|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
7141513216 |
ProductName: |
DS-C9216A-K9 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco MDS 9216A (DS-C9132T-K9 typo correction: DS-C9216A-K9) Full Product Description
1. Short Sales Title
Cisco DS-C9216A-K9 3RU Semi-Modular Multilayer Fibre Channel SAN Fabric Switch, 16 Integrated 1/2/4G FC SFP Ports + Single Universal Hot-Swap Expansion Module Slot, Dual Hot-Swap 845W AC Redundant Power Supplies, Dual Hot-Swap Fan Trays, Upgradable 1.024 Tbps Non-Blocking Fabric, SAN-OS Dual-Stack Software, Multi-Protocol FCIP/iSCSI/FICON, VSAN, IVR, NPV, OIR Hot-Swap FRU Design, End-of-Life Upgraded Mid-Size Enterprise Modular SAN Aggregation Switch for Multi-Floor Server, Flash Disk, Tape Backup and Cross-Site Disaster Recovery Storage Workloads
2. Official Product Overview
The Cisco DS-C9216A-K9 is the updated second-generation AC-powered base SKU of the MDS 9216A semi-modular multilayer Fibre Channel fabric switch in the Cisco MDS 9200 series, released 2006, End-of-Sale Aug 22, 2009, Last Day of Hardware Support Aug 21, 2014, fully obsolete with no active Cisco TAC engineering supportCisco. It runs dual-image SAN-OS software, fully cross-compatible with MDS 9500 series directors for unified enterprise SAN fabric management. DS-C9216A-K9 is the hardware refresh successor to the original DS-C9216-K9 first-generation chassis.
Core Hardware Differentiators vs Original DS-C9216-K9
-
Expanded module compatibility: Supports all MDS 9000 family service/port modules including 32-port high-density FC switching modules, SSM storage encryption/replication modules, and MPS-14/2 multi-protocol IP gateway cards (original MDS 9216 limited early module compatibility only)ManualsLib.
-
Higher maximum aggregate fabric capacity: Up to 1.024 Tbps full-duplex bandwidth when populated with high-density expansion modules, versus 512 Gbps hard cap on DS-C9126-K9 base hardwareCisco.
-
Improved supervisor ASIC with native 4Gbps Fibre Channel auto-sensing support (original MDS 9216 only 1G/2G baseline) and enhanced buffer credit allocation to mitigate slow-drain congestion.
-
Dual hot-swappable fan tray design (two independent fan assemblies) vs single fan tray on legacy MDS 9216, providing multi-fan fault tolerance (survive one fan tray failure without thermal shutdown).
-
Optimized power subsystem with refined load balancing logic for fully populated high-port expansion module deployments, reducing thermal stress under full traffic load.
-
Unified spare part commonality with MDS 9500 directors; all power supplies, fan trays and service modules are interchangeable across MDS 9216A / MDS 9500 product lines to lower inventory costsManualsLib.
Core High-Availability Design
All field-replaceable units (FRUs) support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric traffic interruption. Dual identical 845W auto-ranging AC power supplies deliver 1+1 N+1 power redundancy; dual independent hot-swappable fan trays eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to prevent fabric-wide RSCN broadcast storms. Built-in NPV/NPIV edge switch mode offloads thousands of blade server host N_Port registrations to upstream MDS 9500 core directors for simplified large core-edge SAN scaling. Integrated supervisor is fixed on chassis backplane and cannot be hot-swapped; chassis power cycle required for supervisor replacement.
Target deployment scenarios: Mid-to-large virtualized multi-floor enterprise building distributed SAN aggregation, centralized enterprise tape library backup fabric core, large regional headquarters high-availability cross-site disaster recovery SAN, medium service provider multi-tenant PoP edge storage gateway, and unified campus core-edge SAN deployments fully interoperable with MDS 9500 modular directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage switch part number prefix
-
9216A: MDS 9200 second-generation semi-modular fabric series, 16 integrated base FC ports + one universal expansion slot, upgraded ASIC and fan architecture
-
K9: Standard AC power SKU with full multilayer SAN enterprise feature license (HV DC telecom variant DS-C9216A-HV-K9 sold separately; power supplies and fan trays are color-coded and non-interchangeable between AC/HV airflow variants)
Chassis Port & Hardware Layout Definition
-
Front Base Fixed Fibre Channel Ports: 16×hot-swappable SFP slots, autosensing 1/2/4 Gbps Fibre Channel, all ports full non-blocking line-rate bandwidth
-
Ports 1–16: Hardwired integrated base FC ports on chassis backplane
-
Front Universal Expansion Bay: Single empty hot-swappable module slot for MDS 9000 family service/port hardware:
-
MPS-14/2 Multiprotocol Services Module: 14×FC SFP ports + 2×1G Ethernet ports for FCIP / iSCSI IP SAN extension gateways
-
DS-X9232-256 32-port high-density 4G FC switching module to scale total fabric port count
-
SSM Storage Services Module for inline tape/media encryption and asynchronous cross-fabric replication
-
Out-of-Band Management Interfaces
-
RJ45 RS232 serial console port for local CLI access
-
Legacy DB-9 COM terminal port for industrial terminal equipment connectivity
-
Isolated 10/100BASE-T Ethernet out-of-band management port for remote SSH/Telnet/SNMP administration
-
Onboard flash storage partition for SAN-OS firmware images and running configuration archives
-
Front Diagnostic LED Bank: Global system status, power supply A/B, fan tray, base FC port, expansion module port, link activity, hardware fault alarm, UID blue locator beacon indicator
-
Rear Compartment Layout: Dual independent hot-swappable 845W AC power supply bays supporting 1+1 redundant power operation
-
Front lower fan tray bays: Two separate hot-swappable multi-fan variable-speed fan assemblies
-
Airflow Specification: Fixed front-to-back cold air intake at port panel, hot air exhausted from rear power supply compartment (cold aisle rack standard only, no reversed hot-aisle airflow hardware variant)
Supported Transceivers & Expansion Hardware
-
Fibre Channel SFP transceivers (sold separately):
-
DS-SFP-FC4G-SW: 4Gbps short-wave multimode, 500m transmission reach
-
DS-SFP-FC4G-LW: 4Gbps long-wave single-mode, 10km transmission reach
-
Backward compatible with legacy 1G / 2G FC SFPs for existing storage array interoperation
-
Expansion module compatibility: All MDS 9000 family port and multi-protocol service modules interchangeable with MDS 9500 directors
-
Power supply compatibility: 845W AC PSUs exclusive to DS-C9216A-K9; high-voltage DC 845W PSUs manufactured for DS-C9216A-HV-K9 telecom variant, airflow-specific hardware cannot be mixed between SKUs
-
No native built-in Ethernet downlink ports; all IP storage gateway functionality dependent on pluggable MPS service expansion modules
3. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Single-chassis non-blocking fabric maximum aggregate bandwidth: 1.024 Tbps full-duplex (with high-density 32-port expansion module populated)
-
Wire-speed frame forwarding rate: Up to 1024 Mpps Fibre Channel frame switching at full 4G line rate
-
Low-latency dynamic shared packet buffer pool with enhanced buffer credit management to mitigate slow-drain storage congestion
-
FC N_Port address table capacity: 1,048,576 unique host identifiers, optimized for dense blade server rack deployments
-
Maximum isolated VSAN virtual fabrics: 4094
-
Maximum active fabric zone sets: 256 zone sets, up to 2000 individual zone entries per VSAN
-
Jumbo Fibre Channel frame MTU support: Up to 9000 bytes
-
Supported FC port operating modes: F (Fabric host), FL (Arbitrated Loop), TL (Extended Loop), E (ISL inter-switch trunk), TE (Extended ISL), NP (NPV edge host aggregation)
-
Link aggregation: PortChannel multi-port ISL trunk bundling, maximum 8 FC ports per logical bundle with load balancing
-
NPV/NPIV native hardware acceleration: Consolidate thousands of rack server host ports upstream to MDS core directors without core fabric control-plane overhead
-
Full FICON protocol hardware offload for IBM enterprise mainframe disk and tape storage connectivity
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 845W AC PSU fully powers complete chassis independently (1+1 N+1 failover protection)
-
AC input voltage range: 100–240V 50/60Hz universal auto-ranging alternating current
-
Fan trays: Two separate hot-swappable multi-fan assemblies; minimum two functional fan trays required to avoid thermal shutdown, single fan tray failure triggers SNMP fault alert without SAN traffic interruption
-
Real-time telemetry monitoring: Fan rotational speed, internal chassis ambient temperature, PSU input/output voltage, SFP/X2 optical transmit power, port error counters and module fault logging via console syslog and SNMP v1/v2c/v3 traps
-
Typical full-load power draw: 210W fully populated with 16×4G SFPs + MPS-14/2 multi-protocol expansion module under maximum storage traffic load
Physical & Environmental Parameters
-
Rack form factor: 3 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 13.34 cm × 44.45 cm × 57.82 cm (5.25 × 17.5 × 22.75 inches; extended depth 70.37cm with cable management guide installed)
-
Bare chassis weight: 14.1 kg (31 lbs) without power supplies and fan trays; fully loaded maximum weight 20.4 kg (45 lbs) with dual PSUs, dual fan trays and populated expansion service module
-
Operating ambient temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 2000 meters
-
Storage temperature range: -40°C to 70°C (-40°F–158°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant per regional environmental regulations
Control Plane Out-of-Band Management Interfaces
-
Dual local CLI access: RJ45 RS232 serial console port + legacy DB-9 COM terminal port
-
Dedicated isolated 10/100BASE-T out-of-band Ethernet management port for remote fabric administration
-
Front panel multi-status LED bank providing real-time hardware health visualization
4. Full SAN-OS Multilayer Feature Set (Cisco SAN-OS MDS Release 2.x / 3.x)
Layer 2 Fibre Channel Switching & Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric segmentation for multi-application / multi-tenant storage environment isolation
-
Dual zoning models: Hard port zoning and soft WWN zoning for granular host-storage access control
-
Complete FICON protocol stack support for IBM mainframe disk and tape enterprise storage connectivity
-
Inter-Switch Link (ISL) trunk PortChannel load balancing across mixed 1G/2G/4G FC port speeds
-
DTP Fibre Channel trunk negotiation protocol, FSPF dynamic fabric domain ID routing
-
Local SPAN, RSPAN remote SAN traffic mirroring for storage performance and fault troubleshooting
-
Per-port broadcast/multicast storm suppression to eliminate fabric-wide RSCN broadcast outages
-
NPV N_Port Virtualizer edge switch mode for large-scale core-edge enterprise SAN architecture deployment
Multilayer Storage Routing & Multicast Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch distributed SAN topologies
-
PIM-SM IP multicast for cross-fabric asynchronous synchronous backup replication traffic
-
Static FC route configuration for controlled inter-VSAN storage data movement
-
Licensed IVR Inter-VSAN Routing feature for secure data transfer between isolated VSAN fabrics
-
FCIP and iSCSI multi-protocol gateway processing via MPS expansion service modules for IP WAN cross-site SAN extension
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered classification of storage I/O traffic
-
Ingress frame policing and egress bandwidth shaping to throttle low-priority tape backup and replication streams
-
Pre-built QoS policy templates for production OLTP database workloads, tape backup archives and disaster recovery replication
-
Dedicated high-priority traffic queue for low-latency virtual machine and enterprise database I/O workloads
Enterprise SAN Security Suite
-
Port security: Static WWN locking to block unauthorized physical server and storage device attachment
-
RBAC Role-Based Access Control granular CLI user privilege partitioning with multi-tier administrator access
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, AES encrypted startup configuration files
-
DH-CHAP mutual bidirectional authentication for ISL inter-switch link fabric authentication
-
VSAN read-only access permissions, port lockdown controls, complete audit logging for all fabric configuration changes
-
Compatibility with MDS SSM encryption and remote replication service modules for data-at-rest tape security
Monitoring & SAN Management Tools
-
Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring, provisioning and reporting
-
Isolated out-of-band Ethernet management port for offline device access during fabric-wide outages
-
Onboard flash storage partition for SAN-OS firmware image upgrades and running configuration backup archives
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, I/O latency, frame error counters, SFP optical transmit power diagnostics
-
Event notification via email, syslog and SNMP traps for real-time fabric fault alerting
-
GOLD Generic Online Diagnostics continuous background hardware health validation without traffic interruption
5. High Availability Capabilities (Core Differentiators vs Original DS-C9216-K9)
-
Dual hot-swappable high-wattage 845W AC redundant power supplies (1+1 power failover protection, stable under fully populated high-density expansion module load)
-
Dual independent hot-swappable fan trays with multi-fan fault tolerance (survive one fan tray failure without SAN traffic outage; MDS 9216 only single fan tray limited fault resilience)
-
Full OIR Online Insertion and Removal support for fan trays, power supplies and FC SFP transceivers; live FRU replacement without chassis power cycle or SAN traffic drop
-
Native 4Gbps auto-sensing FC port hardware (original MDS 9216 limited to maximum 2G line rate)
-
Universal expansion slot compatible with all modern MDS 9000 family port and multi-protocol service modules (original MDS 9216 restricted to early-generation modules only)
-
Upgraded ASIC buffer credit management with native slow-drain detection to mitigate fabric-wide congestion starvation
-
Higher single-chassis non-blocking fabric bandwidth (1.024 Tbps vs 512 Gbps hard cap on MDS 9216)
-
Unified spare part inventory shared with MDS 9500 directors to reduce enterprise hardware maintenance costs
-
Limitation: Legacy SAN-OS software stack without modern NX-OS automation APIs, EVPN-FC interoperability and REST API support; fixed front-to-back cold aisle airflow only, no modular supervisor upgrade capability, no native 8G/16G/32G Fibre Channel generation hardware support
6. Typical Deployment Scenarios
-
Mid-to-Large Enterprise Multi-Floor Building Distribution SAN Aggregation Switch
3RU rack modular form factor deployed as departmental building core SAN switch; 16 integrated base 4G FC ports connect primary production disk storage arrays, MPS-14/2 expansion module adds additional host ports and FCIP inter-building trunk links to central MDS 9500 core director, creating segmented VSAN production, test and backup storage fabrics.
-
Large Regional Mission-Critical Headquarters SAN
Financial, healthcare and government headquarters storage deployments require complete dual power + dual fan hardware redundancy to avoid catastrophic database and tape backup storage outages; integrated FICON mainframe support enables long-distance cross-site DR replication via FCIP IP WAN extension.
-
Medium Service Provider Multi-Tenant PoP Edge Storage Gateway
VSAN isolation feature logically separates dozens of independent enterprise customer storage environments on a single physical MDS 9216A modular switch, reducing capital hardware TCO for medium carrier PoP edge storage workloads with expandable high-density port capacity for growing customer base.
-
Legacy MDS 9216 SAN Hardware Refresh Migration Upgrade
Drop-in performance upgrade for aging first-generation MDS 9216 fixed fabric switches, fully backward compatible with existing 1G/2G Fibre Channel SFP transceivers while unlocking native 4G line-rate bandwidth, dual-fan fault tolerance, universal expansion module compatibility and larger fabric throughput capacity.
-
Centralized Enterprise Tape Library Backup Fabric Core
Deployed as dedicated backup SAN aggregation core switch, utilizing high-speed multi-port ISL PortChannel trunk links to primary production SAN fabrics via FCIP IP extension for asynchronous off-site tape archive and disaster recovery replication workloads.
7. Standard Package Contents
1 × DS-C9216A-K9 MDS 9216A 3RU semi-modular Fibre Channel SAN switch base chassis (fixed front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety compliance documentation
Items Sold Separately (Not Included)
-
Dual 845W AC hot-swappable redundant power supply units (airflow color-matched hardware non-interchangeable with HV telecom variants)
-
Dual matching hot-swappable variable-speed fan trays
-
Optional MDS 9000 family pluggable expansion modules (MPS-14/2 multi-protocol gateway, DS-X9232 32-port FC switching module, SSM storage encryption/replication module)
-
DS-SFP-FC4G-SW / DS-SFP-FC4G-LW Fibre Channel SFP optical transceivers for all base and expansion module FC ports (backward compatible with 1G/2G FC SFPs)
-
Optional IVR Inter-VSAN Routing multilayer software license
-
RS232 serial console rollover cable, DB-9 legacy COM terminal cable
-
Fibre channel patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9216A-K9 is an End-of-Life obsolete 3RU horizontal semi-modular Fibre Channel SAN fabric switch from the second-generation MDS 9200 Series, supplied bare without power supplies, fan trays and pluggable expansion service modules (all FRUs sold separately). Built on a 1.024 Tbps non-blocking 4G Fibre Channel fabric ASIC architecture with 16 integrated autosensing 1/2/4G FC SFP base ports plus one universal hot-swappable expansion slot supporting all MDS 9000 port/multi-protocol service modules, fixed front-to-back cold aisle rack airflow, dual hot-swappable 845W high-wattage AC redundant power supply bays and dual interchangeable hot-swappable fan trays with full OIR live FRU replacement support. Running legacy Cisco SAN-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, FICON mainframe support, port zoning, NPV/NPIV edge scaling, FCIP/iSCSI IP SAN extension and DCNM centralized SAN monitoring. Optimized for mid-to-large enterprise multi-floor distribution SAN, large campus core-edge and medium carrier multi-tenant PoP storage deployments with complete dual power + dual-fan hardware redundancy; superior to original MDS 9216-K9 first-generation switches via native 4G line-rate bandwidth, dual-fan fault tolerance, universal expansion module compatibility and larger fabric throughput capacity, limited by legacy SAN-OS feature stack without modern NX-OS automation, fixed single-direction airflow and lack of native 8G/16G/32G high-speed Fibre Channel generation hardware support. Compliant with global safety, EMI, NEBS and RoHS industrial standards, fully out of Cisco TAC hardware support since August 21, 2014.
|
|
|
| Click:18 Entry Time:2026-07-14 【Print】 【Close】 |
|
|
|
|