Cisco MDS 9134 (DS-C9134-K9) Full Product Description
1. Short Sales Title
Cisco DS-C9134-K9 1RU Fixed 34-Port Multilayer Fibre Channel SAN Fabric Switch, 32×Auto-Sensing 1/2/4G FC SFP Ports + 2×Dedicated 10G X2 Uplink Ports, On-Demand Port Licensing (24/32 FC Ports), Dual Hot-Swap 300W AC Redundant Power Supplies, Dual Hot-Swap Fan Modules, Full Non-Blocking 416 Gbps Fabric, SAN-OS/NX-OS Dual Software Support, NPV/NPIV Edge Mode, VSAN Isolation, FICON Mainframe Compatibility, OIR Hot-Swap FRU Design, End-of-Sale Mid-to-Large Enterprise Top-of-Rack Edge SAN Switch for High-Density Server, Disk Array, Tape Library and Multi-Site Consolidated Storage Workloads
2. Official Product Overview
The Cisco DS-C9134-K9 is the standard AC-powered base SKU of the MDS 9134 fixed 1RU multilayer Fibre Channel fabric switch within the Cisco MDS 9100 storage switch family, released early 2000s, End-of-Sale Jan 7, 2014, End-of-Support Jan 7, 2019, fully obsolete with no active Cisco TAC engineering supportCisco. It runs unified Cisco SAN-OS (legacy) / NX-OS modern software shared with MDS 9200/9500 modular directors, delivering consistent end-to-end enterprise SAN fabric management for mid-to-large data center storage area networks.
Core Hardware Differentiators vs DS-C9124-K9
-
Higher total port count: 32×4G FC SFP ports plus two exclusive 10G X2 uplink ports (total 34 ports), dedicated high-speed ISL backbone links for core-edge SAN architecture, absent on MDS 9124.
-
Larger non-blocking fabric capacity: 416 Gbps full-duplex aggregate bandwidth vs 192 Gbps on MDS 9124, optimized for high-density multi-10G inter-switch trunk workloads.
-
Scalable port licensing baseline: Ships with 24 active FC ports factory-default, expandable to full 32 FC ports via single 8-port software license upgrade (MDS 9124 starts with only 8 base ports).
-
Dual independent hot-swappable fan modules with full front-to-back fixed airflow, designed for standard cold aisle rack containment (no reversed hot-aisle airflow variant).
-
Native 10G X2 uplink hardware built-in for high-speed fabric interconnection to MDS 9500 core directors, eliminating need for extra expansion modules for backbone ISLs.
Core High-Availability Design
All FRUs support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric outage. Dual identical 300W AC power supplies provide 1+1 power redundancy; dual separate fan modules eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to avoid fabric-wide broadcast storms. NPV edge mode offloads host N_Port registration to upstream MDS 9500 directors for simplified large rack-scale edge SAN scaling.
Target deployment scenarios: Mid-to-large enterprise ultra-high-density multi-floor building distribution SAN, large regional headquarters high-availability disaster recovery SAN, medium service provider multi-tenant PoP edge, centralized tape library backup fabric aggregation, and unified campus core-edge SAN deployments interoperable with MDS 9200/9500 core directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage switch part number prefix
-
9134: MDS 9100 fixed fabric series, total 34 ports (32 FC host/storage + 2×10G uplink) classic non-T generation
-
K9: Standard AC power SKU with full multilayer SAN feature license (DS-C9134-HV-K9 is separate high-voltage DC telecom variant; PSUs/fans non-interchangeable between AC/HV SKUs)
Chassis Port & Hardware Layout Definition
-
Front Fibre Channel Ports
-
Ports 1–32: Hot-swappable SFP slots, autosensing 1/2/4 Gbps Fibre Channel, all full non-blocking line-rate bandwidth; factory activates 24 ports by default, upgrade license unlocks all 32 FC ports
-
Ports 33–34: Dedicated fixed X2 10Gbps Fibre Channel uplink ports for high-speed ISL core backbone inter-switch links
-
Out-of-Band Management Interfaces
-
RJ45 RS232 serial console port for local CLI access
-
Isolated 10/100BASE-T Ethernet out-of-band management port for remote SSH/Telnet/SNMP
-
Physical reset button for factory default recovery
-
Front Diagnostic LED Bank: Global system status, power supply A/B, fan module, FC port, 10G uplink port, link/activity, fault alarm, UID blue beacon indicator
-
Rear Compartment Layout: Dual independent hot-swappable 300W AC power supply bays + dual separate hot-swappable fan modules
-
Airflow Specification: Fixed front-to-back cold air intake at port panel, hot exhaust from rear power supply compartment (cold aisle standard only, no reversed airflow option)
Supported Transceivers & Power Options
-
Fibre Channel SFP transceivers (sold separately):
-
DS-SFP-FC4G-SW: 4Gbps short-wave multimode (500m)
-
DS-SFP-FC4G-LW: 4Gbps long-wave single-mode (10km)
-
Backward compatible with 2G / 1G FC SFPs
-
10G uplink transceivers: DS-X2-FC10G-SR / DS-X2-FC10G-LW X2 modules for dedicated 10G ports
-
Power supply compatibility: Only 300W AC PSUs for DS-C9134-K9; HV DC 3000W PSUs exclusive to DS-C9134-HV-K9 variant, non-interchangeable
-
No Ethernet downlink ports; purpose-built exclusively for Fibre Channel block storage SAN workloads
3. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Total non-blocking fabric aggregate capacity: 416 Gbps full-duplex system-wide bandwidth
-
Wire-speed forwarding rate: Up to 416 Mpps Fibre Channel frame switching at full line rate
-
Low-latency dynamic shared packet buffer pool optimized for OLTP database, virtualization and backup tape burst I/O
-
FC address table capacity: 1,048,576 N_Port identifiers
-
Maximum VSANs: 4094 isolated virtual storage fabrics
-
Maximum active zone sets: 256 zone sets, up to 2000 zones per fabric
-
Jumbo FC frame MTU support: Up to 9000 bytes
-
Port modes supported: F (Fabric host), FL (Loop), TL (Extended Loop), E (ISL), TE (Extended ISL), NP (NPV edge host)
-
Link aggregation: PortChannel for multi-port FC ISL trunking, max 8 ports per logical bundle
-
NPV/NPIV native feature: Consolidate hundreds of blade server host ports upstream to MDS core directors without core fabric overhead
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 300W AC PSU fully powers full chassis independently (1+1 N+1 failover)
-
AC input voltage range: 100–240V 50/60Hz universal auto-ranging AC
-
Fan modules: Two separate hot-swappable multi-fan assemblies; single fan module failure triggers SNMP alert without SAN traffic outage, minimum two functional fans required for stable operation
-
Airflow: Fixed front-to-back cold aisle intake, rear hot exhaust
-
Real-time monitoring: Fan RPM, internal chassis temperature, PSU voltage, SFP/X2 optical power, port and module fault logging via console syslog and SNMP v1/v2c/v3 traps
Physical & Environmental Parameters
-
Rack form factor: 1 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 4.45 cm × 44.45 cm × 40.64 cm (1.75 × 17.5 × 16 inches; extended depth 71.37cm with cable management guide)
-
Bare chassis weight: 9.98 kg (22 lbs) without power supplies/fan modules; fully loaded max weight 12.7 kg (28 lbs) with dual PSUs and dual fan trays installed
-
Operating temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 3000 meters
-
Storage temperature range: -40°C to 75°C (-40°F–167°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant
Out-of-Band Management Interfaces
-
RJ45 RS232 serial console port for local CLI access
-
Dedicated isolated 10/100BASE-T out-of-band Ethernet management port
-
Front panel multi-status LED bank for real-time hardware health visibility
4. Full SAN-OS / NX-OS Multilayer Feature Set
Layer 2 Fibre Channel Switching & Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric isolation for multi-application/multi-tenant storage segmentation
-
Hard port zoning + soft WWN zoning for granular host-storage access control
-
Full FICON protocol support for IBM mainframe disk/tape storage connectivity
-
Inter-Switch Link (ISL) trunking, PortChannel load balancing across mixed 4G FC and 10G X2 uplink ports
-
DTP Fibre Channel trunk negotiation, FSPF fabric dynamic domain ID routing
-
Local SPAN, RSPAN remote SAN traffic mirroring for storage performance troubleshooting
-
Broadcast/multicast storm suppression per FC port to eliminate fabric flooding outages
-
NPV N_Port Virtualizer edge switch mode for large core-edge SAN scaling
Multilayer Storage Routing & Multicast Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch SAN topologies
-
PIM-SM IP multicast for cross-fabric backup replication traffic
-
Static FC route configuration for cross-VSAN inter-fabric connectivity
-
Licensed IVR Inter-VSAN Routing feature for controlled data movement between isolated VSANs
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered storage traffic classification
-
Ingress frame policing, egress bandwidth shaping to throttle low-priority backup/replication streams
-
Pre-built QoS templates for production OLTP, tape backup, and disaster recovery replication streams
-
Dedicated high-priority queue for low-latency database and virtualization I/O workloads
Enterprise SAN Security Suite
-
Port security: Static WWN locking to block unauthorized server/storage device attach
-
RBAC Role-Based Access Control granular CLI user privilege partitioning
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, encrypted startup configuration files
-
DH-CHAP mutual authentication for ISL inter-switch link fabric authentication
-
Port lockdown, VSAN read-only access permissions, full audit logging for all fabric configuration changes
-
Compatible with external MDS SSM encryption and replication service modules
Monitoring & SAN Management Tools
-
Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring and provisioning
-
Isolated out-of-band Ethernet management port for offline device access during fabric outages
-
Onboard flash storage for SAN-OS/NX-OS image upgrades and configuration backup archives
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, latency, frame error counters, SFP/X2 optical power diagnostics
-
Event notification via email, syslog and SNMP traps for fabric fault alerting
5. High Availability Capabilities (Core Differentiators vs DS-C9124-K9)
-
Dual hot-swappable redundant 300W AC power supplies (1+1 power failover, single PSU fully operational under full 34-port load)
-
Dual independent hot-swappable fan modules with individual fault detection and real-time SNMP fault alerting
-
Full OIR Online Insertion and Removal support for fan modules, power supplies and SFP/X2 transceivers; live FRU replacement without chassis power shutdown or SAN traffic drop
-
All 32 FC ports full non-blocking 4Gbps bandwidth plus two dedicated 10G X2 uplink ports for high-speed core ISL trunks (absent on MDS 9124)
-
Default 24 active FC ports out of factory, only single 8-port license needed to unlock full 32 FC capacity (lower initial licensing cost vs MDS 9124 starting at 8 ports)
-
NPV edge switch mode simplifies large core-edge enterprise SAN architecture deployments
-
VSAN fabric isolation limits fault domains to single virtual storage segment, preventing fabric-wide broadcast storms
-
FSPF dynamic routing automatic failover to alternate ISL paths with sub-second convergence
-
Limitation: Fixed front-to-back airflow only, no modular port card expandability like MDS 9200/9509 directors, no native 16G/32G FC generation support
6. Typical Deployment Scenarios
-
Mid-to-Large Enterprise Multi-Floor Building Distribution SAN Switch
Compact 1RU rack form factor delivers high-density 32×4G FC host ports plus two built-in 10G uplinks for inter-building core trunking; scalable port licensing allows customers to start with 24 ports and expand to full 32 as storage capacity grows, consolidating thousands of application servers and disk arrays for multi-story office facilities.
-
Large Enterprise Campus Core-Edge SAN Fabric
Multiple DS-C9134-K9 edge switches deployed per building rack, utilizing dedicated 10G X2 uplinks to form high-speed ISL trunks connecting to central MDS 9500 core director, forming unified enterprise-wide VSAN-separated production, test and backup storage fabrics.
-
Large Regional Mission-Critical Headquarters SAN
Financial, healthcare and government headquarters storage deployments require full dual power + fan redundancy to avoid backup tape library and database storage outages; integrated FICON support enables mainframe DR replication workflows with native high-speed 10G backbone uplinks.
-
Medium Service Provider Multi-Tenant PoP Storage Edge
VSAN isolation feature logically separates multiple customer storage environments on a single physical MDS 9134 switch, reducing hardware TCO for medium carrier PoP edge storage workloads with built-in 10G uplinks for core backbone connectivity.
-
Legacy MDS 9000 Series Hardware Upgrade
Drop-in performance upgrade for aging MDS 9124 fixed fabric switches, fully backward compatible with existing 4G Fibre Channel SFP transceivers while delivering extra 8 FC ports plus dedicated 10G ISL uplink ports and higher default licensed port count.
7. Standard Package Contents
1 × DS-C9134-K9 MDS 9134 1RU fixed Fibre Channel SAN switch chassis (front-to-back cold aisle airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety & compliance documentation
Items Sold Separately (Not Included)
-
Dual 300W AC hot-swappable redundant power supply units
-
Dual hot-swappable fan modules
-
DS-SFP-FC4G-SW / DS-SFP-FC4G-LW Fibre Channel SFP optical transceivers for FC host ports
-
DS-X2-FC10G-SR / DS-X2-FC10G-LW X2 10G uplink transceivers for dedicated 10G ports
-
Optional single 8-port FC expansion software license to unlock full 32 FC ports
-
RS232 serial console rollover cable
-
Fibre channel patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9134-K9 is an End-of-Sale obsolete 1RU horizontal fixed Fibre Channel SAN fabric switch from the MDS 9100 non-E Series, supplied bare without power supplies, fan modules and FC SFP/X2 transceivers (all FRUs sold separately). Built on a 416 Gbps non-blocking fabric architecture with 32 autosensing 1/2/4G FC SFP ports (24 active default, expandable to 32 via single software license) plus two dedicated 10G X2 uplink ports for high-speed ISL core trunks, front-to-back cold-aisle airflow, dual hot-swappable 300W AC redundant power supply bays and dual independent hot-swappable fan modules with full OIR live replacement support. Running Cisco SAN-OS / NX-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, FICON mainframe support, port zoning, NPV edge switch mode, RBAC security and DCNM centralized monitoring. Optimized for mid-to-large enterprise multi-floor building distribution SAN, large campus core-edge and medium carrier multi-tenant PoP edge deployments with complete dual power + cooling redundancy; superior to DS-C9124-K9 via built-in 10G uplink ports, higher default licensed port count and larger fabric bandwidth, limited by fixed front-to-back airflow and lack of modular port card expandability compared to MDS 9200/9500 director series. Compliant with global safety, EMI, NEBS and RoHS industrial standards, fully out of Cisco official hardware support since January 7, 2019.
|