|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
7171046116 |
ProductName: |
C898-K9 |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco C898EA-K9 (Short Name C898-K9) Full Product Description
1. Short Overview
C898-K9 (Official Full PID: CISCO898EA-K9)is a fanless metal Integrated Services Router Generation 2 (ISR G2) within the Cisco 890 Series, engineered for service provider carrier networks, enterprise branch offices, industrial remote sites and retail locations deployed on symmetrical multi-pair G.SHDSL leased-line copper infrastructure. This wired-only base SKU excludes embedded dual-band 802.11n Wi-Fi radio and cellular WWAN modem hardware. It integrates a 4-pair multimode G.SHDSL.bis WAN port supporting both ATM and EFM Ethernet-over-copper transport, a combo Gigabit Ethernet / hot-swappable SFP fiber redundant backup WAN slot, an 8-port full Gigabit managed LAN switch with 4 IEEE 802.3af PoE-capable ports, plus an independent ISDN BRI dial backup port for tertiary out-of-band emergency connectivity. Preloaded with permanent Cisco IOS Advanced Security K9 crypto image, it delivers dedicated hardware IPsec crypto acceleration, zone-based stateful inspection firewall, inline IPS intrusion prevention, full IPv4/IPv6 dual-stack enterprise routing and multi-layer QoS, supporting automatic multi-tier WAN failover between symmetrical G.SHDSL leased lines and fiber/copper Gigabit links for balanced upload/download secure branch networkingCisco.
Suffix Breakdown
-
C898: Leased-line native ISR G2 platform of Cisco 890 Series optimized for multi-pair G.SHDSL symmetrical copper leased circuits
-
EA: EFM + ATM dual-mode G.SHDSL chipset compliant with ITU-T G.991.2 (SHDSL.bis) and G.998.2 EFM multi-pair bonding standards
-
-K9: Permanent Cisco cryptographic license bundle enabling AES-128/AES-192/AES-256, 3DES, DES, SHA-1/SHA-2, IKEv1/IKEv2 full encryption suite with dedicated hardware crypto offload
Core Differentiators
-
vs VDSL/ADSL C896VA / C897VA Series: Those models are designed for asymmetric POTS/ISDN xDSL; C898-K9 uses symmetrical multi-pair G.SHDSL leased lines for equal upstream/downstream bandwidth for carrier-grade point-to-point links.
-
vs wireless variant C898EAW-K9: C898-K9 omits integrated dual-band 802.11n MIMO WLAN radio; wireless SKUs add built-in wireless access point for on-site mobile client coverage.
-
vs Ethernet-only expandable C892FSP-K9: C892FSP-K9 has no integrated G.SHDSL modem; C898-K9 provides native 4-pair bonded symmetrical G.SHDSL primary WAN plus combo SFP/GE fiber-copper backup dual broadband redundancy.
-
vs entry-level metal C888-K9: C888-K9 only features Fast Ethernet LAN, smaller memory and limited concurrent VPN tunnel capacity; C898-K9 upgrades to full 8-port Gigabit PoE switching, 1 GB DRAM, native inline IPS, DMVPN dynamic VPN and complete EIGRP/BGP enterprise routing stack.
-
vs industrial hardened C819HG series: C898-K9 is commercial fanless metal desktop chassis with standard indoor temperature range, not certified for vehicle, railway or extreme outdoor shock/vibration environments.
2. Hardware Interface & Performance Specifications
Dual Primary/Backup WAN Interfaces (Automatic Failover Supported)
-
Integrated 4-Pair Multimode G.SHDSL.bis WAN Port (Dual ATM / EFM Mode)
Supports 1/2/4-pair copper bonding for symmetrical leased-line bandwidth, auto-selectable ATM PTM or EFM Ethernet encapsulation, fully compliant with ITU G.991.2 and G.998.2. Built-in SHDSL OAM line monitoring, seamless rate adaptation, loop diagnostics and Dying Gasp fault detection, ideal for carrier symmetrical point-to-point backhaul linksCisco.
-
Combo GE/SFP Hot-Swappable Gigabit WAN Slot
Dual-purpose shared port supporting either copper RJ45 Gigabit Ethernet or hot-pluggable GE SFP transceivers (SX/LX/ZX), serving as independent high-bandwidth fiber/copper redundant backup transport path.
Tertiary ISDN BRI Dial Backup Port
Dedicated ISDN BRI S/T RJ45 dial backup port, activated only when both G.SHDSL leased-line and combo SFP/GE WAN links simultaneously fail to provide out-of-band emergency connectivity.
8-Port Full Gigabit Managed LAN Switch Interfaces
-
Ports 1–4: IEEE 802.3af PoE capable (requires mandatory 125W high-power universal AC adapter to deliver 15.4W per port for IP cameras, VoIP phones and external wireless APs)
-
Ports 5–8: Standard non-PoE Gigabit Ethernet
-
Full switch feature set: 802.1Q VLAN tagging, port isolation, static MAC security, dedicated DMZ port assignment, broadcast storm control, SPAN port monitoring, LACP link aggregation, Smartport macros and per-port CoS traffic marking
Management & Auxiliary Ports
-
Separate dedicated RJ45 Console port: Independent local CLI configuration via rollover cable, physically separated from AUX port
-
Independent RJ45 AUX port: Standalone secondary serial port for extra out-of-band remote management access
-
Single USB 2.0 Type-A host port: External flash storage for log archiving, offline configuration backup and EEM script automation extensions
-
Hardware reset button, Kensington anti-theft lock slot for physical equipment protection
-
Onboard real-time clock (RTC) for accurate timestamping of logs, security certificates and network event triggers
Memory & Storage
-
DRAM: 1 GB base system memory to process dozens of concurrent IPsec VPN tunnels, dual-stack routing, inline IPS inspection, PoE LAN forwarding and bonded G.SHDSL leased-line trafficCisco Russ...
-
Flash storage: 256 MB onboard flash; factory preloadedc890-universalk9-mzAdvanced Security IOS image, minimum supported firmware release 15.4(2)T
Front Panel LED Status Indicators
Visual status LEDs for system power/fault alarm, multi-pair G.SHDSL line sync/training status, combo SFP fiber/copper GE WAN link activity, ISDN BRI dial backup operational state, PoE power delivery indicator, and individual link/rate LEDs for all eight Gigabit LAN ports for fast on-site troubleshooting without CLI login.
Physical & Power Parameters
-
Form factor: Fanless all-metal compact desktop chassis, optional wall-mount bracket available
-
Dimensions (H × W × D): 44.5 mm × 322.8 mm × 248.4 mm (1.75 × 12.7 × 9.78 inches) with anti-slip rubber feet
-
Weight: ~2.5 kg (5.5 lbs) without power supply
-
Two official power supply options
-
60W universal AC adapter (for non-PoE deployments, 12 VDC output)
-
125W high-power universal AC adapter (mandatory if PoE LAN ports are utilized)
-
Typical maximum power consumption: 26 W under full 4-pair G.SHDSL + combo SFP fiber + all 8 Gigabit PoE LAN ports full load
-
Ingress protection: IP20, only suitable for dry indoor commercial office environments
Environmental Operating Specifications
-
Operating temperature: 0°C ~ +40°C (32°F ~ 104°F); performance derates 1.5°C per 1000m altitude above 3000m
-
Storage temperature: -20°C ~ +65°C (-4°F ~ 149°F)
-
Relative humidity: 10%–85% RH non-condensing
-
Maximum operating altitude: 3,000 m (10,000 ft)
3. Hardware Acceleration & Security Engine
-
Dedicated onboard crypto co-processor fully offloads IPsec VPN encryption traffic and eliminates CPU bottlenecks under up to 50 concurrent site-to-site and remote access VPN tunnels
-
Permanent K9 crypto license unlocks complete enterprise encryption stack: DES, 3DES, AES-128/192/256, SHA-1/SHA-2 hash algorithms, IKEv1/IKEv2 static site-to-site tunnels, Easy VPN remote access and DMVPN hub-spoke dynamic tunnels
-
Integrated G.SHDSL traffic isolation filters to segregate symmetrical leased-line copper loop traffic and protect internal corporate LAN via independent VLAN segmentation
4. Cisco IOS Advanced Security Feature Suite
Multi-Tier WAN Routing & Redundancy (G.SHDSL Leased-Line + Combo Fiber/GE)
-
Cisco Express Forwarding (CEF), static routing, RIPv1/v2, OSPF, EIGRP, BGP, GRE/MGRE tunnel encapsulation, complete IPv4/IPv6 dual-stack support
-
Automatic policy-based failover logic between primary multi-pair bonded G.SHDSL (ATM/EFM) leased-line and secondary combo SFP/GE fiber-copper backup link
-
ISDN BRI tertiary dial backup triggered upon simultaneous failure of both main WAN uplinks
-
Policy-Based Routing (PBR), multi-NAT pools, PAT overload for logical segmentation of PoE-powered devices and standard wired LAN endpoints
-
DHCP server/relay/client, DNS proxy, dynamic DNS, Ethernet OAM / 802.3ah for fiber/copper link health monitoring; dedicated SHDSL OAM for multi-pair copper leased-line diagnostics
Unified Enterprise Security Suite
-
Zone-Based Stateful Policy Firewall (ZBFW) for logical isolation of internal corporate LAN, PoE camera/VoIP subnet, DMZ and untrusted internet traffic zones
-
Dynamic Multipoint VPN (DMVPN), Easy VPN Server & Client, IKEv2 IPsec encrypted inter-branch tunnels operable over G.SHDSL leased-line, copper GE or SFP fiber transport
-
Signature-based inline Intrusion Prevention System (IPS), Cisco ScanSafe cloud URL filtering, deep NBAR application control for HTTP, FTP, IM and mainstream business applications
-
AAA authentication via TACACS+ / RADIUS, 802.1X port authentication available on all 8 Gigabit LAN switch ports
-
Secure management only: SSHv2, HTTPS; plaintext Telnet disabled by factory default
-
Granular access control lists (ACLs), static MAC address port lockdown on Gigabit switch ports
QoS & Symmetrical Leased-Line/Gigabit Bandwidth Optimization
-
WFQ, CBWFQ, LLQ queuing mechanisms for low-latency prioritization of voice, video surveillance, SCADA and POS real-time payment traffic
-
NBAR deep packet inspection to classify and prioritize symmetrical workloads (bidirectional video backhaul, inter-site file replication, industrial SCADA data) leveraging balanced G.SHDSL upload/download bandwidth
-
RTP/TCP header compression, SHDSL traffic shaping and policing to control metered leased-line bandwidth consumption and avoid overage charges
-
PoE QoS scheduling to guarantee stable power and bandwidth priority for critical IP cameras and VoIP handsets
Remote Management & Automation
-
Zero-Touch Provisioning (ZTP) for mass standardized deployment of enterprise branches and ISP G.SHDSL managed CPE
-
Cisco IOS Embedded Event Manager (EEM): Scriptable triggers for SHDSL line drop, fiber link loss and automatic ISDN dial backup activation with alert notifications
-
SNMP v2c/v3, remote syslog, IP SLA end-to-end link performance monitoring, dedicated MIBs for SFP fiber diagnostics and multi-pair G.SHDSL copper loop telemetry
-
Compatible with Cisco Configuration Professional (CCP) web GUI for simplified CLI-free deployment and daily monitoring of routing, security, PoE, fiber and SHDSL subsystems
-
GOLD non-disruptive onboard diagnostics for continuous remote hardware health checks of SHDSL modem, SFP fiber, copper Ethernet and PoE subsystems
5. Typical Deployment Scenarios
-
Carrier Symmetrical G.SHDSL Multi-Redundant Secure Gateway with PoE
Primary 4-pair bonded G.SHDSL leased-line delivers balanced upload/download bandwidth for inter-branch replication and multi-camera video backhaul; combo SFP fiber/GE copper serves as high-speed redundant backup. The 8-port Gigabit PoE LAN switch powers POS payment terminals, office PCs, VoIP phones and high-resolution IP camera arrays. VLAN segmentation separates sensitive payment infrastructure from staff corporate LAN and public internet threats. Persistent IPsec DMVPN tunnels transmit large volumes of symmetrical business data securely back to corporate headquarters, while zone firewall + inline IPS block external network intrusion risks.
-
Mission-Critical Industrial Satellite Office Symmetrical Leased-Line Router
Three-layer WAN redundancy (G.SHDSL symmetrical primary, fiber/GE secondary, ISDN BRI tertiary dial backup) meets strict enterprise business continuity requirements. Full Gigabit PoE switching eliminates separate power injectors for cameras and VoIP devices, with full EIGRP/BGP support for seamless integration into the corporate core routing domain. Ideal for industrial sites requiring equal bidirectional data throughput for SCADA monitoring and remote control.
-
Service Provider Managed G.SHDSL Business CPE
Uniform hardware platform enables ISPs to deliver either multi-pair bonded G.SHDSL symmetrical leased-line or SFP fiber/copper Metro Ethernet services to enterprise subscribers requiring balanced bidirectional bandwidth. Centralized ZTP mass deployment and remote SNMP monitoring support managed security, PoE and high-bandwidth networking service packages.
-
Campus Remote Building PoE IoT & Surveillance Edge Router
PoE ports connect multiple high-resolution IP cameras, access control hardware and environmental sensors requiring equal upload/download video backhaul; combo SFP fiber uplink provides high-throughput backhaul to the campus core. Automatic copper GE failover ensures uninterrupted sensor and video data transmission during fiber outages, while G.SHDSL leased-line acts as primary symmetrical connectivity for locations without full fiber coverage.
-
Symmetrical Leased-Line Teleworker Small Office VPN Gateway
Deployed at remote enterprise sites serviced by carrier G.SHDSL copper circuits, the symmetrical DSL profile supports bidirectional large file replication, multi-party video conferencing and remote industrial monitoring workloads. Encrypted Easy VPN tunnels maintain stable secure connectivity to corporate headquarters, PoE ports power local IP cameras and VoIP equipment, and integrated security services defend all wired Gigabit endpoints against malware and unauthorized access.
6. Standard Package Contents of C898-K9 (CISCO898EA-K9)
1 × Cisco C898EA-K9 fanless wired Integrated Services Router (no Wi-Fi radio or cellular modem hardware)
Wall mounting hardware kit
Hardware installation guide, global safety, EMC and RoHS compliance documentation
Preloaded Cisco IOS Advanced Security K9 encrypted firmware stored in internal flash
Separately Sold Optional Accessories
-
RJ45 rollover console cable for local CLI configuration
-
GE SFP fiber transceivers (SX/LX/ZX) for combo fiber WAN uplink
-
Multi-pair G.SHDSL copper leased-line cord, ISDN BRI telephone line cord for dial backup
-
60W non-PoE AC power supply / 125W high-power PoE AC power supply
-
Spare replacement universal AC power adapter
-
USB flash drives for log archiving and offline configuration backup
-
CAT5e/CAT6 Ethernet patch cords for LAN and copper GE WAN connections
Software Licensing Information
-
The-K9suffix includes a permanent built-in cryptographic license; no extra purchase required for IPsec, AES encryption and secure management protocols
-
All core routing, multi-layer G.SHDSL/fiber failover, SHDSL OAM line management, PoE power control, firewall, inline IPS, QoS, ZTP and Gigabit managed switch features are fully included in the base Advanced Security IOS image; no additional paid feature licenses needed
-
No wireless AP or cellular modem licenses apply (corresponding hardware is omitted from this wired symmetrical leased-line SKU)
Short Commercial Catalog Summary for Quotation
Cisco C898-K9 (official PID CISCO898EA-K9) is a fanless metal wired-only ISR G2 from the Cisco 890 Series, designed for carrier symmetrical G.SHDSL leased-line infrastructure small enterprise branches, industrial remote sites and service provider managed CPE requiring 4-pair bonded multi-mode ATM/EFM G.SHDSL symmetrical primary transport, combo hot-swappable SFP fiber + copper Gigabit redundant backup WAN, independent ISDN BRI tertiary dial backup, and an integrated 8-port full Gigabit managed LAN switch with 4 IEEE 802.3af PoE-capable ports. Equipped with 1 GB DRAM / 256 MB flash storage, dedicated hardware IPsec crypto acceleration and permanent K9 cryptographic licensing, it delivers multi-layer automatic WAN failover, symmetrical G.SHDSL line OAM management, zone-based stateful firewall, inline IPS threat prevention, DMVPN/IKEv2 IPsec site-to-site tunnels, enterprise dual-stack routing and zero-touch provisioning. The compact fanless metal desktop chassis supports optional wall mounting and standard indoor commercial operating environments, compatible with Cisco Configuration Professional for unified remote network lifecycle management. This model excludes embedded Wi-Fi and cellular WWAN hardware to reduce procurement costs for pure wired symmetrical leased-line branch sites requiring balanced bidirectional bandwidth, high-speed Gigabit switching and PoE device powering. Limitations include no native wireless failover capability, PoE operation requires a separate 125W high-power power supply, and operation is restricted to dry indoor office environments. The router complies with UL, IEC, EMC and RoHS global regulatory standards for 24/7 mission-critical secure symmetrical leased-line medium-branch network operation.
|
|
|
| Click:13 Entry Time:2026-07-17 【Print】 【Close】 |
|
|
|
|