Cisco DS-C9124-K9 (MDS 9124) Full Product Description
1. Short Sales Title
Cisco DS-C9124-K9 1RU Fixed 24-Port 4Gbps Multilayer Fibre Channel SAN Fabric Switch, On-Demand Port Licensing (8/16/24 active ports), Dual Hot-Swap 300W AC Redundant Power Supplies, Dual Hot-Swap Variable-Speed Fan Modules, Full Non-Blocking Per-Port 4Gbps Bandwidth, SAN-OS/NX-OS Multilayer Storage Switching, VSAN Isolation, FICON Mainframe, NPV Edge Mode, OIR Hot-Swap FRU Design, End-of-Sale Mid-Size Enterprise Edge SAN Switch for Scalable Server, Disk Array, Tape Library and Multi-Site Storage Consolidation Workloads
2. Official Product Overview
The Cisco DS-C9124-K9 is the standard AC-powered base SKU of the MDS 9124 fixed 1RU multilayer Fibre Channel fabric switch in the Cisco MDS 9100 series, released mid-2000s, End-of-Sale Oct 30, 2013, End-of-Support Oct 31, 2018, fully obsolete with no active Cisco TAC engineering support. It runs unified Cisco SAN-OS / NX-OS software shared with MDS 9200 / 9500 modular directors, delivering consistent end-to-end enterprise SAN fabric management.
Core Hardware Differentiators vs DS-C9120-K9
-
24 total autosensing FC ports (vs 20 ports on MDS 9120),every port dedicated full 4Gbps non-blocking bandwidth(no host-side oversubscription on MDS 9120)Cisco.
-
Flexible on-demand port licensing: Ships with 8 active ports by default, expandable in 8-port increments to 16 or full 24 ports via software license without hardware replacement.
-
Higher total system fabric capacity: 192 Gbps aggregate full-duplex bandwidth vs 20 Gbps shared bus on MDS 9120.
-
Native NPV (N_Port Virtualizer) edge switch mode optimized for large core-edge SAN architectures, a limited feature on MDS 9120.
-
Dual shared hot-swappable fan trays supporting reversible airflow options (red front-intake / blue rear-intake fans for cold/hot aisle rack layouts).
Core High-Availability Design
All FRUs support OIR Online Insertion and Removal for live hot-swap maintenance without SAN fabric outage. Dual identical AC power supplies provide 1+1 power redundancy; dual independent fan modules eliminate single cooling failure risk. VSAN virtual fabric segmentation isolates fault domains to avoid fabric-wide broadcast storms. NPV mode offloads host registration to upstream MDS 9500 directors for simplified edge SAN scaling.
Target deployment scenarios: Mid-size enterprise multi-floor building distribution SAN, medium regional branch high-availability disaster recovery SAN, small-to-medium service provider multi-tenant PoP edge, tape library backup fabric aggregation, and mid-scale unified campus SAN core-edge deployments interoperable with MDS 9200/9500 core directors.
Model Suffix Breakdown
-
DS-C: Cisco MDS storage switch part number prefix
-
9124: MDS 9100 fixed fabric series, total 24 autosensing Fibre Channel SFP ports
-
K9: Standard AC power SKU with base multilayer SAN feature license (DS-C9124-HV-K9 is separate high-voltage DC telecom variant, PSUs/fans non-interchangeable between airflow variants)
Chassis Port & Hardware Layout Definition
-
Front Panel Fibre Channel Ports: 24×hot-swappable SFP slots, autosensing 1/2/4 Gbps Fibre Channel, all ports full non-blocking 4Gbps bandwidth (no oversubscription)
-
Ports 1–8: Default licensed active ports out of factory
-
Ports 9–24: On-demand licensed expansion ports (activate via 8-port license upgrades)
-
Out-of-Band Management Interfaces:
-
RJ45 RS232 serial console port for local CLI access
-
Isolated 10/100BASE-T Ethernet out-of-band management port for remote SSH/Telnet/SNMP
-
Physical reset button for factory default recovery
-
Front Diagnostic LED Bank: Global system status, power supply A/B, fan module, port link/activity, fault alarm, UID blue beacon indicator
-
Rear Compartment Layout: Dual independent hot-swappable 300W AC power supply bays + dual separate hot-swappable fan modules
-
Airflow Specification Two options:
-
Red fan/PSU: Front-to-back cold intake at port panel, rear hot exhaust (cold aisle standard)
-
Blue fan/PSU: Back-to-front rear cold intake, front hot exhaust (hot aisle containment racks)
Supported Transceivers & Power Options
-
Fibre Channel SFP transceivers (sold separately):
-
DS-SFP-FC4G-SW: 4Gbps short-wave multimode (500m)
-
DS-SFP-FC4G-LW: 4Gbps long-wave single-mode (10km)
-
Backward compatible with 2G / 1G FC SFPs
-
Power supply compatibility: Only 300W AC PSUs for DS-C9124-K9; HV DC PSUs exclusive to DS-C9124-HV-K9, non-interchangeable
-
No Ethernet downlink ports; purpose-built exclusively for Fibre Channel block storage SAN workloads
3. Hardware & Physical Specifications
Core SAN Switching & Routing Performance
-
Total non-blocking fabric capacity: 192 Gbps full-duplex aggregate bandwidthCisco
-
Wire-speed forwarding rate: Up to 192 Mpps Fibre Channel frame switching
-
Dynamic shared low-latency packet buffer pool optimized for OLTP database and backup tape burst I/O
-
FC address table capacity: 1,048,576 N_Port identifiers
-
Maximum VSANs: 4094 isolated virtual storage fabrics
-
Maximum active zone sets: 256 zone sets, up to 2000 zones per fabric
-
Jumbo frame FC MTU support: Up to 9000 bytes
-
Port modes supported: F (Fabric host), FL (Loop), TL (Extended Loop), E (ISL), TE (Extended ISL), NP (NPV edge host)
-
Link aggregation: PortChannel for multi-port ISL trunking, max 8 FC ports per logical bundle
-
NPV feature: N_Port Virtualizer edge mode to consolidate hundreds of host ports upstream to core MDS directors
Power & Cooling System
-
Power supply bays: 2 hot-swappable redundant slots, each 300W PSU fully powers full chassis independently (1+1 N+1 failover)
-
AC input voltage range: 100–240V 50/60Hz universal auto-ranging AC
-
Fan modules: Two separate hot-swappable multi-fan assemblies, minimum two functional fans required to avoid thermal shutdown; single fan failure triggers SNMP alert without SAN traffic outage
-
Dual airflow hardware options (red / blue color coded PSUs/fans, non-interchangeable)
-
Real-time monitoring: Fan RPM, internal chassis temperature, PSU voltage, SFP optical power, port fault logging via console syslog and SNMP v1/v2c/v3 traps
Physical & Environmental Parameters
-
Rack form factor: 1 RU standard 19-inch horizontal rack mount
-
Dimensions (H × W × D): 4.45 cm × 44.45 cm × 40.64 cm (1.75 × 17.5 × 16 inches; extended depth 71.37cm with cable guide)
-
Bare chassis weight: 8.4 kg (18.5 lbs) without power supplies/fan modules; fully loaded max weight 10.9 kg (24 lbs) with dual PSUs and dual fan trays installed
-
Operating temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 3000 meters
-
Storage temperature range: -40°C to 75°C (-40°F–167°F)
-
Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
-
Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant
Supervisor/Control Plane Out-of-Band Management Interfaces
-
RJ45 RS232 serial console port for local CLI access
-
Dedicated isolated 10/100BASE-T out-of-band Ethernet management port
-
Front panel multi-status LED bank for real-time hardware health visibility
4. Full SAN-OS / NX-OS Multilayer Feature Set
Layer 2 Fibre Channel Switching & Fabric Services
-
VSAN Virtual Storage Area Network: Logical fabric isolation for multi-application/multi-tenant storage segmentation
-
Hard port zoning + soft WWN zoning for granular host-storage access control
-
Full FICON protocol support for IBM mainframe disk/tape storage connectivity
-
Inter-Switch Link (ISL) trunking, PortChannel load balancing across multiple FC ports
-
DTP Fibre Channel trunk negotiation, FSPF fabric dynamic domain ID routing
-
Local SPAN, RSPAN remote SAN traffic mirroring for storage performance troubleshooting
-
Broadcast/multicast storm suppression per FC port to eliminate fabric flooding outages
-
NPV N_Port Virtualizer edge switch mode for large core-edge SAN scaling
Multilayer Storage Routing & Multicast Features
-
FSPF Fibre Channel Shortest Path First dynamic fabric routing for multi-switch SAN topologies
-
PIM-SM IP multicast for cross-fabric backup replication traffic
-
Static FC route configuration for cross-VSAN inter-fabric connectivity
-
Licensed IVR Inter-VSAN Routing feature for controlled data movement between isolated VSANs
Advanced SAN QoS & Traffic Prioritization
-
Four hardware priority queues per Fibre Channel port for tiered storage traffic classification
-
Ingress frame policing, egress bandwidth shaping to throttle low-priority backup/replication streams
-
Pre-built QoS templates for production OLTP, tape backup, and disaster recovery replication
-
Dedicated high-priority queue for low-latency database and virtualization I/O workloads
Enterprise SAN Security Suite
-
Port security: Static WWN locking to block unauthorized server/storage device attach
-
RBAC Role-Based Access Control granular CLI user privilege partitioning
-
SSHv2 encrypted remote CLI management, SNMPv3 secure monitoring, encrypted startup configuration files
-
DH-CHAP mutual authentication for ISL inter-switch link fabric authentication
-
Port lockdown, VSAN read-only access permissions, full audit logging for all fabric configuration changes
-
Compatible with external MDS SSM encryption and replication service modules
Monitoring & SAN Management Tools
-
Cisco Fabric Manager / DCNM-SAN centralized graphical SAN fabric monitoring and provisioning
-
Isolated out-of-band Ethernet management port for offline device access during fabric outages
-
Onboard flash storage for SAN-OS/NX-OS image upgrades and configuration backup archives
-
Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
-
Real-time storage telemetry: Port throughput, latency, frame error counters, SFP optical power diagnostics
-
Event notification via email, syslog and SNMP traps for fabric fault alerting
5. High Availability Capabilities (Core Differentiators vs DS-C9120-K9)
-
Dual hot-swappable redundant 300W AC power supplies (1+1 power failover, single PSU fully operational under full 24-port load)
-
Dual independent hot-swappable fan modules with individual fault detection and real-time SNMP fault alerting
-
Full OIR Online Insertion and Removal support for fan modules, power supplies and SFP transceivers; live FRU replacement without chassis power shutdown or SAN traffic drop
-
All 24 ports full non-blocking 4Gbps bandwidth (no oversubscription bottlenecks of MDS 9120)
-
On-demand port licensing enables pay-as-you-grow expansion without hardware replacement
-
NPV edge switch mode simplifies large core-edge enterprise SAN architecture deployments
-
VSAN fabric isolation limits fault domains to single virtual storage segment, preventing fabric-wide broadcast storms
-
FSPF dynamic routing automatic failover to alternate ISL paths with sub-second convergence
-
Limitation: Fixed 1RU compact chassis with no modular port card expandability like MDS 9200/9509 directors
6. Typical Deployment Scenarios
-
Mid-Size Enterprise Multi-Floor Building Distribution SAN Switch
Compact 1RU rack form factor fits standard server edge racks; scalable port licensing allows customers to start with 8 ports and expand to full 24 as storage capacity grows, consolidating thousands of IP servers and disk arrays for multi-story office facilities.
-
Medium Enterprise Campus Core-Edge SAN Fabric
Multiple DS-C9124-K9 edge switches deployed per building floor, interconnected via high-speed ISL trunk links to central MDS 9500 core director, forming unified enterprise-wide VSAN-separated production, test and backup storage fabrics.
-
Regional Mission-Critical Branch Office Disaster Recovery SAN
Financial, healthcare and government remote branch storage deployments require full dual power + fan redundancy to avoid backup tape library and database storage outages; integrated FICON support enables mainframe DR replication workflows.
-
Small Service Provider Multi-Tenant PoP Storage Edge
VSAN isolation feature logically separates multiple customer storage environments on a single physical MDS 9124 switch, reducing hardware TCO for small carrier PoP edge storage workloads.
-
Legacy MDS 9000 Series Hardware Upgrade
Drop-in performance upgrade for aging MDS 9120 first-generation fixed fabric switches, fully backward compatible with existing Fibre Channel SFP transceivers while delivering full non-blocking port bandwidth, NPV edge mode and scalable on-demand port licensing.
7. Standard Package Contents
1 × DS-C9124-K9 MDS 9124 1RU fixed Fibre Channel SAN switch chassis (airflow-neutral base chassis, fans/PSUs sold separately per airflow requirement)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety & compliance documentation
Items Sold Separately (Not Included)
-
Dual 300W AC hot-swappable redundant power supply units (red for front-to-back, blue for back-to-front airflow)
-
Dual hot-swappable fan modules (airflow color-matched to PSUs, non-interchangeable)
-
DS-SFP-FC4G-SW / DS-SFP-FC4G-LW Fibre Channel SFP optical transceivers
-
Optional 8-port / 16-port on-demand port activation software licenses
-
RS232 serial console rollover cable
-
Fibre channel patch cords, cable management accessories, rack cable guides
Short Commercial Catalog Version (For Quotation & Datasheet Use)
The Cisco DS-C9124-K9 is an End-of-Sale obsolete 1RU horizontal fixed Fibre Channel SAN fabric switch from the MDS 9100 non-E Series, supplied bare without power supplies, fan modules and FC SFP transceivers (all FRUs sold separately). Built on a 192 Gbps non-blocking fabric architecture with 24 autosensing 1/2/4G FC SFP ports (all full-rate no oversubscription), flexible on-demand 8-port incremental licensing expandable from 8 to full 24 active ports, dual hot-swappable 300W AC redundant power supply bays and dual interchangeable hot-swappable fan modules supporting front-to-back or back-to-front airflow for cold/hot aisle racks, with full OIR live FRU replacement support. Running Cisco SAN-OS / NX-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, FICON mainframe support, port zoning, NPV edge switch mode, RBAC security and DCNM centralized SAN monitoring. Optimized for mid-size enterprise edge SAN, scalable departmental storage distribution and medium branch disaster recovery SAN deployments with complete dual power + cooling redundancy; superior to DS-C9120-K9 via full non-blocking port bandwidth and pay-as-you-grow port licensing, limited by fixed chassis design without modular port card expandability of MDS 9200/9500 director series. Compliant with global safety, EMI, NEBS and RoHS industrial standards, fully out of Cisco official hardware support since October 31, 2018.
|