Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
71413565116
ProductName:
DS-C9120-K9
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco MDS 9120 (DS-C9120-K9) Full Product Description

1. Short Sales Title

Cisco DS-C9120-K9 1RU Fixed 20-Port Multilayer Fibre Channel SAN Fabric Switch, 4 Full-Rate Target Optimized FC SFP Ports + 16 Host-Optimized Oversubscribed FC SFP Ports, Dual Hot-Swap 300W AC Redundant Power Supplies, Dual Hot-Swap Variable-Speed Fan Modules, SAN-OS Multilayer Storage Switching, Full Fibre Channel/FICON Protocol Support, Integrated SAN Security, VSAN Isolation, OIR Hot-Swap FRU Design, End-of-Sale Small/Medium Enterprise Edge SAN Switch for Server, Disk Array, Tape Library and Multi-Site Storage Consolidation Workloads
image
Cisco MDS 9120 DS-C9120-K9 Front View

2. Official Product Overview

The Cisco DS-C9120-K9 is the base standard AC power variant of the MDS 9120 fixed 1RU multilayer Fibre Channel fabric switch from the Cisco MDS 9100 storage switch family, released early 2000s, End-of-Sale Oct 30, 2013, End-of-Support Oct 31, 2018, fully obsolete with no active Cisco TAC engineering supportCisco. It runs the unified Cisco SAN-OS software stack shared with MDS 9200/9500 modular directors, delivering consistent end-to-end SAN fabric management for small and medium data center storage area networks.
Distinct hardware architecture differentiates the MDS 9120 from larger MDS 9140 model:
  1. Total 20 SFP Fibre Channel ports split into two performance tiers: 4 dedicated full-rate target ports for high-speed disk/tape storage arrays, 16 oversubscribed host ports for server attach, optimized for mixed host/storage workload balanceCisco.
  2. Compact 1RU horizontal rack form factor with front-to-back airflow, designed for edge rack SAN deployments close to server and storage hardware.
  3. Fully redundant hot-swappable FRUs: dual 300W AC power supplies and dual independent fan modules, supporting OIR live replacement without SAN fabric outage.
  4. Autosensing 1Gbps / 2Gbps Fibre Channel SFP ports, supporting FL/F/TL/E/TE port types for host, fabric ISL and extended distance inter-switch linksCisco.
  5. Integrated multilayer storage services: VSAN segmentation, port security, fabric zoning, FICON mainframe connectivity, and SAN diagnostics, eliminating need for external service appliances for basic edge SAN policy enforcement.
Target deployment scenarios: Small enterprise edge rack SAN aggregation, medium business multi-floor storage consolidation, remote branch disaster recovery SAN, tape library backup fabric edge, and mid-size PoP storage edge for service provider multi-tenant VSAN isolation. It seamlessly inter-works with MDS 9200/9500 core directors to build unified enterprise-wide end-to-end SAN fabrics.

Model Suffix Breakdown

  • DS-C: Cisco MDS Storage Switch part number prefix
  • 9120: MDS 9100 fixed fabric series, total 20 Fibre Channel SFP ports
  • K9: Standard AC power SKU with base SAN-OS multilayer feature license (DS-C9120-HV-K9 is separate high-voltage DC power variant)

Chassis Port & Hardware Layout Definition

  1. Front Panel Fibre Channel Ports: 20×hot-swappable SFP slots, autosensing 1/2Gbps Fibre Channel
    • Ports 1–4: Full-rate target-optimized ports (no oversubscription, for high-performance storage arrays, tape libraries, ISL backbone links)
    • Ports 5–20: Host-optimized oversubscribed ports for server, virtualization host, blade server SAN attach
  2. Out-of-Band Management Interfaces:
    • RJ45 RS232 serial console port for local CLI access
    • Isolated 10/100BASE-T Ethernet out-of-band management port for remote Telnet/SSH/SNMP access
  3. Front Diagnostic LED Bank: Global system status, power supply A/B, fan module, port link/activity, fault alarm, UID beacon indicator
  4. Rear Compartment Layout: Dual independent hot-swappable 300W AC power supply bays + dual separate hot-swappable fan modules
  5. Airflow Specification: Front-to-back cold air intake at port panel, hot exhaust from rear power supply compartment

Supported Transceivers & Power Options

  1. Fibre Channel SFP transceivers (sold separately):
    • DS-SFP-FC-2G-SW: Short-wave 500m multimode 1/2G FC
    • DS-SFP-FC-2G-LW: Long-wave 10km single-mode 1/2G FC
  2. Power supply compatibility: Only 300W AC PSUs supported for DS-C9120-K9; HV DC power supplies exclusive to DS-C9120-HV-K9 variant, non-interchangeable
  3. No Ethernet downlink ports; purpose-built exclusively for Fibre Channel SAN storage workloads

3. Hardware & Physical Specifications

Core SAN Switching Performance

  • Total system shared fabric bandwidth: 20 Gbps aggregate capacity
  • Wire-speed forwarding rate: Up to 20 Mpps Fibre Channel frame switching
  • Dynamic shared packet buffer pool optimized for block storage read/write burst traffic
  • MAC/FC address table capacity: 64,000 FC N_Port identifiers
  • Maximum VSANs: 4094 isolated virtual storage fabrics
  • Maximum active zone sets: 256 zone sets, up to 2000 zones per fabric
  • Jumbo frame support: Up to 9000 byte Fibre Channel frame MTU
  • Port modes supported: F (Fabric host), FL (Loop), TL (Extended Loop), E (ISL), TE (Extended ISL)
  • Link aggregation: PortChannel for multi-port ISL trunking (max 8 FC ports per logical bundle)

Power & Cooling System

  • Power supply bays: 2 hot-swappable redundant slots delivering 1+1 N+1 power failover protection, each 300W PSU fully powers entire chassis independently
  • AC input voltage range: 100–240V 50/60Hz universal AC
  • Fan modules: Two separate hot-swappable multi-fan assemblies, single fan module failure triggers SNMP alert without SAN traffic outage
  • Airflow direction: Front-to-back cold aisle intake, rear hot exhaust
  • Real-time monitoring: Fan RPM, internal chassis temperature, PSU voltage, SFP transceiver and port fault logging via console syslog and SNMP v1/v2c/v3 traps

Physical & Environmental Parameters

  • Rack form factor: 1 RU standard 19-inch horizontal rack mount
  • Dimensions (H × W × D): 4.45 cm × 43.69 cm × 58.67 cm (1.75 × 17.2 × 23.1 inches; 71.37cm depth with cable management guide)Cisco
  • Bare chassis weight: 9.07 kg (20 lbs) without power supplies/fan modules; fully loaded max weight 11.34 kg (25 lbs) with dual PSUs and dual fan trays installedCisco
  • Operating temperature range: 0°C to 40°C (32°F–104°F); certified altitude up to 3000 meters
  • Storage temperature range: -40°C to 75°C (-40°F–167°F)
  • Relative humidity: 10%–90% non-condensing operating; 5%–95% non-condensing storage
  • Compliance Certifications: FCC Class A, UL 60950-1, CE, VCCI Class A, NEBS Level 3, RoHS compliant

4. Full SAN-OS Multilayer Feature Set (Cisco SAN-OS Release 1.x / 2.x)

Layer 2 Fibre Channel Switching & Fabric Services

  • VSAN Virtual Storage Area Network: Logical fabric isolation for multi-tenant, multi-application storage segmentation
  • Port zoning: Hard zoning (port-based) and soft zoning (WWN-based) for access control between servers and storage
  • IEEE FC-BB Fibre Channel bridging, FICON support for IBM mainframe storage connectivity
  • Inter-Switch Link (ISL) trunking, PortChannel load balancing across multiple FC ports
  • DTP Fibre Channel trunk negotiation, fabric domain ID management, fabric reconfiguration (FSPF) routing protocol
  • Local SPAN, RSPAN remote SAN traffic mirroring for storage performance troubleshooting
  • Broadcast/multicast storm suppression per FC port to eliminate storage fabric flooding

Multilayer Storage Routing & Multicast Features

  • FSPF Fibre Channel shortest path first dynamic fabric routing for multi-switch SAN topologies
  • PIM-SM IP multicast for SAN replication backup traffic
  • Static FC route configuration for cross-VSAN inter-fabric connectivity
  • IVR Inter-VSAN Routing licensed feature for controlled data movement between isolated VSANs

Advanced SAN QoS & Traffic Prioritization

  • Four hardware priority queues per Fibre Channel port for tiered storage traffic classification
  • Ingress frame policing, egress bandwidth shaping for backup/replication traffic throttling
  • Pre-built QoS templates for mission-critical production I/O, backup tape, and disaster recovery replication streams
  • Dedicated high-priority queue for low-latency database and OLTP storage workloads

Enterprise SAN Security Suite

  • Port security: Static WWN locking to restrict unauthorized server/storage device attach
  • Role-Based Access Control (RBAC) granular CLI user privilege partitioning
  • SSHv2 encrypted CLI remote management, SNMPv3 secure monitoring, encrypted startup configuration files
  • Fabric authentication: DH-CHAP mutual authentication for ISL inter-switch links
  • Port lockdown, VSAN read-only access permissions, audit logging for all fabric configuration changes
  • Integrated support for external MDS Storage Services Module (SSM) encryption and replication

Monitoring & SAN Management Tools

  • Cisco Fabric Manager centralized graphical SAN fabric monitoring and provisioning
  • Dedicated out-of-band Ethernet management port for offline device access during fabric outages
  • Onboard flash storage for SAN-OS image upgrades and configuration backup archives
  • Cisco Discovery Protocol (CDP) automatic MDS fabric neighbor device discovery
  • Real-time storage telemetry: Port throughput, latency, frame error counters, SFP optical power diagnostics
  • Event notification via email, syslog and SNMP traps for fabric fault alerting

5. High Availability Capabilities

  1. Dual hot-swappable redundant 300W AC power supplies (1+1 power failover, single PSU fully operational under full port load)
  2. Dual independent hot-swappable fan modules with individual fault detection and real-time SNMP alerting
  3. Full OIR Online Insertion and Removal support for fan modules, power supplies and SFP transceivers; live FRU replacement without chassis power shutdown or SAN traffic drop
  4. VSAN fabric isolation limits fault domains to single virtual storage segment, preventing fabric-wide broadcast storms
  5. FSPF dynamic routing automatic failover to alternate ISL paths with sub-second convergence
  6. Limitation: Fixed oversubscribed port architecture creates host-side bandwidth bottlenecks for ultra-high-density all-storage deployments; no modular port card expandability like MDS 9200/9500 series

6. Typical Deployment Scenarios

  1. Small Enterprise Edge Rack SAN Switch
    Compact 1RU form factor fits standard server rack edge positions; 4 full-rate target ports connect primary disk storage arrays, 16 host ports attach application servers and virtualization hosts, delivering isolated VSAN fabrics for production, test and backup storage environments.
  2. Medium Enterprise Multi-Floor Building Storage Distribution Aggregation
    Multiple DS-C9120-K9 switches deployed per floor rack, interconnected via high-speed ISL trunk links to central MDS 9500 core director, consolidating distributed server storage traffic into a unified enterprise-wide SAN fabric.
  3. Regional Mission-Critical Branch Office Disaster Recovery SAN
    Financial, healthcare and government remote branch storage deployments require full dual power + fan redundancy to avoid backup tape library and database storage outages; integrated FICON support enables mainframe DR replication workflows.
  4. Small Service Provider Multi-Tenant PoP Storage Edge
    VSAN isolation feature enables logical separation of multiple customer storage environments on a single physical MDS 9120 switch, reducing hardware TCO for small carrier PoP edge storage workloads.
  5. Legacy MDS 9000 Series Hardware Replacement
    Drop-in upgrade for aging MDS 9100 first-generation fixed fabric switches, fully backward compatible with existing Fibre Channel SFP transceivers and unified SAN-OS management workflows with MDS 9200/9500 core directors.

7. Standard Package Contents

1 × DS-C9120-K9 MDS 9120 1RU fixed Fibre Channel SAN switch chassis (front-to-back airflow)
19-inch standard horizontal rack mount rail kit; optional cable management guide extension
Hardware installation guide, global safety & compliance documentation

Items Sold Separately (Not Included)

  • Dual 300W AC hot-swappable redundant power supply units
  • Dual hot-swappable fan modules
  • DS-SFP-FC-2G-SW / DS-SFP-FC-2G-LW Fibre Channel SFP optical transceivers
  • RS232 serial console rollover cable
  • Fibre channel patch cords, cable management accessories, rack cable guides

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco DS-C9120-K9 is an End-of-Sale obsolete 1RU horizontal fixed Fibre Channel SAN fabric switch from the MDS 9100 non-E Series, supplied bare without power supplies, fan modules and FC SFP transceivers (all FRUs sold separately). Built on a 20 Gbps shared fabric architecture with 20 autosensing 1/2G FC SFP ports split into 4 full-rate target ports and 16 oversubscribed host ports, front-to-back cold-aisle airflow, dual hot-swappable 300W AC redundant power supply bays and dual independent hot-swap fan modules with full OIR live replacement support. Running Cisco SAN-OS multilayer storage software, it delivers VSAN virtual fabric isolation, FSPF dynamic SAN routing, FICON mainframe support, port zoning, RBAC security and Cisco Fabric Manager centralized monitoring. Optimized for small enterprise edge SAN, medium building storage distribution and high-availability branch disaster recovery storage deployments with complete dual power + cooling redundancy; limited by fixed oversubscribed port architecture and low total fabric bandwidth compared to larger MDS 9140/9200/9500 modular chassis. Compliant with global safety, EMI, NEBS and RoHS industrial standards, fully out of Cisco official hardware support since October 31, 2018.
Click:14 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联