Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71415341816 |
ProductName: |
DS-C9506 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco MDS 9506 (DS-C9506) Full Product Description
1. Short Sales Title
Cisco DS-C9506 7RU Modular Multilayer Fibre Channel SAN Director, 6-Slot Backplane (2 Dual Redundant Supervisor Slots + 4 Universal Line Card Slots), Dual Hot-Swap 1900W AC/DC Power Supplies, Single Hot-Swap 6-Fan Tray, Up to 192 4G FC Ports, SAN-OS Multilayer Storage OS, VSAN, IVR, FCIP/iSCSI Multi-Protocol Gateway, FICON Mainframe Acceleration, NPV/NPIV, OIR Hot-Swap FRU Design, End-of-Life Legacy Mid-Size Enterprise Core SAN Director for Multi-Floor Virtualized Server, Tape Backup, Cross-Site Disaster Recovery and Multi-Tenant Storage Workloads
2. Official Product Overview & Lifecycle
The Cisco DS-C9506 (MDS 9506) is the base 6-slot modular multilayer storage director in Cisco MDS 9500 chassis family, released 2005, End-of-Sale Oct 31, 2016, Last Day of Hardware Support April 30, 2022, fully obsolete with no active Cisco TAC hardware supportCisco. It runs legacy SAN-OS firmware, cross-compatible with MDS 9200 fixed switches and MDS 9509/9513 larger directors for unified end-to-end SAN fabric management. Two hardware generations exist: original MDS 9506 Gen1 and MDS 9506 V2 (improved power/thermal subsystem).
Core Hardware Differentiators vs Fixed MDS 92xx / MDS 93xx Switches
-
True modular director backplane architecture with dedicated redundant supervisor fabric slots (Slots 5/6) + four universal line card slots (Slots 1–4), supporting hot-swappable FC switching modules, MPS multi-protocol IP gateway cards, SSM encryption/replication service modules without chassis power cycleCisco. All MDS 91xx/9250i/93xx are fixed-port with limited or zero expansion slots.
-
Dual redundant Supervisor-1 / Supervisor-2 fabric modules with integrated crossbar switching, stateful failover and non-disruptive ISSU firmware upgrades (fixed switches have single non-replaceable integrated supervisor).
-
Scalable port density: Max 192×4G FC ports when populated with four 48-port DS-X9248-256 line cards, expandable from minimal 12-port base configurations; fixed MDS 9216 only max 30 ports, MDS 9396S/T/V single fixed 96-port ceilingCisco.
-
Native multi-protocol hardware offload via pluggable MPS-14/2 service cards: 2×1G Ethernet for FCIP cross-site SAN extension and iSCSI IP storage gateway (feature built-in only on dedicated service modules, unavailable on base fixed switches).
-
Full FICON mainframe tape/disk acceleration ASIC for IBM enterprise mainframe storage consolidation, a specialized feature missing from most fixed-port MDS switches.
-
Enterprise-grade redundant FRU design: Dual hot-swappable high-wattage power supplies, single 6-fan hot-swappable cooling tray, all field-replaceable units support OIR live replacement without SAN traffic interruptionManualsLib.
-
Unified spare part commonality with MDS 9509/9513 directors (supervisors, power supplies, fan trays, line cards interchangeable) to reduce enterprise maintenance inventory costs.
Core High-Availability Design
All field-replaceable units (FRUs: supervisors, line cards, power supplies, fan tray) support OIR Online Insertion and Removal for live hot-swap maintenance without Fibre Channel data plane interruption. Dual identical 1900W auto-ranging AC power supplies deliver 1+1 N+1 redundant power operation; single integrated hot-swappable six-fan tray provides full chassis cooling, single fan failure triggers alarm but chassis continues operating for 5 minutes for tray replacementManualsLib. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS core directors to reduce control-plane overhead. Dual supervisor modules (Slot5 active, Slot6 standby) maintain full stateful synchronization; automatic failover with zero I/O loss upon active supervisor hardware failureCisco.
Target deployment scenarios: Mid-to-large enterprise multi-building distributed SAN core aggregation, centralized enterprise tape library backup fabric root, large regional mission-critical headquarters cross-site disaster recovery SAN gateway, medium service provider multi-tenant PoP edge storage director, unified campus-wide SAN deployments fully interoperable with MDS 9200 fixed switches and MDS 9509/9513 large modular directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage director base chassis part number prefix
-
9506: MDS 9500 series 6-slot modular director chassis (4 line card slots + 2 supervisor slots)
-
No suffix base chassis = DS-C9506 bare metal frame; complete bundled SKUs like DS-C9506-2K9 include dual Sup-2 + dual AC power supplies
3. Chassis Slot & Hardware Layout Definition
-
Slot Mapping (6 total internal slots on 7RU backplane)
-
Slots 1, 2, 3, 4: Universal hot-swappable line card slots (FC switching modules / MPS multi-protocol service modules / SSM storage service modules)
-
Slots 5, 6: Dedicated redundant supervisor/fabric module slots (only Supervisor-1 / Supervisor-2 fabric cards supported here; Slot5 defaults active, Slot6 standby)Cisco
-
Front Fan Tray: Single integrated hot-swappable multi-fan tray with six variable-speed cooling fans for full chassis airflow
-
Rear Power Compartment: Two independent hot-swappable power supply bays supporting AC or DC high-voltage power modules
-
Out-of-Band Management Interfaces (located on each supervisor module)
-
RJ45 RS232 serial console port for local CLI access
-
Legacy DB-9 RS232 COM terminal port
-
Isolated 10/100BASE-T out-of-band Ethernet management port for remote SSH/Telnet/SNMP administration
-
Onboard compact flash storage partition for SAN-OS firmware images and running configuration archives
-
Front Global Diagnostic LED Bank: Chassis system status, power supply A/B, fan tray, supervisor module, line card port link activity, hardware fault alarm, UID blue locator beacon indicator
-
Airflow Specification: Fixed front-to-back cold air intake (port/fan tray side), hot air exhausted from rear power supply compartment (cold aisle rack standard only; no reversed hot-aisle airflow variant available for MDS 9506)
Supported Transceivers & Pluggable Modules
-
Fibre Channel SFP transceivers (sold separately for all line card FC ports):
-
DS-SFP-FC4G-SW: 4Gbps short-wave multimode, 500m transmission reach
-
DS-SFP-FC4G-LW: 4Gbps long-wave single-mode, 10km transmission reach
-
Backward compatible with legacy 1G / 2G FC SFPs for existing storage array interoperation
-
Supported pluggable line/service modules for Slots 1–4:
-
DS-X9216: 16×4G FC switching module
-
DS-X9232: 32×4G FC high-density switching module
-
DS-X9248-256: 48×4G FC maximum-density line card (4×48-port = 192 total FC ports full chassis)
-
MPS-14/2 Multiprotocol Services Module: 14×2G FC + 2×1G copper GE ports for FCIP / iSCSI gateway
-
SSM Storage Services Module: Inline tape encryption, asynchronous cross-fabric replication, SAN performance analytics
-
Supervisor module compatibility: Supervisor-1 Gen1 fabric module, Supervisor-2 Gen2 upgraded fabric module (higher throughput, larger buffer pools)
-
Power supply compatibility: 1900W AC PEM modules (DS-PWR-1900AC), 1900W DC PEM telecom modules (DS-PWR-1900DC), non-interchangeable between AC/HV chassis variants
4. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Single-chassis non-blocking fabric maximum aggregate bandwidth: 1.024 Tbps full-duplex (fully populated with four 48-port 4G line cards)
-
Wire-speed frame forwarding rate: Up to 1024 Mpps Fibre Channel frame switching at full 4G line rate per port
-
Low-latency virtual output queuing (VOQ) shared packet buffer pool with configurable buffer credit allocation for long-distance ISL trunk links
-
FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
-
Maximum isolated VSAN virtual fabrics: 4094
-
Maximum active zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
-
Jumbo FC frame MTU support: Up to 9000 bytes
-
Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL), NP (NPV edge host aggregation)
-
Link aggregation: PortChannel multi-port FC ISL trunk bundling, maximum 16 FC ports per logical bundle with dynamic load balancing
-
NPV/NPIV native hardware acceleration: Consolidate thousands of server host ports upstream to MDS core directors without core fabric control-plane overhead
-
Native multi-protocol ASIC hardware offload: Full FICON tape/disk processing, FCIP tunnel compression, write acceleration, tape pipelining for cross-site disaster recovery replication
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 1900W PSU fully powers complete chassis independently (1+1 N+1 failover protection)
-
AC input voltage range: 100–240V AC (10% tolerance), 50/60Hz universal auto-ranging alternating current
-
Fan tray: Single integrated hot-swappable six-fan variable-speed assembly; minimum full tray functional to avoid thermal shutdown, single fan failure triggers SNMP fault alert
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; critical thermal alarm threshold at 55°C
-
Typical full-load power draw: 320W fully populated with four 48-port 4G line cards + dual supervisor modules under maximum storage traffic load
-
MTBF: 260,000 hours under standard enterprise data center operating conditions
Physical & Environmental Parameters
-
Rack form factor: 7 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 13.34 cm × 44.45 cm × 57.82 cm (7 rack units, 17.5 × 22.75 inch depth; extended depth 70.37cm with cable management guide installed)
-
Bare chassis weight: 14.1 kg (31 lbs) without power supplies/fan tray/line cards; fully loaded maximum weight 21.3 kg (47 lbs) with dual PSUs, fan tray and four 48-port line cards installed
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access per supervisor: RJ45 RS232 serial port + legacy DB-9 COM terminal port
-
Dedicated isolated 10/100BASE-T out-of-band Ethernet management port per supervisor
-
Onboard flash storage for offline SAN-OS firmware image and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full SAN-OS Multilayer Feature Set (Cisco SAN-OS Release 1.x / 2.x / 3.x)
Layer 2 Fibre Channel Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
-
Dual zoning models: Hard port zoning and soft WWN Smart Zoning for granular host-storage access control
-
Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 2G/4G FC port speeds (max 16-port bundles)
-
DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
-
Local SPAN, RSPAN remote SAN traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass access rack rollouts
Multilayer Storage Routing & Multi-Protocol Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
-
PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
-
Static FC route configuration for controlled inter-VSAN storage data movement
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSAN fabrics
-
FCIP + iSCSI multi-protocol gateway processing via MPS service modules for IP WAN cross-site SAN extension
-
FCIP tunnel hardware acceleration: lossless compression, write acceleration, tape pipelining for long-distance disaster recovery replication
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered classification of storage I/O traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP database workloads, tape backup archives, and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency virtual machine and enterprise database I/O workloads
Enterprise SAN Security Suite
-
Port security: Static WWN locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning with multi-tier administrator access
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
-
VSAN read-only access permissions, port lockdown controls, complete audit logging for all fabric configuration changes
-
Compatibility with MDS SSM encryption and remote replication service modules for data-at-rest tape security
Monitoring & SAN Management Tools
-
Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and reporting
-
Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages
-
Onboard flash storage for SAN-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, I/O latency, frame error counters, SFP optical transmit power diagnostics
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous background hardware health validation without traffic interruption
6. High Availability Capabilities (Core Differentiators vs MDS 9216i-K9 Fixed Modular Switch)
-
Dual redundant Supervisor-1/Supervisor-2 fabric modules with stateful failover and ISSU non-disruptive firmware upgrades (MDS 9216i single integrated supervisor non-hot-swappable)
-
Four universal line card expansion slots supporting up to 192 total FC ports (MDS 9216i only one expansion slot max 30 FC ports)
-
Dedicated integrated crossbar fabric on each supervisor for full non-blocking chassis throughput
-
Dual hot-swappable high-wattage 1900W AC redundant power supplies (MDS 9216i lower-wattage single-redundancy PSUs)
-
Full native FICON mainframe hardware acceleration built into supervisor ASICs (MDS 9216i requires separate service module for limited FICON support)
-
Unified spare part inventory shared with MDS 9509/9513 large directors to reduce enterprise maintenance costs
-
OIR hot-swap support for all major FRUs (supervisors, line cards, power supplies, fan tray) without chassis power cycle
-
Limitation: Legacy 4G Fibre Channel generation hardware only, no native 8G/16G/32G/64G FC support, fixed front-to-back single-direction airflow, legacy SAN-OS firmware stack lacking modern NX-OS automation, EVPN-FC and REST API features, end-of-support since April 30, 2022.
7. Typical Deployment Scenarios
-
Mid-to-Large Virtualized Multi-Building Enterprise Core SAN Director
7RU modular rack form factor deployed as campus central SAN core director; four 48-port 4G line cards populate all line card slots for 192 total FC ports connecting distributed building MDS 92xx edge switches, production all-flash storage arrays and dense blade server racks, dual redundant supervisors provide zero-failover fabric control-plane redundancy, VSAN segmentation isolates independent departmental production, test and backup storage fabrics.
-
Large Regional Mission-Critical Headquarters SAN
Financial, healthcare and government headquarters storage deployments require complete dual power + dual supervisor + redundant line card hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON mainframe support enables long-distance cross-site DR replication via FCIP IP WAN tunnels provisioned on MPS-14/2 multi-protocol expansion modules.
-
Medium Service Provider Multi-Tenant PoP Edge Storage Gateway
VSAN multi-tenant isolation feature logically separates dozens of independent enterprise customer storage fabrics on a single physical MDS 9506 director chassis, scalable high-density 48-port line cards support growing customer port count demand, FCIP gateway modules provide metro WAN inter-PoP storage trunk links between geographically distributed customer sites.
-
Legacy MDS 9200 / MDS 9120 SAN Fabric Consolidation Migration Director
Interoperable bridge director between older 1G/2G fixed MDS edge switches and modern MDS 9500 series core infrastructure, fully backward compatible with legacy 1G/2G FC SFPs while providing scalable 4G high-density port expansion and unified SAN-OS fabric management across mixed-generation MDS hardware fleets.
-
Centralized Enterprise Tape Library Backup Fabric Core
Deployed as dedicated backup SAN aggregation core director, utilizing multi-port ISL PortChannel trunk links to primary production SAN fabrics via FCIP asynchronous off-site tape archive and disaster recovery replication workloads, with unused line card slots reserved for future encryption/replication SSM service module additions as compliance storage requirements expand.
8. Standard Package Contents (Bare Chassis DS-C9506 Base SKU)
1 × DS-C9506 MDS 9506 7RU 6-slot modular SAN director empty chassis (front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included in Bare Chassis DS-C9506)
-
Dual 1900W AC hot-swappable redundant power supply units (DC telecom PSUs sold separately)
-
Single matching hot-swappable six-fan variable-speed fan tray
-
Two redundant Supervisor-1 or Supervisor-2 fabric modules (mandatory for chassis operation)
-
Optional MDS 9000 family pluggable line/service modules (16/32/48-port 4G FC switching modules, MPS-14/2 multi-protocol FCIP/iSCSI gateway module, SSM storage encryption/replication module)
-
DS-SFP-FC4G-SW / DS-SFP-FC4G-LW Fibre Channel SFP optical transceivers for all line card FC ports (backward compatible with 1G/2G FC SFPs)
-
Optional IVR Inter-VSAN Routing multilayer software license, FCIP SAN Extension Enabler license, Mainframe FICON Enabler license
-
RS232 serial console rollover cable, DB-9 legacy COM terminal cable
-
Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9506 is an End-of-Life obsolete 7RU horizontal 6-slot modular Fibre Channel SAN director from the legacy MDS 9500 Series 4G Generation, supplied bare without power supplies, fan trays, supervisor modules and pluggable FC/service line cards (all FRUs sold separately). Built on a 1.024 Tbps non-blocking 4G Fibre Channel fabric backplane with two dedicated redundant supervisor/fabric slots plus four universal hot-swappable line card expansion slots supporting up to 192 total 4G FC ports, fixed front-to-back cold aisle rack airflow, dual hot-swappable 1900W high-wattage AC redundant power supply bays and single six-fan hot-swappable cooling tray with full OIR live FRU replacement support. Running legacy Cisco SAN-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, full FICON mainframe support, multi-protocol FCIP/iSCSI IP SAN extension via pluggable MPS service modules, port zoning, NPV/NPIV edge scaling, hardware-accelerated cross-site replication acceleration and DCNM centralized SAN fabric monitoring. Optimized for mid-to-large enterprise multi-floor core-edge SAN, regional mission-critical disaster recovery storage and medium service provider multi-tenant PoP deployments with complete dual power + dual supervisor hardware redundancy; unique among MDS 92xx fixed switches via fully modular expandable port/service architecture and integrated crossbar fabric supervisors, limited by legacy 4G Fibre Channel generation, single fan tray fault resilience and outdated SAN-OS firmware without modern NX-OS automation or high-speed 8G/16G/32G FC hardware support. Compliant with global safety, EMI, NEBS and RoHS industrial standards, official Cisco hardware support fully terminated April 30, 2022.
|
|
|
| Click:15 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|