|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
7914124616 |
ProductName: |
WS-C2950C-24 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco Catalyst WS-C2950C-24 Full English Product Description
1. Short Sales Title (For Quotation & E-commerce Listing)
Cisco WS-C2950C-24 1RU Rack-Mount Layer 2 Fast Ethernet Access Switch, 24×10/100BASE-TX RJ45 Access Ports + 2×Fixed 100BASE-FX MT-RJ Fiber Uplinks, Preloaded Enhanced IOS Image (EI), Fixed All-Copper+Fiber Chassis, Cisco Switch Clustering Supported, Wire-Speed QoS, Advanced ACL & Port Security, Ideal for Multi-Building Campus, Remote Branch, Factory LAN & Legacy Enterprise Fiber Trunk Deployments
2. Official Product Overview
The Cisco Catalyst WS-C2950C-24 is a fixed-port intelligent Layer 2 managed Fast Ethernet switch from the legacy Catalyst 2950 Series. Distinguished from base WS-C2950-24 and copper uplink WS-C2950T-24, it integrates two built-in 100BASE-FX MT-RJ multimode fiber uplink ports for long-distance inter-building trunking. This model ships factory preloaded with Enhanced Image (EI) Cisco IOS firmware, unlocking full advanced enterprise Layer 2 security, ACL, authentication and traffic management features unavailable on Standard Image (SI) copper-only variantsCisco.
Model Suffix Breakdown
-
2950: Catalyst 2950 intelligent edge managed switch series
-
24: Twenty-four fixed 10/100 auto-negotiate RJ45 copper downlink access ports
-
C: Fixed dual 100BASE-FX MT-RJ fiber uplink ports (C = Copper + Fiber fixed uplink variant)
-
Native EI Enhanced Image: Full advanced IOS feature set including 802.1X, SSH, private VLAN edge, ingress rate limiting and extended ACL support
This compact 1U metal rack-mount chassis features an internal autoranging AC power supply and front cooling fan for stable wiring closet operation. Cisco Switch Clustering technology enables unified single-IP management of multiple 2950 series switches to scale port density across multi-floor or multi-building campus networks. All RJ45 ports support auto-negotiation (10/100 speed, half/full duplex) and auto MDI-X to eliminate crossover cable requirements. The integrated MT-RJ fiber ports deliver cost-effective Fast Ethernet fiber trunking up to 2km over multimode fiber without extra GBIC/SFP modules.
Equipped with 16 MB DRAM, 8 MB flash storage and shared packet buffer memory, the WS-C2950C-24 delivers 8.8 Gbps non-blocking switching capacity and 6.6 Mpps wire-speed forwarding rate for 64-byte frames, supporting lossless concurrent voice, video and data traffic across all copper access ports and dual fiber uplinks. It adopts store-and-forward switching architecture to filter corrupted frames and prevent broadcast domain flooding.
3. Port & Hardware Specifications
-
24 × 10/100BASE-TX RJ45 auto-sensing copper access ports, auto MDI-X, IEEE 802.3x full-duplex flow control
-
2 × fixed 100BASE-FX MT-RJ multimode fiber uplink ports, 1300nm wavelength, max 2km full-duplex transmission over 62.5/125μm multimode fiber
-
1 × RJ45 RS232 serial console port for out-of-band CLI configuration
-
No modular expansion slots, all ports fixed copper/fiber design
-
Stacking capability: Cisco Switch Clustering via Fast Ethernet or FX fiber inter-switch trunk links
-
Power supply: Internal fixed autoranging AC input (100–240 VAC 50/60 Hz), max power consumption 30W
-
Rear RPS connector: Compatible with optional Cisco external redundant power supply for power failure resilience
-
Front panel LED indicators: Per-port link/activity, speed, duplex; system status, RPS power status
-
Mounting options: 19-inch 1RU rack-mount brackets included; rubber feet for standalone desktop placement
-
Thermal design: Active fan cooling, typical acoustic noise 46 dBa at 30°C ambient
-
Environmental operating range: 0°C to 45°C (32°F–113°F); storage -25°C to 70°C; relative humidity 10–85% non-condensing
-
Safety & EMI certifications: CE, FCC Class A, UL listed, VCCI Class A
-
Physical dimensions: 445 mm (W) × 44.5 mm (H, 1RU) × 242 mm (D)
-
Unit weight: 3.0 kg (6.6 lbs)
-
MAC address table capacity: Up to 8,000 MAC entries
-
MTBF: 520,000 hours under standard office operating conditions
-
Warranty: Cisco Limited Lifetime Hardware Warranty
4. Layer 2 Switching, QoS & Enhanced IOS (EI) Full Feature Set
Core Supported Features (Exclusive to EI Image)
-
Up to 64 active IEEE 802.1Q tagged VLANs, full VLAN ID range 1–1005
-
IEEE 802.1p CoS QoS with 4 egress priority queues; Strict Priority / WRR scheduling for voice/video/data classification
-
IEEE 802.3ad Fast EtherChannel static link aggregation for multi-port copper/fiber trunk bundling
-
IEEE 802.1D STP Spanning Tree Protocol + BPDU guard / Root guard to eliminate Layer 2 loops
-
Port security: Static MAC binding, sticky dynamic MAC learning, port shutdown violation mode
-
Broadcast/multicast/unicast storm control to mitigate Layer 2 flooding DoS attacks
-
SPAN port mirroring for traffic capture and network fault troubleshooting
-
IGMP Snooping v1/v2 to reduce redundant multicast bandwidth consumption for video streams
-
Voice VLAN for automatic classification and priority marking of Cisco IP Phone traffic
-
Cisco Switch Clustering for single-pane unified management of multiple clustered switches
-
RMON Groups 1,2,3,9 real-time traffic statistics monitoring
-
NTP time synchronization for consistent system log timestamps
-
CDP Cisco Discovery Protocol for automatic adjacent network device discovery
-
Web-based Cisco Device Manager & Cisco Express Setup for zero-CLI initial deployment
Advanced Exclusive EI Security & Traffic Features (Not Available on SI Models)
-
IEEE 802.1X port-based 802.1X authentication with RADIUS/TACACS+ AAA remote authentication
-
SSHv2 encrypted remote CLI management; SNMPv3 secure monitoring
-
Layer 2/Layer 3/Layer 4 access control lists (ACLs) for granular inbound traffic filtering
-
Private VLAN edge for host isolation on shared switch ports
-
Ingress port bandwidth rate limiting for traffic shaping and bandwidth control
-
Time-based ACLs for scheduled differentiated access policies
-
DSCP marking and advanced QoS reclassification for converged voice/data networks
5. Full Management Interfaces
-
Local Out-of-Band: RJ45 RS232 serial console port for direct Cisco IOS CLI access without live network connectivity
-
Secure Remote CLI: SSHv2 encrypted command-line access; fallback Telnet password authentication
-
Embedded Web GUI: Browser-based visual switch manager for port, VLAN and QoS configuration
-
SNMP v1/v2c/v3: Standard enterprise monitoring compatible with CiscoWorks, CWSI and third-party NMS platforms
-
RMON Traffic Analytics: Built-in bandwidth, error and utilization reporting for fault diagnosis and capacity planning
-
Local Storage: 8 MB onboard flash memory to store IOS operating image, startup-config and running-config files
6. Integrated Enhanced Security Suite
-
Multi-level privilege CLI access with encrypted local user password storage
-
IEEE 802.1X port authentication to validate end-user devices before network access
-
Port security to restrict unauthorized end-device MAC addresses per access port
-
STP BPDU guard and root guard to block rogue unmanaged switches from corrupting Layer 2 topology
-
Broadcast storm control to suppress flooding-based denial-of-service threats
-
Private VLAN edge to isolate connected hosts from each other on shared access ports
-
SSHv2 and SNMPv3 encryption to secure remote switch management traffic
-
Manual shutdown of unused ports to reduce unauthorized network access attack vectors
-
Dedicated management VLAN isolation to segregate switch control plane traffic from user data
7. Typical Deployment Scenarios
-
Multi-building enterprise campus access switch: 24 Fast Ethernet ports connect employee PCs, printers and Cisco IP phones; dual 100BASE-FX fiber uplinks deliver low-cost long-distance trunking between separate campus buildings
-
Remote branch office wiring closet core switch: Fiber uplinks connect back to regional headquarters over multimode fiber without expensive Gigabit transceivers
-
Manufacturing factory auxiliary LAN aggregation: Copper ports connect HMIs, PLCs and unpowered field sensors; fiber uplinks extend LAN to remote production workshops separated by large facility spaces
-
Education campus building distribution switch: Clustered multiple WS-C2950C-24 units scale student workstation port density, fiber uplinks link to campus core data center
-
Multi-location retail store aggregation: Fiber uplinks connect individual store back-office networks to regional retail headquarters over campus fiber cabling
8. Standard Package Contents
1 × Cisco Catalyst WS-C2950C-24 Fast Ethernet Switch (Enhanced IOS EI Image Preinstalled)
1 × AC power cord
1 × RJ45-to-RS232 console rollover cable
1 × 19-inch 1RU rack mounting bracket kit
Rubber desktop stand feet
Hardware installation guide & Cisco IOS configuration documentation
*External redundant power supply sold separately as optional accessory
Short Commercial Version (For Quotation & Product Catalog)
The Cisco Catalyst WS-C2950C-24 is a legacy 1RU rack-mount fan-cooled Layer 2 managed Fast Ethernet access switch from the Cisco Catalyst 2950 Series, factory preloaded with Enhanced IOS (EI) advanced feature set, equipped with 24×10/100BASE-TX non-PoE auto-sensing RJ45 copper access ports plus two fixed 100BASE-FX MT-RJ multimode fiber uplink ports, fully fixed copper+fiber chassis. It supports Cisco Switch Clustering multi-switch unified management, delivers 8.8 Gbps non-blocking switching capacity, 8K MAC address table, 802.1Q VLAN, 802.1p CoS QoS, IGMP Snooping, STP, port security, 802.1X authentication, SSHv2 and full ACL filtering. Purpose-built fiber uplink model for multi-building campus, remote branch and factory LAN fiber trunk deployments, covered by Cisco Limited Lifetime Hardware Warranty.
|
|
|
| Click:17 Entry Time:2026-07-09 【Print】 【Close】 |
|
|
|
|