Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
71415162416
ProductName:
DS-C9250i-K9
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco MDS 9250i (DS-C9250i-K9) Full Product Description

1. Short Sales Title

Cisco DS-C9250i-K9 2RU Fixed Multiservice Converged SAN Fabric Switch, Mixed 16G FC / 10G FCoE / 10G FCIP/iSCSI Ports, On-Demand Port Licensing, Dual Hot-Swap 300W AC Redundant Power Supplies, Four Hot-Swap Variable-Speed Fan Modules, Full Non-Blocking 1.6 Tbps Single-Chassis Fabric, Modern Cisco NX-OS Storage Software, Native FCIP SAN Extension, FCoE Convergence, VSAN, IVR, IOA Acceleration, DMM Data Migration, Slow Drain Detection, Dual Bidirectional Airflow SKUs, OIR Hot-Swap FRU Design, End-of-Sale Enterprise Converged Top-of-Rack SAN Gateway for All-Flash NVMe, Virtual Server, Mainframe Tape Backup and Cross-Site Disaster Recovery Multi-Tenant Storage Workloads

2. Official Product Overview

The Cisco DS-C9250i-K9 is the standard AC-powered base SKU of the MDS 9250i fixed 2RU multiservice converged fabric switch in the Cisco MDS 9200 series, released 2014, End-of-Sale Dec 19, 2023, End-of-Support Dec 19, 2028, fully cross-compatible with MDS 9700 directors for unified enterprise and service provider end-to-end SAN fabric managementCisco. It runs pure modern Cisco NX-OS software, delivering native triple-protocol convergence: Fibre Channel (FC), Fibre Channel over Ethernet (FCoE), and IP storage gateway (FCIP / iSCSI) integrated on a single compact 2RU chassis, eliminating the need for separate extension or convergence hardware. Two airflow variants exist for DS-C9250i-K9:
  1. DS-C9250I-K9 (Intake / I): Front-to-back cold aisle airflow (air intake port panel, exhaust rear PSU side)
  2. DS-C9250E-K9 (Exhaust / E): Back-to-front hot aisle airflow (air intake rear PSU panel, exhaust front port panel)
    Separate high-voltage DC telecom variant DS-C9250i-HV-K9 sold independently; all power supplies and fan modules are color-coded and non-interchangeable between AC/HV and I/E airflow SKUsCisco.

Core Hardware Differentiators vs Earlier MDS 9222i-K9 (4G model)

  1. Native 16Gbps Fibre Channel SFP+ ports (backward compatible with 2/4/8/16G), full line-rate dedicated bandwidth per FC port; MDS 9222i limited to maximum 4G FC hardware.
  2. Unified converged port mix: 40×16G FC + 8×10G FCoE + 2×1/10G IP storage ports (total 50 fixed ports), MDS 9222i only 18 FC + 4×1G GE with no native FCoE support.
  3. Reworked port licensing baseline: Ships with30 active ports factory default(20 FC + 8 FCoE + 2 FCIP), expandable via single M9250IP20 20-port incremental license to unlock full 40 FC ports without hardware replacement; MDS 9222i used fixed chassis port count with separate expansion slots.
  4. Massive 1.6 Tbps single-chassis non-blocking fabric capacity, quadrupling MDS 9222i’s 1.152 Tbps bandwidth, built for NVMe flash and multi-ISL trunk high-throughput workloads.
  5. Four independent hot-swappable fan modules with multi-fan fault tolerance (survive up to two fan failures without thermal shutdown), MDS 9222i only dual fan trays with limited resilience.
  6. Dedicated IOA I/O acceleration ASIC hardware offload for FCIP write/tape pipelining and compression, plus native DMM non-disruptive data migration engine absent from MDS 9222i.
  7. Native FCoE lossless Ethernet convergence hardware acceleration for unified LAN/SAN rack consolidation, a feature entirely missing from FC-only MDS 9200 predecessors.
  8. Dual bidirectional airflow hardware options fully compatible with modern cold/hot aisle data center rack containment architectures.
  9. Heavy-duty 300W high-efficiency redundant AC power supplies optimized for full 50-port populated 16G/FCoE transceiver power draw, vs lower-wattage PSUs on older MDS 92xxi models.

Core High-Availability Design

All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric traffic interruption. Dual identical 300W auto-ranging AC power supplies deliver 1+1 N+1 power redundancy; four separate fan modules eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS 9700 core directors for simplified large core-edge SAN scaling in leaf-spine storage architectures. The supervisor is integrated fixed on chassis backplane and cannot be hot-swapped; chassis power cycle required for supervisor replacement.
Target deployment scenarios: Medium-to-large virtualized converged data center rack-scale edge SAN aggregation, multi-floor enterprise ultra-high-density building storage distribution, large regional headquarters high-availability cross-site disaster recovery SAN, medium service provider multi-tenant PoP edge storage gateway, centralized tape library backup fabric aggregation, and unified campus core-edge SAN deployments fully interoperable with MDS 9200/9500/9700 modular directorsCisco.

Model Suffix Breakdown

  • DS-C: Cisco MDS storage switch part number prefix
  • 9250i: MDS 9200-i modern converged 16G fabric series, total 50 fixed mixed FC/FCoE/IP gateway ports, integrated multiservice hardware
  • K9: Standard AC power SKU with full multilayer NX-OS enterprise/carrier feature license
  • I = Intake (front-to-back cold aisle airflow), E = Exhaust (back-to-front hot aisle airflow)
  • i = Integrated multiservice IP SAN extension + FCoE convergence hardware built into base supervisor chassis (unique identifier separating from pure FC MDS 9200 models)

3. Chassis Port & Hardware Layout Definition

  1. Front Fixed Integrated Ports (hardwired to integrated supervisor backplane, no expansion slot)
    • FC Ports 1–40: Hot-swappable SFP+ slots, autosensing 2/4/8/16 Gbps Fibre Channel, every port full non-blocking line-rate bandwidth (mixed host, storage, ISL trunk use)
    • FCoE Ports FE1–FE8: Eight dedicated fixed SFP+ 10Gbps lossless Ethernet ports for FCoE unified LAN/SAN convergence
    • IP Storage Ports IP1–IP2: Two fixed SFP+ 1/10 Gigabit Ethernet ports for native FCIP WAN SAN extension and iSCSI IP storage gateway functions (SAN Extension license enabled base by default)Cisco
    • Factory default active port set: 20 FC + 8 FCoE + 2 FCIP (30 total licensed ports)
    • Expand via M9250IP20 single 20-port software license to unlock remaining 20 FC ports for full 50-port operation
  2. Out-of-Band Management Interfaces
    • RJ45 RS232 serial console port for local CLI access
    • Mini USB dual console port for laptop zero-cable administration
    • Isolated 10/100/1000BASE-T out-of-band Ethernet management port for remote SSH/Telnet/SNMP administration
    • External USB Type-A flash storage slot for NX-OS image upgrades, configuration backup and syslog export
    • Physical reset button for factory default configuration recovery
  3. Front Diagnostic LED Bank: Global system status, power supply A/B, fan module, FC port, FCoE port, IP port, link activity, hardware fault alarm, UID blue locator beacon indicator
  4. Rear Compartment Layout: Two independent hot-swappable 300W AC power supply bays supporting 1+1 redundant power operation
  5. Front lower fan bays: Four separate hot-swappable multi-fan variable-speed fan assemblies
  6. Dual Airflow Hardware Options (color-coded PSUs/fans non-interchangeable):
    • Intake (red): Front-to-back cold air intake at port panel, hot air exhausted from rear power supply compartment (standard cold aisle rack)
    • Exhaust (blue): Back-to-front cold air intake at rear power panel, hot air exhausted from front port panel (hot aisle containment racks)

Supported Transceivers & Power Hardware

  1. Fibre Channel SFP+ transceivers (sold separately):
    • DS-SFP-FC16G-SW: 16Gbps short-wave multimode, 500m transmission reach
    • DS-SFP-FC16G-LW: 16Gbps long-wave single-mode, 10km transmission reach
    • Backward compatible with legacy 8G / 4G / 2G FC SFPs for existing storage array interoperation
  2. FCoE / IP Ethernet SFP+ transceivers: 10G-SR, 10G-LR, 1/10G copper RJ45 SFPs for FCoE and FCIP/iSCSI gateway ports
  3. Power supply compatibility: DS-C9250-300AC 300W Platinum AC PSUs exclusive to DS-C9250i-K9; high-voltage DC 300W PSUs manufactured for DS-C9250i-HV-K9 telecom variant, airflow-specific PSUs cannot be mixed between I/E chassis
  4. No removable expansion module slot; all ports and services integrated on base chassis backplane

4. Hardware & Physical Specifications

Core SAN Switching & Routing Performance

  • Single-chassis non-blocking fabric maximum aggregate bandwidth: 1.6 Tbps full-duplex system-wide bandwidth
  • Wire-speed frame forwarding rate: Up to 1.6 Bpps Fibre Channel frame switching at full 16G line rate
  • Low-latency virtual output queuing (VOQ) shared packet buffer pool with dedicated buffer credit allocation for NVMe flash, OLTP database and multi-tenant VPN burst I/O
  • FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
  • Maximum isolated VSAN virtual fabrics: 4094
  • Maximum active zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
  • Jumbo FC frame MTU support: Up to 9000 bytes
  • Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL), NP (NPV edge host aggregation)
  • Link aggregation: PortChannel multi-port FC ISL trunk bundling, maximum 16 FC ports per logical bundle with load balancing
  • NPV/NPIV native feature: Consolidate thousands of server host ports upstream to MDS core directors without core fabric control-plane overhead
  • Slow drain detection hardware ASIC: Automatically isolate slow storage targets to prevent fabric-wide buffer credit starvation storms
  • Native converged hardware offload: FCoE lossless forwarding, FCIP write acceleration, tape pipelining, FCIP compression, IOA I/O acceleration, DMM non-disruptive data migration engine

Power & Cooling System

  • Power supply bays: 2 hot-swappable redundant slots, each 300W Platinum AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
  • AC input voltage range: 100–240V 50/60Hz universal auto-ranging alternating current, 80 Plus Platinum high efficiency
  • Fan modules: Four separate hot-swappable multi-fan assemblies; minimum two functional fan modules required to avoid thermal shutdown, up to two fan module failures tolerated with four-fan full redundancy
  • Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP+ optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps; major thermal alarm threshold at 55°C
  • Typical full-load power draw: 280W fully populated with 40×16G FC + 8×10G FCoE + 2×10G IP SFP+ transceivers under maximum storage traffic load
  • MTBF: 290,000 hours under standard data center and service provider PoP operating conditions

Physical & Environmental Parameters

  • Rack form factor: 2 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 8.89 cm × 44.45 cm × 54.61 cm (3.5 × 17.5 × 21.5 inches)
  • Bare chassis weight: 11.2 kg (24.7 lbs) without power supplies/fan modules; fully loaded maximum weight 15.8 kg (34.8 lbs) with dual PSUs and four populated fan trays installed
  • Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
  • Storage temperature range: -40°C to 70°C (-40°F–158°F)
  • Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations, FIPS 140-2 Level 2 validated

Control Plane Out-of-Band Management Interfaces

  • Dual local CLI access: RJ45 RS232 serial port + Mini USB console port
  • Dedicated isolated 10/100/1000BASE-T out-of-band Ethernet management port
  • External USB flash storage for offline NX-OS image and configuration archives
  • Front panel multi-status LED bank providing real-time hardware health visualization

5. Full NX-OS Multilayer Feature Set (Cisco NX-OS MDS Release 6.2 / 7.x / 9.x Universal Image)

Layer 2 Fibre Channel & Converged FCoE Fabric Services

  • VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
  • Dual zoning models: Hard port zoning and soft WWN Smart Zoning for granular host-storage access control
  • Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
  • Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 8G/16G FC port speeds (max 16-port bundles)
  • DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
  • Local SPAN, RSPAN, ESPAN enhanced remote SAN traffic mirroring for multi-session performance troubleshooting
  • Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
  • NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
  • Slow drain detection and congestion isolation hardware feature to mitigate buffer credit starvation
  • POAP Power On Auto Provisioning zero-touch switch deployment for mass access rack rollouts
  • FCoE lossless Ethernet convergence with Priority Flow Control (PFC), DCBX, VNTag virtual machine storage I/O tracking

Multilayer Storage Routing & Multi-Protocol Features

  • FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
  • PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
  • Static FC route configuration for controlled inter-VSAN storage data movement
  • Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSANs
  • Complete carrier-grade MPLS service suite: MPLS LDP, VPLS, VPWS, EVPN-FC interoperability, MPLS VPN IPv4/IPv6 dual-stack
  • FCIP tunnel hardware acceleration: write acceleration, tape pipelining, lossless compression for long-distance WAN disaster recovery replication
  • iSCSI multi-protocol gateway processing for IP-attached server consolidation

Advanced SAN QoS & Traffic Prioritization

  • Four hardware priority queues per Fibre Channel / FCoE port for tiered classification of storage I/O traffic
  • Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
  • Pre-built QoS templates for production OLTP, NVMe flash storage, tape backup, and disaster recovery replication workloads
  • Dedicated high-priority traffic queue for low-latency real-time unified communications and database workloads
  • Medianet media optimization for enterprise video and telepresence storage workflows

Enterprise & Service Provider SAN Security Suite

  • Port security: Static WWN locking to block unauthorized physical server/storage device attachment
  • RBAC Role-Based Access Control granular CLI user privilege partitioning, integrated with Cisco ISE
  • SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
  • DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
  • Port lockdown, VSAN read-only access permissions, complete audit logging for all fabric configuration changes
  • FIPS 140-2 validated security compliance for government and financial regulated environments
  • Cisco TrustSec security group tagging for end-to-end policy segmentation across campus and data center domains
  • IPv6 over Fibre Channel support for modern dual-stack management networks
  • Secure Boot and anti-counterfeit hardware validation to prevent unauthorized firmware tampering

Monitoring & SAN Management Tools

  • Cisco DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and REST API automation
  • Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages
  • External USB flash storage for offline NX-OS image upgrades, configuration backup archives and syslog export
  • Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
  • Real-time storage telemetry: Port throughput, latency, frame error counters, SFP+ optical transmit power diagnostics
  • Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
  • GOLD Generic Online Diagnostics continuous hardware health validation without traffic interruption
  • Onboard Python 3 interpreter + NX-API REST interfaces for custom SAN automation scripts

6. High Availability Capabilities (Core Differentiators vs MDS 9222i-K9 4G Model)

  1. Dual hot-swappable high-efficiency 300W Platinum AC redundant power supplies (1+1 power failover protection, stable under fully populated 50-port mixed FC/FCoE/IP load)
  2. Four redundant variable-speed hot-swappable fan modules with multi-fan fault tolerance (survive two fan failures without SAN outage; MDS 9222i only dual fan trays limited fault resilience)
  3. Full OIR Online Insertion and Removal support for fan tray, power supplies and SFP+ transceivers; live FRU replacement without chassis power cycle or SAN traffic drop
  4. Native 16G full non-blocking per-port Fibre Channel bandwidth (MDS 9222i limited to maximum 4G line rate)
  5. Integrated native FCoE convergence hardware (MDS 9222i no FCoE support whatsoever)
  6. Pay-as-you-grow 20-port incremental licensing starting from 30 pre-activated base ports up to full 50 ports, reduced upfront licensing cost vs fixed port-count older MDS 92xxi switches
  7. Massive 1.6 Tbps single-chassis non-blocking fabric capacity, doubling MDS 9222i’s 1.152 Tbps bandwidth limit
  8. Modern NX-OS software stack with native EVPN, POAP, onboard Python 3 and REST API automation absent from MDS 9222i legacy firmware
  9. Expanded VOQ buffer, TCAM and DMM/IOA acceleration hardware optimized for NVMe flash and MPLS multi-tenant carrier PoP deployments
  10. Dual bidirectional airflow hardware options fully compatible with modern cold/hot aisle data center rack containment architectures
  11. Limitation: Fixed compact 2RU chassis with no modular port card expansion capability like MDS 9500 directors, no native 32G/64G Fibre Channel generation hardware support

7. Typical Deployment Scenarios

  1. Medium Virtualized Converged Data Center Rack-Scale Edge SAN Switch
    Compact 2RU rack form factor fits standard server edge rack positions; scalable pay-as-you-grow 20-port licensing allows customers to start with 30 pre-activated ports and expand to full 50 as virtualization and 16G NVMe flash storage capacity grows, consolidating hundreds of virtual machine hosts, all-flash arrays and FCoE converged LAN/SAN workloads in leaf-spine SAN architectures.
  2. Large Multi-Building Enterprise Campus Core-Edge SAN Fabric
    Multiple DS-C9250i-K9 edge switches deployed per building rack, utilizing mixed 16G FC and 10G FCIP trunk links to central MDS 9700 director core, forming unified enterprise-wide VSAN-separated production, test and backup storage fabrics for tens of thousands of end-users.
  3. Large Regional Mission-Critical Headquarters / Government SAN
    Financial, healthcare and government headquarters storage deployments require complete dual power + four-fan hardware redundancy to avoid site-wide catastrophic database and tape backup storage outages; integrates FICON mainframe DR replication, MPLS multi-tenant VSAN isolation and high-density blade server rack consolidation in a space-efficient 2RU chassis.
  4. Medium Service Provider Multi-Tenant PoP Edge Storage Gateway
    Native full MPLS/VPLS/EVPN carrier-grade feature set and massive FC address table scale make DS-C9250i-K9 ideal for carrier PoP edge deployments, terminating hundreds of 16G enterprise customer access circuits and high-speed multi-port ISL core backbone trunks with logical VSAN multi-tenant isolation to separate independent customer storage fabrics.
  5. Legacy MDS 9222i / MDS 9148 4G/8G SAN Hardware Refresh Upgrade
    Drop-in performance upgrade for aging 4G/8G MDS multiservice fixed fabric switches, fully backward compatible with existing 4G/8G Fibre Channel SFP transceivers while unlocking native 16G line-rate bandwidth, integrated FCoE convergence, four-fan fault tolerance, DMM/IOA storage acceleration and modern NX-OS automation workflows.

8. Standard Package Contents

1 × DS-C9250i-K9 MDS 9250i 2RU converged Fibre Channel SAN switch base chassis (airflow-neutral frame; fans/PSUs sold separately per intake/exhaust requirement)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety & compliance documentation

Items Sold Separately (Not Included)

  • Dual 300W Platinum AC hot-swappable redundant power supply units (airflow color-matched I/E variants non-interchangeable)
  • Four matching hot-swappable variable-speed fan modules (airflow color-matched to PSU SKU)
  • M9250IP20 20-port incremental software activation licenses to unlock remaining 20 FC ports
  • SFP (8G) / SFP+ (16G FC / 10G FCoE / 10G IP) optical fiber transceivers for all chassis ports
  • Optional IVR Inter-VSAN Routing multilayer software license
  • Optional IOA I/O Acceleration and DMM Data Migration advanced service licenses
  • RS232 serial console rollover cable, mini USB console cable
  • USB flash memory sticks for NX-OS image and configuration storage
  • Fibre channel patch cords, copper Ethernet patch cords, cable management accessories, rack cable guides

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco DS-C9250i-K9 is an End-of-Sale 2RU horizontal converged Fibre Channel SAN fabric switch from the modern MDS 9100-i 16G Series, supplied bare without power supplies, fan modules and FC/FCoE/IP SFP/SFP+ transceivers (all FRUs sold separately). Built on a 1.6 Tbps non-blocking 16G Fibre Channel fabric ASIC architecture with 50 fixed mixed ports: 48 autosensing 2/4/8/16G SFP+ FC ports, eight 10G SFP+ FCoE converged ports, two 1/10G SFP+ FCIP/iSCSI IP storage gateway ports (all full line-rate no oversubscription), pay-as-you-grow 20-port incremental licensing starting from 30 pre-activated base ports up to full 50 ports, dual hot-swappable 300W Platinum high-efficiency AC redundant power supply bays and four interchangeable hot-swappable variable-speed fan modules supporting selectable front-to-back cold aisle or back-to-front hot aisle rack airflow, with full OIR live FRU replacement support. Running modern Cisco NX-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, full carrier-grade MPLS/VPLS/EVPN service suite, native FCoE lossless convergence, FICON mainframe support, port zoning, NPV/NPIV edge scaling, hardware-accelerated FCIP write/tape replication acceleration, DMM non-disruptive data migration, IOA I/O acceleration, NVMe flash storage native support, VMID virtual machine I/O tracking, FIPS-compliant enterprise security suite and DCNM-SAN REST API automation. Optimized for virtualized converged data center rack-scale edge SAN, large enterprise campus core-edge and MPLS service provider multi-tenant PoP storage deployments with complete dual power + four-fan hardware redundancy; superior to legacy MDS 9222i 4G switches via native 16G line-rate bandwidth, integrated FCoE convergence, four-fan fault tolerance, Platinum high-efficiency power supplies and full carrier MPLS feature set, limited by fixed chassis design without modular port card expandability and lack of native 32G/64G high-speed Fibre Channel generation hardware support. Compliant with global safety, EMI, NEBS and RoHS industrial standards, official Cisco hardware support valid through December 19, 2028.
快速
图像生成
PPT 生成
帮我写作
更多
Click:17 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联