Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
71410204916
ProductName:
WS-C4507R
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco Catalyst WS-C4507R Full English Product Description

1. Short Sales Title

Cisco WS-C4507R Classic Redundant 7-Slot Modular Campus Switch Chassis, 11RU Rack Height, Dual Hot-Swap Supervisor Slots (1+1 Redundant Supervisor Support), 5 Hot-Swappable Line Card Slots, Dual Redundant Power Supply Bays, Integrated Hot-Swap Fan Tray, Fixed 6 Gbps Per-Slot Backplane Bandwidth, Built-In Fabric Redundancy Modules, Supports Legacy Supervisor II/IV/V Series & Classic Catalyst 4500 Line Cards, Wire-Speed Layer 2–Layer 4 Switching, IEEE 802.3af/at PoE Compatible, End-of-Sale Enterprise Campus Core, Large Building Distribution & Medium Data Center Aggregation Chassis Demanding Full Supervisor + Power Redundancy

2. Official Product Overview

The Cisco Catalyst WS-C4507R is a legacy non-E redundant 7-slot modular chassis within the Catalyst 4500 mid-range campus switch platform, fully End-of-Sale and End-of-Support per Cisco lifecycle rules. It ships as a bare chassis with pre-installed fan tray and five factory-integrated fabric redundancy modules; supervisor engines, power supplies and line cards are sold separately as standalone FRUs (Field Replaceable Units)Cisco.
As the original redundant supervisor chassis in the classic Catalyst 4500 lineup, the WS-C4507R is distinct from non-R single-supervisor models (WS-C4503 / WS-C4506) and later enhanced WS-C4507R+E / WS-C4507R-E variants. It delivers native 1+1 redundant supervisor capability for SSO (Stateful Switchover), NSF (Nonstop Forwarding) and ISSU (In-Service Software Upgrade), eliminating single supervisor failure points for mission-critical campus core and building aggregation networksCisco.
Built on a passive shared-memory backplane with fixed 6 Gbps full-duplex bandwidth per line card slot, it cannot support E-series high-speed 24/48 Gbps line cards or modern 6-E/7-E/8-E supervisors, maintaining full backward compatibility only with legacy classic supervisors and standard 6Gbps PoE/PoE+ copper/fiber line cards. Target use cases include enterprise campus core switches, large multi-floor building distribution, regional branch core, and medium SMB data center aggregation requiring maximum hardware high availability.

Model Suffix Breakdown

  • WS-C: Cisco Catalyst LAN Switch Platform Identifier
  • 4507: Catalyst 4500 Series, total 7 modular slot chassis
  • R: Redundant chassis design with dual dedicated supervisor slots for 1+1 supervisor failover; unique fabric redundancy modules included

Chassis Slot Layout Definition (Top to Bottom Slots 1–7)

  1. Slot 1: Primary supervisor engine slot
  2. Slot 2: Secondary redundant supervisor engine slot (SSO/NSF failover supported)
  3. Slot 3, Slot 4, Slot 5, Slot 6, Slot 7: Five hot-swappable line card expansion slots for Gigabit copper, SFP fiber, PoE/PoE+ access modules
  4. Rear compartment: Dual independent hot-swappable power supply bays supporting 1+1 N+1 power redundancy
  5. Front lower bay: Single integrated hot-swappable cooling fan tray
  6. Built-in hardware: Five permanent fabric redundancy modules pre-installed for redundant supervisor traffic switching (unique to WS-C4507R classic chassis)Cisco

Supported Supervisor Engines

Only legacy classic supervisors compatible (E-series 6-E/7-E/8-E supervisors are not supported):
  • Supervisor Engine II, II-Plus, II-Plus-10GE
  • Supervisor Engine IV (WS-X4515)
  • Supervisor Engine V, V-10GE
    All classic supervisors run Cisco IOS 12.2EW train images, fully supporting SSO, NSF and ISSU when dual identical supervisors are deployed in slots 1 and 2.

Supported Line Card Modules

All standard classic Catalyst 4500 6 Gbps hot-swappable line cards are fully compatible:
  • 24/48-port 10/100/1000BASE-T copper non-PoE / IEEE 802.3af PoE / 802.3at PoE+ modules
  • SFP-based Gigabit fiber uplink line cards
  • 10GE uplink expansion line cards
    Total PoE power capacity depends on installed AC/DC PoE-capable power supply modules (1300W / 2800W ACV PSUs).

3. Hardware & Physical Specifications

Core Backplane & Switching Fabric

  • Total modular slots: 7 (2 dedicated supervisor slots, 5 line card expansion slots)
  • Per-line-card slot bandwidth: Fixed 6 Gbps full-duplex hard-limited backplane (no scalable 24/48 Gbps E-series fabric support)
  • Switching architecture: Centralized non-blocking shared-memory fabric with dedicated fabric redundancy modules for dual supervisor traffic isolation
  • Maximum port density: Up to 240×1G copper ports via five 48-port line cards; up to 60×1G SFP fiber ports
  • MAC address table capacity: Up to 16,384 MAC entries (varies by installed supervisor model)
  • TCAM size: Up to 64,000 ACL/QoS security flow entries
  • Jumbo frame support: Up to 9198 bytes across all copper and fiber interfaces

Power System

  • Power supply bays: 2 hot-swappable redundant slots (1+1 power failover supported)
  • Supported PSU models: AC 1000W data-only, AC 1300W/2800W PoE-capable ACV, DC 1400W telecom PSU
  • Input voltage range: AC 100–240V 50/60Hz; DC –48V standard telecom negative power
  • Maximum total PoE budget: Up to 1440W with dual 2800WACV PoE power supplies
  • Hot-swap capability: Power supplies can be live replaced without chassis full shutdown

Cooling System

  • Fan tray: Single integrated hot-swappable fan assembly factory pre-installed with chassis
  • Airflow direction: Right-to-left internal module airflow; front-to-back power supply airflow
  • Status monitoring: Real-time fan speed, internal temperature, and hardware fault alarms via front-panel LEDs, console logs and SNMP traps

Physical & Environmental Parameters

  • Rack form factor: 11 RU standard 19-inch rack mount; optional 23-inch rack mounting brackets included
  • Dimensions (H × W × D): 48.74 cm × 43.97 cm × 31.70 cm (19.19 × 17.31 × 12.50 inches)
  • Weight: 20.1 kg (44.25 lbs) bare chassis with fan tray; maximum fully loaded weight 45.4 kg (100 lbs) with dual PSUs, dual supervisors and full line card slots populated
  • Operating temperature: 0°C to 40°C (32°F–104°F); operating altitude -60m up to 3000m
  • Storage temperature: -40°C to 75°C (-40°F–167°F)
  • Relative humidity: 10%–90% non-condensing
  • Compliance Certifications: FCC Class A, UL 60950, CE, VCCI Class A, NEBS Level 3, RoHS compliant

Supervisor Out-of-Band Management Interfaces (Dual Supervisor Identical Ports)

  • RJ45 RS232 serial console port
  • Optional mini USB console port on late-model Supervisor V-10GE
  • Dedicated out-of-band 10/100BASE-T Ethernet management port
  • Dual uplink slots (GBIC / SFP / XFP for 1G / 10GE based on supervisor variant)
  • Front LED bank: System, fan, power, module, uplink, fault, UID beacon status indicators

4. Full Layer 2 & Layer 3 IOS Feature Set

Layer 2 Switching Features

  • IEEE 802.1D STP, 802.1w Rapid STP, 802.1s MSTP
  • Maximum 4096 VLANs, 802.1Q trunking + ISL proprietary trunk encapsulation
  • Private VLAN, Q-in-Q VLAN stacking for multi-tenant segmentation
  • Port security, static/dynamic MAC address learning, MAC filtering
  • 802.3ad LACP static EtherChannel link aggregation (max 8 ports per bundle)
  • Broadcast/multicast/unicast storm suppression
  • IGMPv1/v2/v3 snooping, CGMP for VoIP and IPTV multicast optimization
  • Voice VLAN auto-detection for Cisco IP phones
  • 802.3x full-duplex flow control
  • SPAN local port mirroring, RSPAN remote traffic analysis

Layer 3 Routing & Multicast Features (IP Base / IP Services IOS Images)

  • Static IP routing, RIP v1/v2, EIGRP, OSPF v2; limited IPv6 support on Supervisor V
  • Wire-speed SVI inter-VLAN routing
  • PIM-SM / PIM-DM multicast routing, MSDP
  • ECMP equal-cost multi-path load balancing
  • Policy-Based Routing (PBR) available with IP Services license
  • Basic VRF-Lite multi-tenancy only supported on Supervisor V engines

QoS & Traffic Prioritization

  • Hierarchical MQC modular QoS policy framework
  • 8 hardware priority queues per physical port, 802.1p CoS / DSCP bidirectional mapping
  • Ingress policing, egress shaping, traffic marking and remarking
  • Auto-QoS pre-built templates optimized for VoIP, video conferencing, IP surveillance
  • Dedicated expedite voice queue for PoE IP phone traffic

Enterprise Security Suite

  • IEEE 802.1X port-based NAC authentication with RADIUS/TACACS+ AAA integration
  • DHCP Snooping, Dynamic ARP Inspection (DAI), IP Source Guard
  • Port ACL, VLAN ACL (VACL), route ACL hardware traffic filtering
  • SSHv2 encrypted CLI management, SNMPv3 secure monitoring
  • Control Plane Policing (CoPP) to protect supervisor CPU from DDoS attacks
  • Rogue AP detection, private VLAN host isolation

PoE Power Management

  • IEEE 802.3af PoE (15.4W per port) / 802.3at PoE+ (30W per port) line card compatibility
  • Per-port power priority scheduling for critical voice, wireless, and surveillance endpoints
  • Real-time power budget monitoring, automatic power throttling for over-subscription protection
  • Cisco EnergyWise power-saving management for idle PoE devices

5. High Availability Capabilities (Core Differentiator vs Non-R Chassis)

  1. Dual Redundant Supervisor Engines (1+1)
    Deploy matching classic supervisors in slots 1 & 2 to enable SSO stateful switchover, NSF nonstop forwarding and ISSU in-service software upgrades; sub-minute failover with preserved Layer 2/Layer 3 forwarding tables.
  2. Dedicated fabric redundancy modules for isolated redundant supervisor traffic paths (unique WS-C4507R hardware feature).
  3. Dual hot-swappable redundant AC/DC power supplies (1+1 power failover protection).
  4. Full OIR Online Insertion and Removal support: hot-swap fan tray, line cards and power supplies live without chassis shutdown.
  5. Variable fan fault detection with SNMP/console alerting for proactive maintenance.

6. Typical Deployment Scenarios

  1. Enterprise Campus Core Switch
    Dual redundant supervisors eliminate single point of failure for multi-building campus backbone; five line card slots aggregate multiple building distribution switches via 1G/10G fiber trunks, supporting unified voice, video and data core routing.
  2. Large Multi-Floor Building Distribution Aggregation
    High port density accommodates full PoE access lines for entire office towers; dual supervisor redundancy ensures zero downtime for critical business communications like IP telephony and video surveillance.
  3. Regional Large Branch Office Core Switch
    Mission-critical branch networks require full supervisor + power redundancy to avoid remote site outages, integrating inter-VLAN Layer 3 routing and high-density PoE Wi-Fi AP power delivery.
  4. Medium SMB Data Center Aggregation Switch
    Fiber line cards connect server racks and storage arrays; redundant supervisors protect leaf-spine architecture forwarding, supporting wire-speed Layer 3 inter-server traffic and backup WAN uplinks.
  5. Legacy Catalyst 4500 Redundant Infrastructure Refresh
    Drop-in replacement for aging WS-C4007 redundant chassis, fully compatible with existing classic PoE line cards and legacy supervisors to extend high-availability network hardware lifecycle.

7. Standard Package Contents

1 × WS-C4507R Classic redundant 7-slot empty chassis
1 × Pre-installed integrated hot-swappable fan tray
5 factory pre-mounted fabric redundancy modules (unique to WS-C4507R)
19-inch standard rack mount rail kit; optional 23-inch rack mounting hardware
Hardware installation guide, global safety & compliance documentation

Items Sold Separately (Not Included)

  • Classic Supervisor Engine (II / IV / V series variants, minimum two identical units for redundancy)
  • AC / DC redundant power supply units (PoE or data-only models)
  • Classic 6 Gbps Gigabit copper/fiber PoE/PoE+ line cards
  • GBIC / SFP / XFP optical transceivers for supervisor uplink ports
  • Console cable, cable management accessories

Short Commercial Catalog Version (For Quotation & Datasheet Use)

The Cisco Catalyst WS-C4507R is an End-of-Sale classic redundant 11RU 7-slot modular campus switch chassis from the Catalyst 4500 non-E Series, supplied bare with factory pre-installed fan tray and five fabric redundancy modules (power supplies, classic dual supervisors and line cards sold separately). Featuring dual dedicated supervisor slots for 1+1 SSO/NSF/ISSU redundant failover, 5 hot-swappable fixed 6 Gbps backplane line card slots, dual hot-swappable redundant power supply bays and full OIR hot-swap FRU support. Compatible with legacy Catalyst 4500 classic supervisor engines and standard PoE/PoE+ Gigabit copper/fiber line cards, delivering wire-speed Layer 2–Layer 4 switching, full Cisco IOS Layer 3 routing, advanced MQC QoS, enterprise security suite, IGMP multicast snooping and 802.1X NAC. Optimized for mission-critical enterprise campus core, large building distribution and high-availability branch/data center deployments with complete supervisor + power redundancy. Compliant with global industrial safety, EMI and RoHS standards, covered by Cisco limited hardware warranty during active support lifecycle.
Click:10 Entry Time:2026-07-14 【Print】 【Close
 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation | New & Genuine Used Network Equipment Supplier 
Links:   白云搜搜   |   未来互联   |   百度   |  
Kino Technology Limited   网站技术支持:未来互联