|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
71415304616 |
ProductName: |
DS-C9396V-K9 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco MDS 9396V (DS-C9396V-K9) Full Product Description
1. Short Sales Title
Cisco DS-C9396V-K9 2RU High-Density Fixed 64Gbps Multilayer Fibre Channel SAN Fabric Switch, 96 SFP+ FC Ports, Pay-as-you-grow 16-Port Incremental Licensing, Dual Hot-Swap 2000W Platinum AC Redundant Power Supplies, Four Hot-Swap Variable-Speed Fan Trays, Full Non-Blocking 6.144 Tbps Single-Chassis Fabric, Modern Cisco NX-OS 9.x Storage OS, Native FC-NVMe + FEC Forward Error Correction, VSAN, IVR, NPV/NPIV, Hardware Slow Drain Detection, VM I/O Telemetry, Dual Bidirectional Airflow SKUs (Intake/Exhaust), OIR Hot-Swap FRU Design, Current-Generation Hyperscale Virtualized Data Center Core/Edge SAN Switch for All-Flash NVMe Array, AI Database, Virtual Server, Cross-Site Disaster Recovery Tape Backup and MPLS Multi-Tenant Storage Workloads
2. Official Product Overview & Lifecycle
The Cisco DS-C9396V-K9 is the standard AC-powered base SKU of MDS 9396V high-density fixed 64G Fibre Channel multilayer fabric switch in Cisco MDS 9300-V latest-generation series, released May 2025, End-of-Sale TBD, End-of-Support minimum 5 years after EOS announcement. It runs unified NX-OS 9.4(1) and later firmware, fully interoperable with MDS 9200 / MDS 9500 / MDS 9700 modular directors for enterprise and service provider end-to-end SAN fabric managementCisco.
Two airflow variants exist for DS-C9396V-K9:
-
DS-C9396V-48PITK9 (Intake / I): Front-to-back cold aisle airflow (air intake front port panel, exhaust rear PSU compartment)
-
DS-C9396V-48PETK9 (Exhaust / E): Back-to-front hot aisle airflow (air intake rear power panel, exhaust front port panel)
Separate high-voltage DC telecom variant DS-C9396V-HV-K9 sold independently; all power supplies and fan trays are color-coded and non-interchangeable between AC/HV and airflow I/E SKUs.
Core Hardware Differentiators vs MDS 9396T-K9 (32G predecessor)
-
Native 64Gbps Fibre Channel SFP+ auto-sensing (8/16/32/64G), line-rate dedicated bandwidth per port with built-in hardware FEC Forward Error Correction for 64G long-distance links; MDS 9396T limited to maximum 32G FC hardware without native FEC accelerationCisco.
-
Optimized pay-as-you-grow licensing baseline: Ships with48 active ports factory default, expandable via single M9396V-PL16 16-port incremental software licenses to 64 → 80 → full 96 ports without hardware replacement (MDS 9396T also uses 16-port tiers, but lower 32G ASIC performance).
-
Massive 6.144 Tbps single-chassis non-blocking fabric capacity, double MDS 9396T’s 3.072 Tbps throughput, built for NVMe flash, AI database and multi-ISL trunk ultra-high-throughput workloadsCisco.
-
Next-gen dedicated storage ASIC hardware offload: Native FC-NVMe Gen2 processing, VMID virtual machine I/O tracking, built-in real-time SAN telemetry analytics, expanded VOQ virtual output queuing buffers, larger TCAM and buffer credit pools for dense blade server rack deployments.
-
Four independent hot-swappable fan trays with multi-fan fault tolerance (survive up to two fan tray failures without thermal shutdown); improved high-CFM airflow design for 64G high-power SFP+ cooling vs MDS 9396T fans.
-
Heavy-duty 2000W 80 Plus Platinum high-efficiency redundant AC power supplies optimized for full 96×64G populated transceiver power draw (MDS 9396T only 650W PSUs insufficient for full 64G port load).
-
Dual bidirectional airflow hardware options fully compliant with modern cold/hot aisle data center rack containment architectures.
-
Advanced native hardware features: Autozone automatic zoning, enhanced slow-drain detection/isolation, BBSCN buffer credit recovery, full EVPN-FC interoperability, onboard Python 3 interpreter and NX-API REST automation absent from MDS 9396T legacy NX-OS firmwareCisco.
Core High-Availability Design
All field-replaceable units (FRUs: power supplies, fan trays, SFP+ transceivers) support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric traffic interruption. Dual identical 2000W Platinum AC power supplies deliver 1+1 N+1 power redundancy; four separate fan trays eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS 9700 core directors to reduce core fabric control-plane overhead. The supervisor is integrated fixed on chassis backplane and cannot be hot-swapped; chassis power cycle required for supervisor replacement.
Target deployment scenarios: Large virtualized data center core-edge SAN aggregation, multi-building enterprise ultra-high-density departmental storage distribution, large regional mission-critical headquarters cross-site disaster recovery SAN, medium-to-large service provider multi-tenant PoP edge storage gateway, centralized enterprise tape library backup fabric core, and unified campus-wide SAN deployments fully interoperable with MDS 9200/9500/9700 modular directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage switch part number prefix
-
9396V: MDS 9300-V modern 64G high-density fixed fabric series, total 96 integrated SFP+ Fibre Channel ports, V = 64G generation ASIC platform with FEC/NVMe Gen2 hardware acceleration
-
K9: Standard AC power SKU with full multilayer NX-OS enterprise/carrier feature license
-
I = Intake (front-to-back cold aisle airflow), E = Exhaust (back-to-front hot aisle airflow)
3. Chassis Port & Hardware Layout Definition
-
Front Fixed Fibre Channel Ports: 96×hot-swappable SFP+ slots, autosensing 8/16/32/64 Gbps Fibre Channel, every port full non-blocking line-rate bandwidth (mixed host, storage, ISL inter-switch trunk use)
-
Factory default active port set: Only 48 ports licensed and enabled
-
Expand via M9396V-PL16 16-port incremental software licenses to unlock remaining port groups up to full 96-port operation
-
Out-of-Band Management Interfaces
-
RJ45 RS232 serial console port for local CLI access
-
Mini USB dual local console port for laptop zero-cable administration
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports (separate SAN analytics export interface)
-
External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
-
Physical reset button for factory default configuration recovery
-
Front Diagnostic LED Bank: Global system status, power supply A/B, fan tray, FC port link activity, hardware fault alarm, UID blue locator beacon indicator
-
Rear Compartment Layout: Two independent hot-swappable 2000W Platinum AC power supply bays supporting 1+1 N+1 redundant power operation
-
Front lower fan bays: Four separate hot-swappable multi-fan variable-speed fan assemblies
-
Dual Airflow Hardware Options (color-coded PSUs/fans non-interchangeable between I/E chassis):
-
Intake (red): Front-to-back cold air intake at port panel, hot air exhausted from rear power supply compartment (standard cold aisle rack)
-
Exhaust (blue): Back-to-front cold air intake at rear power panel, hot air exhausted from front port panel (hot aisle containment racks)
Supported Transceivers & Power Hardware
-
Fibre Channel SFP+ transceivers (sold separately):
-
DS-SFP-FC64G-SW: 64Gbps short-wave multimode, 500m transmission reach with integrated FEC
-
DS-SFP-FC64G-LW: 64Gbps long-wave single-mode, 10km transmission reach with integrated FEC
-
Backward compatible with legacy 8G / 16G / 32G FC SFPs for existing storage array interoperation
-
Power supply compatibility: C6848V-2000AC 2000W Platinum AC PSUs exclusive to DS-C9396V-K9; high-voltage DC 2000W PSUs manufactured for DS-C9396V-HV-K9 telecom variant, airflow-specific PSUs cannot be mixed between I/E chassis
-
No removable expansion module slot; all FC ports and supervisor hardware integrated on base chassis backplane
4. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Single-chassis non-blocking fabric maximum aggregate bandwidth: 6.144 Tbps full-duplex system-wide bandwidth
-
Wire-speed frame forwarding rate: Up to 6.144 Bpps Fibre Channel frame switching at full 64G line rate
-
Low-latency virtual output queuing (VOQ) shared packet buffer pool with dedicated buffer credit allocation for NVMe flash, AI OLTP database and multi-tenant VPN burst I/O
-
FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
-
Maximum isolated VSAN virtual fabrics: 4094
-
Maximum active zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
-
Jumbo FC frame MTU support: Up to 9000 bytes
-
Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL, NP (NPV edge host aggregation)
-
Link aggregation: PortChannel multi-port FC ISL trunk bundling, maximum 16 FC ports per logical bundle with load balancing
-
NPV/NPIV native feature: Consolidate thousands of server host ports upstream to MDS core directors without core fabric control-plane overhead
-
Slow drain detection hardware ASIC: Automatically isolate slow storage targets to prevent fabric-wide buffer credit starvation storms
-
Native multi-protocol ASIC hardware offload: FC-NVMe Gen2 low-latency frame processing, VMID virtual machine storage I/O tracking, real-time SAN telemetry analytics, built-in FEC Forward Error Correction, BBSCN buffer credit recovery for long-distance ISL linksCisco
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 2000W Platinum AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
-
AC input voltage range: 180–305V 50/60Hz universal auto-ranging alternating current, 80 Plus Platinum high efficiency
-
Fan trays: Four separate hot-swappable multi-fan assemblies; minimum two functional fan trays required to avoid thermal shutdown, up to two fan tray failures tolerated with four-fan full redundancy
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP+ optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; major thermal alarm threshold at 55°C
-
Typical full-load power draw: 650W fully populated with 96×64G SFP+ transceivers under maximum storage traffic load
-
MTBF: 270,000 hours under standard data center and service provider PoP operating conditions
Physical & Environmental Parameters
-
Rack form factor: 2 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 8.64 cm × 44.23 cm × 60.73 cm (3.4 × 17.4 × 23.9 inches)Cisco
-
Bare chassis weight: 11.2 kg (24.7 lbs) without power supplies/fan trays; fully loaded maximum weight 20 kg (44 lbs) with dual PSUs and four populated fan trays installedCisco
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations, FIPS 140-2 Level 2 validatedCisco
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access: RJ45 RS232 serial port + Mini USB console port
-
Dual isolated 10/100/1000BASE-T out-of-band Ethernet management ports
-
External USB flash storage for offline NX-OS image and configuration archives
-
Front panel multi-status LED bank providing real-time hardware health visualization
5. Full NX-OS Multilayer Feature Set (Cisco NX-OS MDS Release 9.x Universal Image)
Layer 2 Fibre Channel Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
-
Dual zoning models: Hard port zoning and soft WWN Smart Zoning + Autozone automatic standalone fabric zoning
-
Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 32G/64G FC port speeds (max 16-port bundles)
-
DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
-
Local SPAN, RSPAN, ESPAN enhanced remote SAN traffic mirroring for multi-session performance troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
-
Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation
-
POAP Power On Auto Provisioning zero-touch switch deployment for mass access rack rollouts
-
VMID virtual machine flow tracking for end-to-end virtual storage I/O visibility
-
FC-NVMe Gen2 optimized frame handling for ultra-low-latency all-flash NVMe storage workloads
-
Hardware FEC Forward Error Correction for reliable long-distance 64G FC ISL links
Multilayer Storage Routing & Multi-Protocol Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
-
PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
-
Static FC route configuration for controlled inter-VSAN storage data movement
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSANs
-
Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
-
PIM-SSM optimized for long-distance disaster recovery storage replication
-
Static FC route redistribution between VSAN and MPLS domains
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered classification of storage I/O traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS templates for production OLTP, NVMe flash storage, tape backup, and disaster recovery replication streams
-
Dedicated high-priority traffic queue for low-latency real-time unified communications and database workloads
-
Medianet media optimization for enterprise video and telepresence storage workflows
Enterprise & Service Provider SAN Security Suite
-
Port security: Static WWN locking to block unauthorized physical server/storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
-
Port lockdown, VSAN read-only access permissions, complete audit logging for all fabric configuration changes
-
FIPS 140-2 validated security compliance for government and financial regulated environments
-
Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
-
IPv6 over Fibre Channel support for modern dual-stack management networks
-
Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering
Monitoring & SAN Management Tools
-
Cisco NDFC / DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and REST API automation
-
Dual isolated out-of-band Ethernet management ports for offline device access during fabric-wide outages and analytics export
-
External USB flash storage for offline NX-OS firmware image upgrades, running configuration backup archives and syslog export
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
-
Onboard Python 3 interpreter + NX-API REST interfaces for custom SAN automation scripts
6. High Availability Capabilities (Core Differentiators vs MDS 9396T-K9 32G Model)
-
Dual hot-swappable high-efficiency 2000W Platinum AC redundant power supplies (1+1 power failover protection, designed for full 96×64G high-power SFP+ load; MDS 9396T only 650W PSUs insufficient for full 64G port population)
-
Four redundant variable-speed hot-swappable fan trays with multi-fan fault tolerance (survive two fan tray failures without SAN outage)
-
Full OIR Online Insertion and Removal support for fan tray, power supplies and SFP+ transceivers; live FRU replacement without chassis power cycle or SAN traffic drop
-
Native 64G full non-blocking per-port Fibre Channel bandwidth with built-in hardware FEC (MDS 9396T limited to maximum 32G line rate, no native FEC offload)
-
Pay-as-you-grow 16-port incremental licensing starting from 48 pre-activated base ports up to full 96 ports, consistent licensing tiers with MDS 9396T but higher generation ASIC performance
-
Dual bidirectional airflow hardware options fully compatible with modern cold/hot aisle data center rack containment architectures
-
Massive 6.144 Tbps single-chassis non-blocking fabric capacity, double MDS 9396T’s 3.072 Tbps bandwidth limit, optimized for high-throughput NVMe and MPLS multi-tenant carrier PoP workloads
-
Modern NX-OS software stack with native EVPN, POAP, Autozone, VMID analytics, onboard Python 3 and REST API automation absent from MDS 9396T legacy firmware
-
Expanded VOQ buffer, TCAM and Flexible NetFlow scale optimized for large-scale virtualized all-flash storage deployments
-
Limitation: Fixed compact 2RU chassis with no modular port card expansion capability like MDS 9500 directors, no native 128G Fibre Channel generation hardware support
7. Typical Deployment Scenarios
-
Large Virtualized Data Center Rack-Scale Edge SAN Switch
Compact 2RU rack form factor deployed as top-of-row / top-of-rack high-density edge SAN aggregation switch; 48 integrated pre-activated 64G FC ports connect primary production NVMe flash storage arrays and dense blade server racks, expandable via 16-port software licenses to full 96 ports as virtualization storage capacity grows, utilizing multi-port ISL PortChannel uplinks to central MDS 9700 core director, creating segmented VSAN production, test and backup storage fabrics for thousands of virtual machines.
-
Large Multi-Building Enterprise Campus Core-Edge SAN Fabric
Multiple DS-C9396V-K9 edge switches deployed per building storage rack, utilizing mixed 32G/64G FC ISL trunk links to campus MDS 9700 core director, forming unified enterprise-wide VSAN-isolated storage fabrics for distributed departmental server and tape backup workloads.
-
Large Regional Mission-Critical Headquarters / Government SAN
Financial, healthcare and government headquarters storage deployments require complete dual power + four-fan hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrated FICON mainframe support enables long-distance cross-site DR replication, while MPLS multi-tenant VSAN isolation features support mixed enterprise and agency storage workloads in a single space-efficient chassis.
-
Medium Service Provider Multi-Tenant PoP Edge Storage Gateway
Native full MPLS/VPLS/EVPN carrier-grade feature set and massive FC address table scale make DS-C9396V-K9 ideal for carrier PoP edge deployments, terminating hundreds of 64G enterprise customer access circuits and high-speed multi-port ISL core backbone trunks with logical VSAN multi-tenant isolation to separate independent customer storage fabrics.
-
Legacy MDS 9396T / MDS 9396S SAN Hardware Refresh Migration Upgrade
Drop-in performance upgrade for aging 32G/16G MDS high-density fixed fabric switches, fully backward compatible with existing 8G/16G/32G Fibre Channel SFP transceivers while unlocking native 64G line-rate bandwidth, hardware FEC acceleration, four-fan fault tolerance, larger fabric throughput capacity and modern NX-OS automation workflows.
8. Standard Package Contents
1 × DS-C9396V-K9 MDS 9396V 2RU high-density fixed Fibre Channel SAN switch base chassis (airflow-neutral frame; fans/PSUs sold separately per intake/exhaust requirement)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included)
-
Dual 2000W Platinum AC hot-swappable redundant power supply units (airflow color-matched I/E variants non-interchangeable)
-
Four matching hot-swappable variable-speed fan trays (airflow color-matched to PSU SKU)
-
M9396V-PL16 16-port incremental software activation licenses to expand active FC port count
-
SFP (8G/16G/32G) / SFP+ (64G) optical fiber transceivers for all base FC ports
-
Optional IVR Inter-VSAN Routing multilayer software license
-
RS232 serial console rollover cable, mini USB console cable
-
USB flash memory sticks for NX-OS image and configuration storage
-
Fibre channel patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9396V-K9 is a current-generation 2RU horizontal high-density fixed Fibre Channel SAN fabric switch from the modern MDS 9100-V 64G Series, supplied bare without power supplies, fan trays and FC SFP/SFP+ transceivers (all FRUs sold separately). Built on a 6.144 Tbps non-blocking 64G Fibre Channel fabric ASIC architecture with 96 autosensing 8/16/32/64G SFP+ ports (all full line-rate no oversubscription), pay-as-you-grow 16-port incremental licensing starting from 48 pre-activated base ports up to full 96 ports, dual hot-swappable 2000W Platinum high-efficiency AC redundant power supply bays and four interchangeable hot-swappable fan modules supporting selectable front-to-back cold aisle or back-to-front hot aisle airflow, with full OIR live FRU replacement support. Running modern Cisco NX-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, FICON mainframe support, port zoning, NPV/NPIV edge scaling, hardware-accelerated FEC forward error correction, slow drain congestion mitigation, native FC-NVMe Gen2 flash storage support, VMID virtual machine I/O tracking, Autozone automatic fabric zoning, FIPS-compliant enterprise security suite and NDFC/DCNM REST API automation. Optimized for large virtualized data center rack-scale edge SAN, multi-building enterprise campus core-edge and MPLS service provider multi-tenant PoP storage deployments with complete dual power + four-fan hardware redundancy; superior to MDS 9396T 32G switches via native 64G line-rate bandwidth, built-in FEC, double 6.144Tbps fabric throughput capacity and higher-capacity 2000W redundant power supplies, limited by fixed chassis design without modular port card expandability and lack of native 128G Fibre Channel generation hardware support. Compliant with global safety, EMI, NEBS and RoHS industrial standards, official Cisco hardware support valid through minimum 5 years post EOL announcement.
|
|
|
| Click:19 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|