Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
71414175916
ProductName:
DS-C9140-K9
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco MDS 9140 (DS-C9140-K9) Full Product Description

1. Short Sales Title

Cisco DS-C9140-K9 1RU Fixed 40-Port 1/2Gbps Multilayer Fibre Channel SAN Fabric Switch, 8 Full-Rate Target Ports + 32 Oversubscribed Host-Optimized FC SFP Ports, Dual Hot-Swap 300W AC Redundant Power Supplies, Dual Hot-Swap Fan Modules, Shared Bus Backplane Up to 80 Gbps Aggregate Bandwidth, SAN-OS Multilayer Storage Software, VSAN Isolation, FICON Mainframe Support, OIR Hot-Swap FRU Design, End-of-Sale Flagship High-Density Edge SAN Switch for Enterprise Mass Server, Disk Array, Tape Library and Multi-Site Consolidated Storage Workloads

2. Official Product Overview

The Cisco DS-C9140-K9 is the standard AC-powered base SKU of the MDS 9140 fixed 1RU multilayer Fibre Channel fabric switch in the Cisco MDS 9100 storage switch family, released early 2000s, End-of-Sale Oct 9, 2008, End-of-Support Oct 10, 2013, fully obsolete with no active Cisco TAC engineering supportCisco. It runs unified Cisco SAN-OS software shared with MDS 9200/9500 modular directors, delivering consistent end-to-end enterprise SAN fabric management for high-density edge storage area networks.

Core Hardware Differentiators vs Smaller MDS 9120 / MDS 9124

  1. Maximum port count of all original non-T MDS 9100 fixed chassis: Total 40 autosensing 1/2G FC SFP ports, split into 8 dedicated full-rate target ports and 32 oversubscribed host ports, double the port density of MDS 9120 (20 ports) and higher than MDS 9124 (24 ports)Cisco.
  2. Port performance tier design: 8 target ports with maximum buffer credits for high-performance disk/tape storage arrays and ISL backbone links; 32 host ports optimized for server attach with reduced buffer allocation to balance cost and density.
  3. Dual 300W high-wattage redundant AC power supplies (MDS 9120 only uses 300W as well, but MDS 9124 lower power rating), supporting full 40-port populated load without power bottlenecks.
  4. Dual independent hot-swappable fan modules for redundant cooling, single fan failure does not trigger SAN shutdown, no mandatory fan upgrade for basic SAN-OS operation.
  5. Fixed front-to-back airflow for standard cold aisle rack containment, no reversed hot-aisle airflow variant available for this model.
  6. Unified interoperability with all MDS 9500 core directors for building large multi-building campus SAN fabrics, supporting VSAN, IVR, FICON and zoning identical to larger modular directors.

Core High-Availability Design

All FRUs support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric outage. Dual identical 300W AC power supplies provide 1+1 power redundancy; dual separate fan modules eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to avoid fabric-wide broadcast storms. NPV edge mode offloads host registration to upstream MDS 9500 directors for simplified ultra-high-density rack-scale edge SAN scaling. Single-supervisor architecture (integrated control plane on chassis backplane) simplifies edge deployment with no standby supervisor licensing cost.
Target deployment scenarios: Ultra-high-density multi-floor building distribution SAN, large regional headquarters high-availability disaster recovery SAN, medium service provider multi-tenant PoP edge, centralized enterprise tape library backup fabric aggregation, and mid/large data center rack edge storage consolidation interoperable with MDS 9200/9500 core directors.

Model Suffix Breakdown

  • DS-C: Cisco MDS storage switch part number prefix
  • 9140: MDS 9100 fixed fabric series, total 40 autosensing Fibre Channel SFP ports split into target/host tiers
  • K9: Standard AC power SKU with full multilayer SAN feature license (DS-C9140-HV-K9 is separate high-voltage DC telecom variant; PSUs/fans non-interchangeable between AC/HV SKUs)

Chassis Port & Hardware Layout Definition

  1. Front Panel Fibre Channel Ports: 40×hot-swappable SFP slots, autosensing 1Gbps / 2Gbps Fibre Channel
    • Ports 1–8: Full-rate target-optimized ports (max buffer credits, no oversubscription, for high-performance storage arrays, tape libraries, ISL inter-switch backbone links)
    • Ports 9–40: Host-optimized oversubscribed ports for physical servers, blade servers, virtualization host SAN attach
  2. Out-of-Band Management Interfaces:
    • RJ45 RS232 serial console port for local CLI access
    • Isolated 10/100BASE-T Ethernet out-of-band management port for remote SSH/Telnet/SNMP access
    • Physical reset button for factory default configuration recovery
  3. Front Diagnostic LED Bank: Global system status, power supply A/B, fan module, port link/activity, fault alarm, UID blue beacon indicator
  4. Rear Compartment Layout: Dual independent hot-swappable 300W AC power supply bays supporting 1+1 N+1 power redundancy
  5. Front lower fan bays: Dual separate hot-swappable multi-fan modules (two independent fan assemblies for redundant cooling)
  6. Airflow Specification: Fixed front-to-back cold air intake at port panel, hot air exhausted from rear power supply compartment (cold aisle standard only, no reversed airflow hardware option)

Supported Transceivers & Power Options

  1. Fibre Channel SFP transceivers (sold separately):
    • DS-SFP-FC-2G-SW: 2Gbps short-wave multimode, 500m reach
    • DS-SFP-FC-2G-LW: 2Gbps long-wave single-mode, 10km reach
    • Backward compatible with 1G FC SFPs for legacy storage interoperation
  2. Power supply compatibility: Only 300W AC PSUs supported for DS-C9140-K9; HV DC 3000W PSUs exclusive to DS-C9140-HV-K9 variant, non-interchangeable hardware
  3. No Ethernet downlink ports; purpose-built exclusively for Fibre Channel block storage SAN workloads

3. Hardware & Physical Specifications

Core SAN Switching & Routing Performance

  • Total passive shared bus backplane capacity: Max 80 Gbps full-duplex aggregate bandwidth
  • Wire-speed forwarding rate: Up to 80 Mpps Fibre Channel frame switching, limited by shared bus architecture
  • Dynamic shared packet buffer pool; 255 buffer credits per full-rate target port, 12 buffer credits per oversubscribed host portCisco
  • FC address table capacity: 1,048,576 N_Port identifiers for massive blade server rack deployments
  • Maximum VSANs: 4094 isolated virtual storage fabrics
  • Maximum active zone sets: 256 zone sets, up to 2000 zones per fabric
  • Jumbo FC frame MTU support: Up to 9000 bytes
  • Port modes supported: F (Fabric host), FL (Loop), TL (Extended Loop), E (ISL), TE (Extended ISL), NP (NPV edge host)
  • Link aggregation: PortChannel for multi-port ISL trunking, maximum 8 FC ports per logical bundle
  • NPV/NPIV native feature: Consolidate hundreds of host ports upstream to MDS core directors without core fabric overhead

Power & Cooling System

  • Power supply bays: 2 hot-swappable redundant slots, each 300W AC PSU fully powers full chassis independently (1+1 N+1 failover protection)
  • AC input voltage range: 100–240V 50/60Hz universal auto-ranging AC
  • Fan modules: Two separate hot-swappable multi-fan assemblies; single fan module failure triggers SNMP alert without SAN traffic outage, minimum two functional fan modules required to avoid thermal shutdown
  • Airflow direction: Fixed front-to-back cold aisle intake, rear hot exhaust
  • Real-time monitoring: Fan RPM, internal chassis temperature, PSU voltage, SFP optical power, port and module fault logging via console syslog and SNMP v1/v2c/v3 traps

Physical & Environmental Parameters

  • Rack form factor: 1 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 4.45 cm × 43.69 cm × 58.67 cm (1.75 × 17.2 × 23.1 inches; extended depth 71.37cm with cable management guide)Cisco
  • Bare chassis weight: 10.89 kg (24 lbs) without power supplies/fan modules; fully loaded max weight 11.34 kg (25 lbs) with dual PSUs and dual fan trays installedCisco
  • Operating temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 3000 meters
  • Storage temperature range: -40°C to 75°C (-40°F–167°F)
  • Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant

Control Plane Out-of-Band Management Interfaces

  • RJ45 RS232 serial console port for local CLI access
  • Dedicated isolated 10/100BASE-T out-of-band Ethernet management port
  • Front panel multi-status LED bank for real-time hardware health visibility

4. Full SAN-OS Multilayer Feature Set (Cisco SAN-OS Release 2.x / 3.x)

Layer 2 Fibre Channel Switching & Fabric Services

  • VSAN Virtual Storage Area Network: Logical fabric isolation for multi-application/multi-tenant storage segmentation
  • Hard port zoning + soft WWN zoning for granular host-storage access control
  • Full FICON protocol support for IBM mainframe disk/tape storage connectivity
  • Inter-Switch Link (ISL) trunking, PortChannel load balancing across multiple FC ports
  • DTP Fibre Channel trunk negotiation, FSPF fabric dynamic domain ID routing
  • Local SPAN, RSPAN remote SAN traffic mirroring for storage performance troubleshooting
  • Broadcast/multicast storm suppression per FC port to eliminate fabric flooding outages
  • NPV N_Port Virtualizer edge switch mode for large core-edge SAN scaling

Multilayer Storage Routing & Multicast Features

  • FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch SAN topologies
  • PIM-SM IP multicast for cross-fabric backup replication traffic
  • Static FC route configuration for cross-VSAN inter-fabric connectivity
  • Licensed IVR Inter-VSAN Routing feature for controlled data movement between isolated VSANs

Advanced SAN QoS & Traffic Prioritization

  • Four hardware priority queues per Fibre Channel port for tiered storage traffic classification
  • Ingress frame policing, egress bandwidth shaping to throttle low-priority backup/replication streams
  • Pre-built QoS templates for production OLTP, tape backup, and disaster recovery replication streams
  • Dedicated high-priority queue for low-latency database and virtualization I/O workloads

Enterprise SAN Security Suite

  • Port security: Static WWN locking to block unauthorized server/storage device attach
  • RBAC Role-Based Access Control granular CLI user privilege partitioning
  • SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, encrypted startup configuration files
  • DH-CHAP mutual authentication for ISL inter-switch link fabric authentication
  • Port lockdown, VSAN read-only access permissions, full audit logging for all fabric configuration changes
  • Compatible with external MDS SSM encryption and replication service modules

Monitoring & SAN Management Tools

  • Cisco Fabric Manager centralized graphical SAN fabric monitoring and provisioning
  • Isolated out-of-band Ethernet management port for offline device access during fabric outages
  • Onboard flash storage for SAN-OS image upgrades and configuration backup archives
  • Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
  • Real-time storage telemetry: Port throughput, latency, frame error counters, SFP optical power diagnostics
  • Event notification via email, syslog and SNMP traps for fabric fault alerting

5. High Availability Capabilities (Core Differentiators vs MDS 9120-K9 / MDS 9124-K9)

  1. Dual hot-swappable high-wattage 300W AC power supplies (1+1 power failover, single PSU fully operational under full 40-port load)
  2. Dual independent hot-swappable fan modules with individual fault detection and real-time SNMP fault alerting
  3. Full OIR Online Insertion and Removal support for fan modules, power supplies and SFP transceivers; live FRU replacement without chassis power shutdown or SAN traffic drop
  4. 40 total FC ports (8 full-rate target + 32 host ports) – maximum port density of all non-T MDS 9100 fixed chassis, double MDS 9120 and higher than MDS 9124
  5. Optimized buffer credit allocation for mixed storage/host workloads, ideal for balanced enterprise production + backup SAN environments
  6. NPV edge switch mode simplifies large core-edge enterprise SAN architecture deployments
  7. VSAN fabric isolation limits fault domains to single virtual storage segment, preventing fabric-wide broadcast storms
  8. FSPF dynamic routing automatic failover to alternate ISL paths with sub-second convergence
  9. Limitation: Fixed oversubscribed host port architecture creates bandwidth bottlenecks for all-storage deployments; no modular port card expandability like MDS 9200/9500 directors, no native 4G/16G/32G FC generation support

6. Typical Deployment Scenarios

  1. Ultra-High-Density Multi-Floor Building Distribution SAN Switch
    Compact 1RU rack form factor delivers maximum port density for departmental storage consolidation; 8 full-rate target ports connect primary disk storage arrays and tape libraries, 32 host ports attach thousands of application servers and blade workstations, eliminating need to deploy multiple smaller 20/24-port MDS edge switches.
  2. Large Enterprise Campus Core-Edge SAN Fabric
    Multiple DS-C9140-K9 edge switches deployed per building rack, interconnected via high-speed ISL trunk links to central MDS 9500 core director, forming unified enterprise-wide VSAN-separated production, test and backup storage fabrics for tens of thousands of end-users.
  3. Large Regional Mission-Critical Headquarters SAN
    Financial, healthcare and government headquarters require full dual power + fan redundancy to avoid site-wide catastrophic storage outages; integrates FICON mainframe DR replication workflows and centralized tape backup library consolidation in a single space-efficient 1RU chassis.
  4. Medium Service Provider Multi-Tenant PoP Edge Storage Switch
    VSAN isolation feature logically separates multiple customer storage environments on a single physical MDS 9140 switch, reducing hardware TCO for medium carrier PoP edge storage workloads with maximum host port density.
  5. Legacy MDS 9000 Series Hardware Upgrade
    Drop-in performance upgrade for aging MDS 9120 chassis, fully backward compatible with existing Fibre Channel SFP transceivers while delivering double the total port count and improved high-wattage power supply capacity for fully populated port deployments.

7. Standard Package Contents

1 × DS-C9140-K9 MDS 9140 1RU fixed Fibre Channel SAN switch chassis (front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety & compliance documentation

Items Sold Separately (Not Included)

  • Dual 300W AC hot-swappable redundant power supply units
  • Dual hot-swappable fan modules
  • DS-SFP-FC-2G-SW / DS-SFP-FC-2G-LW Fibre Channel SFP optical transceivers for all FC ports
  • RS232 serial console rollover cable
  • Fibre channel patch cords, cable management accessories, rack cable guides

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco DS-C9140-K9 is an End-of-Sale obsolete flagship 1RU horizontal 40-port fixed Fibre Channel SAN fabric switch from the MDS 9100 non-E Series, supplied bare without power supplies, fan modules and FC SFP transceivers (all FRUs sold separately). Built on an 80 Gbps shared bus backplane architecture with 40 autosensing 1/2G FC SFP ports split into 8 full-rate target ports and 32 oversubscribed host ports, front-to-back cold-aisle airflow, dual hot-swappable 300W AC redundant power supply bays and dual independent hot-swappable fan modules with full OIR live FRU replacement support. Running Cisco SAN-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, FICON mainframe support, port zoning, NPV edge switch mode, RBAC security and DCNM centralized SAN monitoring. Optimized for ultra-high-density enterprise building distribution, large campus core-edge and medium carrier multi-tenant PoP edge storage deployments with complete dual power + cooling redundancy; holds the maximum native port count of classic non-T MDS 9100 fixed chassis line, limited by oversubscribed host port architecture and lack of 4G/16G/32G high-speed Fibre Channel generation support compared to modern MDS 9132T series switches. Compliant with global safety, EMI, NEBS and RoHS industrial standards, fully out of Cisco official hardware support since October 10, 2013.
Click:14 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联