape library backup fabric core, large regional mission-critical headquarters cross-site disaster recovery SAN gateway, medium-to-large service provider multi-tenant PoP edge storage director, unified campus-wide SAN deployments fully interoperable with MDS 9200 fixed switches and MDS 9506/9513 modular directors.

Model Suffix Breakdown

  • DS-C: Cisco MDS storage director bare chassis part number prefix
  • 9509: MDS 9500 large modular director series, total 9 internal slots (7 line/service card slots + 2 dedicated supervisor/fabric slots)
  • No K9 suffix on empty base chassis DS-C9509; complete bundled SKUs like DS-C9509-2K9 include dual Sup-2 + dual AC power supplies + enterprise feature license

3. Chassis Slot & Hardware Layout Definition

  1. Nine total internal slots on 14RU backplane
    • Slots 1–7: Universal hot-swappable line/service module slots (FC switching cards, MPS multi-protocol IP gateway, SSM encryption/replication modules)
    • Slots 8, 9: Dedicated redundant supervisor/fabric module slots (only Supervisor-1 / Supervisor-2 fabric cards supported; Slot8 defaults active, Slot9 standby)Cisco
  2. Front Fan Tray: Single integrated hot-swappable multi-fan tray with nine variable-speed cooling fans for full chassis airflow
  3. Rear Power Compartment: Two independent hot-swappable power supply bays supporting AC or DC high-voltage power modules
  4. Out-of-Band Management Interfaces (each supervisor module carries full management ports)
    • RJ45 RS232 serial console port for local CLI access
    • Legacy DB-9 industrial COM terminal port
    • Isolated 10/100BASE-T Ethernet out-of-band management port for remote SSH/Telnet/SNMP administration
    • Onboard compact flash storage partition for SAN-OS firmware images and running configuration archives
  5. Front Global Diagnostic LED Bank: Chassis system status, power supply A/B, fan tray, supervisor module, line card port link activity, hardware fault alarm, UID blue locator beacon indicator
  6. Airflow Specification: Fixed front-to-back cold air intake (port/fan tray side), hot air exhausted from rear power supply compartment (cold aisle rack standard only; no reversed hot-aisle airflow variant available for MDS 9509)

Supported Transceivers & Pluggable Modules

  1. Fibre Channel SFP transceivers (sold separately for all line card FC ports):
    • DS-SFP-FC2G-SW: 2Gbps short-wave multimode, 500m transmission reach
    • DS-SFP-FC4G-SW: 4Gbps short-wave multimode, 500m transmission reach
    • DS-SFP-FC8G-SW: 8Gbps short-wave multimode, 500m transmission reach
    • DS-SFP-FC8G-LW: 8Gbps long-wave single-mode, 10km transmission reach
    • Backward compatible with legacy 1G FC SFPs for existing storage array interoperation
  2. Supported pluggable line/service modules for Slots 1–7:
    • DS-X9216: 16×4G FC switching module
    • DS-X9224: 24×4G FC switching module
    • DS-X9248-256: 48×4G FC high-density line card
    • DS-X9248-8G: 48×8G FC maximum-density line card (7×48 = 336 total FC ports full chassis)
    • MPS-14/2 Multiprotocol Services Module: 14×FC SFP ports + 2×1G copper GE ports for iSCSI / FCIP SAN extension gateways
    • SSM Storage Services Module: Inline tape/media encryption, asynchronous cross-fabric replication, SAN performance analytics
    • DS-X9304: 4×10G FC X2 module for high-speed long-distance ISL trunk links
  3. Supervisor module compatibility: Supervisor-1 Gen1 fabric module, Supervisor-2 Gen2 upgraded fabric module (higher throughput, expanded buffer pools, 8G FC hardware offload support)
  4. Power supply compatibility: 1900W AC PEM modules (DS-PWR-1900AC), 1900W DC PEM telecom modules (DS-PWR-1900DC), non-interchangeable between AC/HV chassis variants

4. Hardware & Physical Specifications

Core SAN Switching & Routing Performance

  • Single-chassis non-blocking fabric maximum aggregate bandwidth: 2.688 Tbps full-duplex (fully populated with seven 48-port 8G line cards)
  • Wire-speed frame forwarding rate: Up to 2688 Mpps Fibre Channel frame switching at full 8G line rate per port
  • Low-latency virtual output queuing (VOQ) shared packet buffer pool with configurable buffer credit allocation for long-distance ISL trunk links
  • FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
  • Maximum isolated VSAN virtual fabrics: 4094
  • Maximum active zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
  • Jumbo FC frame MTU support: Up to 9000 bytes
  • Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL), NP (NPV edge host aggregation)
  • Link aggregation: PortChannel multi-port FC ISL trunk bundling, maximum 16 FC ports per logical bundle with dynamic load balancing
  • NPV/NPIV native hardware acceleration: Consolidate thousands of server host ports upstream to MDS core directors without core fabric control-plane overhead
  • Native multi-protocol ASIC hardware offload: Full FICON tape/disk processing, FCIP tunnel compression, write acceleration, tape pipelining for cross-site disaster recovery replication

Power & Cooling System

  • Power supply bays: 2 hot-swappable redundant slots, each 1900W AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
  • AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current
  • Fan tray: Single integrated hot-swappable nine-fan variable-speed assembly; minimum full tray functional to avoid thermal shutdown, single fan failure triggers SNMP fault alert
  • Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
  • Typical full-load power draw: 410W fully populated with seven 48-port 8G line cards + dual supervisor modules under maximum storage traffic load
  • MTBF: 250,000 hours under standard enterprise data center operating conditions

Physical & Environmental Parameters

  • Rack form factor: 14 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 17.78 cm × 44.45 cm × 57.82 cm (14 rack units, 17.5 × 22.75 inch depth; extended depth 70.37cm with cable management guide installed)
  • Bare chassis weight: 16.8 kg (37 lbs) without power supplies/fan tray/line cards; fully loaded maximum weight 26.3 kg (58 lbs) with dual PSUs, fan tray and seven 48-port line cards installed
  • Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
  • Storage temperature range: -40°C to 70°C (-40°F–158°F)
  • Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations

Control Plane Out-of-Band Management Interfaces

  • Dual local CLI access per supervisor: RJ45 RS232 serial port + legacy DB-9 COM terminal port
  • Dedicated isolated 10/100BASE-T out-of-band Ethernet management port per supervisor
  • Onboard flash storage for offline SAN-OS firmware and configuration archives
  • Front panel multi-status LED bank providing real-time hardware health visualization

5. Full SAN-OS Multilayer Feature Set (Cisco SAN-OS Release 1.x / 2.x / 3.x)

Layer 2 Fibre Channel Fabric Services

  • VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
  • Dual zoning models: Hard port zoning and soft WWN Smart Zoning for granular host-storage access control
  • Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
  • Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 2G/4G/8G FC port speeds (max 16-port bundles)
  • DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
  • Local SPAN, RSPAN remote SAN traffic mirroring for multi-session performance troubleshooting
  • Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
  • NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
  • Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation
  • POAP Power On Auto Provisioning zero-touch switch deployment for mass access rack rollouts

Multilayer Storage Routing & Multi-Protocol Features

  • FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
  • PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
  • Static FC route configuration for controlled inter-VSAN storage data movement
  • Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSAN fabrics
  • FCIP + iSCSI multi-protocol gateway processing via MPS service modules for IP WAN cross-site SAN extension
  • FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance disaster recovery replication

Advanced SAN QoS & Traffic Prioritization

  • Four hardware priority queues per Fibre Channel port for tiered classification of storage I/O traffic
  • Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
  • Pre-built QoS templates for production OLTP database workloads, tape backup archives, and disaster recovery replication streams
  • Dedicated high-priority traffic queue for low-latency virtual machine and enterprise database I/O workloads

Enterprise SAN Security Suite

  • Port security: Static WWN locking to block unauthorized physical server/storage device attachment
  • RBAC Role-Based Access Control granular CLI user privilege partitioning with multi-tier administrator access
  • SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
  • DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
  • VSAN read-only access permissions, port lockdown controls, complete audit logging for all fabric configuration changes
  • Compatibility with MDS SSM encryption and remote replication service modules for data-at-rest tape security

Monitoring & SAN Management Tools

  • Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and reporting
  • Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages
  • Onboard flash storage for SAN-OS firmware image upgrades, configuration backup archives and syslog export
  • Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
  • Real-time storage telemetry: Port throughput, I/O latency, frame error counters, SFP optical transmit power diagnostics
  • Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
  • GOLD Generic Online Diagnostics continuous background hardware health validation without traffic interruption

6. High Availability Capabilities (Core Differentiators vs MDS 9506-K9 Smaller Director)

  1. Dual redundant Supervisor-1/Supervisor-2 fabric modules with stateful failover and ISSU non-disruptive firmware upgrades (MDS 9506 also dual supervisors, but smaller crossbar bandwidth)
  2. Seven universal line card expansion slots vs only four on MDS 9506, supporting nearly double maximum FC port density (336 vs 192)
  3. Dedicated integrated high-capacity crossbar fabric on each supervisor for full non-blocking chassis throughput
  4. Dual hot-swappable high-wattage 1900W AC redundant power supplies (shared with MDS 9506, but larger chassis cooling capacity for full high-density line card loads)
  5. Full native multi-protocol FCIP/iSCSI gateway capability via MPS service modules, plus full FICON mainframe hardware acceleration built into supervisor ASICs
  6. Unified spare part inventory shared with MDS 9506 directors to reduce enterprise maintenance costs
  7. OIR hot-swap support for all major FRUs (supervisors, line cards, power supplies, fan tray) without chassis power cycle
  8. Limitation: Legacy 8G Fibre Channel generation hardware only, no native 16G/32G/64G FC support, fixed front-to-back airflow only, legacy SAN-OS firmware stack lacking modern NX-OS automation, EVPN-FC and REST API features, end-of-support since April 30, 2018.

7. Typical Deployment Scenarios

  1. Large Virtualized Multi-Building Enterprise Core SAN Director
    14RU modular rack form factor deployed as campus central SAN core director; seven 48-port 8G line cards populate all line card slots for 336 total FC ports connecting distributed building MDS 92xx edge switches, primary production all-flash storage arrays and dense blade server racks, dual redundant supervisors provide zero-failover fabric control-plane redundancy, VSAN segmentation isolates independent departmental production, test and backup storage fabrics.
  2. Large Regional Mission-Critical Headquarters SAN
    Financial, healthcare and government headquarters storage deployments require complete dual power + dual supervisor + redundant line card hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON mainframe support enables long-distance cross-site DR replication via FCIP IP extension provisioned on MPS-14/2 multi-protocol expansion modules.
  3. Medium-to-Large Service Provider Multi-Tenant PoP Edge Storage Director
    VSAN multi-tenant isolation feature logically separates dozens of independent enterprise customer storage fabrics on a single physical MDS 9509 director chassis, scalable high-density 48-port line cards support growing customer base port count demand, FCIP gateway modules provide metro WAN inter-PoP storage trunk links between geographically distributed customer sites.
  4. Mixed-Generation MDS SAN Fabric Consolidation Migration Director
    Interoperable bridge director between older 2G MDS 9200 fixed edge switches and modern MDS 9500 series core infrastructure, fully backward compatible with legacy 1G/2G FC SFPs while providing scalable 8G high-density port expansion and uniform SAN-OS management across mixed-generation MDS hardware fleets.
  5. Hyperscale Centralized Enterprise Tape Library Backup Fabric Core
    Deployed as dedicated backup SAN aggregation core director, utilizing multi-port ISL PortChannel trunk links to primary production SAN fabrics via FCIP asynchronous off-site tape archive and disaster recovery replication workloads, with unused line card slots reserved for future encryption/replication SSM service module additions as compliance storage requirements expand.

8. Standard Package Contents (Bare Chassis DS-C9509 Base SKU)

1 × DS-C9509 MDS 9509 14RU modular Fibre Channel SAN switch empty chassis (front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety compliance documentation

Items Sold Separately (Not Included in Bare Chassis DS-C9509)

  • Dual 1900W AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
  • Single integrated hot-swappable nine-fan variable-speed fan tray
  • Two redundant Supervisor-1 or Supervisor-2 fabric modules (mandatory for chassis operation)
  • Optional MDS 9000 family pluggable line/service modules (48-port 8G FC switching module, MPS-14/2 multi-protocol FC/iSCSI gateway module, SSM storage encryption/replication module, 4-port 10G ISL module)
  • DS-SFP-FC2G-SW / DS-SFP-FC4G-SW / DS-SFP-FC8G-SW / DS-SFP-FC8G-LW Fibre Channel SFP optical transceivers for all line card FC ports (backward compatible with 1G FC SFPs)
  • Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FICON Enabler license
  • RS232 serial console rollover cable, DB-9 COM terminal cable
  • Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco DS-C9509 is an End-of-Life obsolete 14RU horizontal large modular Fibre Channel SAN fabric director from the MDS 9500 Series 8G Generation, supplied bare without power supplies, fan trays, supervisor modules and pluggable FC/service line cards (all FRUs sold separately). Built on a 2.688 Tbps non-blocking 8G Fibre Channel fabric backplane with two dedicated redundant supervisor/fabric slots plus seven universal hot-swappable line card expansion slots supporting up to 336 total 8G FC ports, fixed front-to-back cold aisle rack airflow, dual hot-swappable 1900W high-wattage AC redundant power supply bays and single integrated nine-fan hot-swappable cooling tray with OIR live FRU replacement support. Running legacy Cisco SAN-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, full FICON mainframe support, multi-protocol FCIP/iSCSI IP SAN extension via pluggable MPS service modules, port zoning, NPV/NPIV edge scaling, hardware-accelerated cross-site replication acceleration and DCNM centralized SAN fabric monitoring. Optimized for large virtualized multi-floor distribution SAN, hyperscale centralized tape backup core and medium-to-large carrier multi-tenant PoP edge deployments with complete dual power + dual supervisor hardware redundancy; superior to smaller MDS 9506 directors via seven expansion slots and nearly double maximum FC port density, limited by legacy 8G Fibre Channel generation, single fan tray fault resilience and outdated SAN-OS feature stack without modern NX-OS automation or high-speed 16G/32G FC hardware support. Compliant with global safety, EMI, NEBS and RoHS industrial standards, official Cisco TAC hardware support fully terminated April 30, 2018.
Click:15 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联